MAURY USCG vessel records Sign in
← All vessels

KIRBY 27757

KIRBY 27757 is a 2009 tank barge. The Coast Guard has recorded 19 inspections since 2009, most recently in November 2024, along with 2 deficiencies and 2 casualty investigations between 2010 and 2017.

Records from 2009 to 2024. Most recent: inspection, 7 November 2024.

Built
2009
Last inspected
7 November 2024
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

987887
Flag
UNITED STATES
—
Maury page id
psix-987887

Inspections, by type

…with no type recorded3
Years with a record 10 calendar years (2009–2024)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)300.0 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,632 / net 1,632
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS INC · ASHLAND CITY, TN, UNITED STATES · built 2009
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portWILMINGTON, DE
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 22 January 2026 · expires 28 February 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1632 - Simplified, Gross Ton
1632 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 5

Inspection history · 19

7 November 2024 Examination of Repairs · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8031929
18 April 2024 COI Inspection · Examination of Repairs · Internal Structural Exam · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7894222
7 March 2019 MTSA Verification · COI Inspection · Internal Structural Exam · Cargo Tank Internal · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6633933
27 December 2017 Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6353270
8 October 2017 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6288875
14 January 2017 Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6070944
11 December 2015 Examination of Repairs · Periodic Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5779782
17 December 2014 MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5142198
10 January 2014 MTSA Verification · Administrative Inspection · Internal Structural Exam · COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4780745
25 July 2013 Administrative Inspection · Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4664148
18 July 2013 Damage Survey · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4657812
7 December 2012 MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4563932
3 February 2012 Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4297472
25 August 2011 Administrative Inspection
Administrative · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 4126966
25 June 2010 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3776109
13 March 2010 Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3697572
22 January 2010 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3668334
12 February 2009 Deficiency Check · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3416863
26 January 2009 Administrative Inspection · Initial Certification · MTSA Verification · Initial Construction-Excluding Oversight · Cargo Tank Internal · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3400322

Deficiency record · 2

Deck/Cargo › Holds/Tanks › Bulkhead
Issued 18 July 2013 Resolved
Pinhole size leak discovered on #3 Port Side cargo tank top on the actual plate (not the welds). Barge is fully loaded with #6 oil and the leak estimated to be 01 tablespoon. Fully discharge and proceed immediately to shipyard w/in COTP to complete permanent repairs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 July 2013
Resolved 25 July 2013
Resolution: Witnessed air soap test of tank-top insert under 1.5 psig, test SAT. See narrative.
Construction/Loadline › Hull › Bottom Plating
Issued 6 February 2009 Resolved
Upset in knuckle and floor frame.
Action required: 705 - Other - as specified
Resolved 12 February 2009
Resolution: Air/soap tested damaged area, inspected internals in affected area. All sat.

Casualty record · 2

25 June 2010Routine · role: Moored/Anchored in Vicinity of Primary Subject · activity 3776109
8 October 2017Routine · role: Acknowledged Pollution Source · activity 6288875
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.