MAURY USCG vessel records Sign in
← All vessels

RTC 84

RTC 84 is a 2009 tank barge. The Coast Guard has recorded 34 inspections since 2010, most recently in May 2026, along with 12 deficiencies and 5 casualty investigations between 2010 and 2024.

Records from 2010 to 2026. Most recent: inspection, 19 May 2026.

Built
2009
Last inspected
19 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCX3683
994265
Flag
UNITED STATES
—
Maury page id
psix-994265

Inspections, by type

…with no type recorded4
Years with a record 16 calendar years (2010–2026)
The 34 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)326.5 ft × 74.0 ft × 26.5 ft
Registered tonnagegross 5,544 / net 5,544
ITC dimensions (L × B × D)326.5 ft × 74.0 ft × 26.5 ft
ITC tonnagegross 5,906 / net 3,857
BuilderSENESCO MARINE · NORTH KINGSTOWN, RI, UNITED STATES · built 2009
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 10 September 2025 · expires 31 October 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it5906 - Convention (Subpart B), Gross Ton
13663 - Displacement, Gross Ton
11283 - Dead Weight, Gross Ton
5544 - Regulatory (Subpart C or D), Gross Ton
3857 - Convention (Subpart B), Net Ton
5544 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 3

Inspection history · 34

19 May 2026 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8376092
1 November 2025 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8261720
29 April 2025 MARPOL Annex II Examination · COI Inspection · MTSA Verification · MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8103907
26 November 2024 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8040742
23 September 2024 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8001504
4 August 2024 Bulk Liquid Transfer Monitor
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8044262
6 June 2024 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7927799
16 June 2023 MTSA/ISPS Verification · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7716681
3 August 2022 Periodic Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7524535
1 August 2022 Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7522200
8 March 2021 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7151948
27 May 2020 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6961576
16 March 2020 Examination of Repairs · COI Inspection · DAPI Audit · Administrative Inspection · Construction Oversight · MTSA Verification
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6946655
2 December 2019 Cargo Tank Internal · Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6865276
15 November 2018 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6584132
11 May 2018 Examination of Repairs · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6415983
16 November 2017 Annual Inspection · Damage Survey · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6308126
10 November 2017 Damage Survey
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6306000
8 November 2017 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6303983
24 July 2017 Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6219984
30 January 2017 MARPOL Annex I Examination · MTSA/ISPS Verification · Periodic Inspection · MARPOL Annex VI Survey · MARPOL Annex II Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6079339
2 December 2016 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6051651
2 March 2016 MARPOL Annex I Examination · MARPOL Annex II Examination · MARPOL Annex VI Survey · Annual Inspection · MTSA Verification
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5825478
4 January 2016 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5790755
10 November 2014 Examination of Repairs · MTSA Verification · Internal Structural Exam · COI Inspection · MARPOL Annex II Examination · MARPOL Annex I Examination · Hull Examination · MARPOL Annex VI Survey
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5017543
3 September 2013 MTSA Verification · MARPOL Annex II Examination · Annual Inspection · MARPOL Annex VI Survey · Cargo Tank Internal · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4699234
1 July 2013 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4640848
18 October 2012 MARPOL Annex I Examination · Periodic Inspection · MARPOL Annex VI Survey · MTSA Verification · MARPOL Annex II Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4456351
31 October 2011 Annual Inspection · MARPOL Annex VI Survey · MARPOL Annex I Examination · MARPOL Annex II Examination · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4179240
11 October 2011 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4165785
15 February 2011 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3945929
25 January 2011 MARPOL Annex I Examination · MARPOL Annex II Examination · MARPOL Annex VI Survey · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3930506
9 August 2010 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3826123
30 April 2010 Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3736488

Deficiency record · 12

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 November 2025 Resolved
If... damage or deterioration to the hull plating, structural members, or cargo tanks is discovered, the Officer in Charge, Marine Inspection, may require the vessel to be drydocked or otherwise taken out of service to further assess the extent of the damage and to effect permanent repairs. Vessel was involved in a collision on the starboard side to include the forepeak and along the exterior of the 1, 3, and 5 ballast tanks with unknown damage to hull. Vessel is required to be taken out of service and restricted in movement until a satisfactory damage assessment is conducted. Provide a satisfactory diver report and damage assessment survey in order to determine any necessary plans for repair. 46 CFR 31.10-21(c)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 1 November 2025
Resolution: ABS Damage Survey and Diver Report Received.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 23 September 2024 Resolved
No extensive alterations involving the safety of a tank vessel either in regard to hull or machinery shall be made without the approval of the Commandant. Before such alterations are carried out, copies of plans and specifications in triplicate for the work involved shall be submitted. Plan G&C Dwg. No. P-11, Rev. 3, "Hydraulic Piping", dated June 21, 2024 needs to be resubmitted to include the valves, demonstrating compliance with 46 CFR 56.20. See USCG Marine Safety Center letter E1-2403646, dated October 9, 2024 for reference.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 December 2024
Resolved 6 December 2024
01 - Certificates & Documentation › 013 - Documents › Shipboard marine pollution emergency plan for NLS
Issued 6 June 2024 Resolved
Every ship of 150 gross tonnage and above certified to carry noxious liquid substances in bulk shall carry on board a shipboard marine pollution emergency plan for noxious liquid substances. Shipboard marine pollution emergency plan (SMPEP) was not present during inspection. SMPEP must be approved and carried onboard prior to carrying Annex II cargo.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 June 2024
Resolved 7 June 2024
Resolution: Received cover letter for SMPEP.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 6 June 2024 Resolved
The NOx Technical Code 2008 shall be applied in the certification, testing and measurement procedures for the standards set forth in this regulation. Vessel did not have engine technical file for all generators onboard or EIAPP.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2024
Resolved 19 December 2024
Resolution: Vsl provided technical files for generator engines.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 6 June 2024 Resolved
The ring, lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. Observed missing paint on the load line markings. Rectify prior to credit drydock.
Action required: 705 - Other - as specified
Due 6 June 2024
Resolved 16 October 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 June 2023 Resolved
All exposed and dangerous places such as gears and machinery shall be properly protected with covers, guards or rails in order that the danger of accidents may be minimized. Both electrical generators have an exposed pulley on the motor for the radiator fan. Retrofit guards.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2023
Resolved 27 June 2023
Resolution: Operator sent photos of rectified deficiency. All sat. See Documents tab under Deficiencies for photos.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 8 March 2021 Resolved
A pressure gage shall be installed for each pump discharge, and it shall be located at a point visible with respect to the pump controls. STBD cargo pump gauge was not visible from operating station. Move gauge to a location where it can be seen from control station. 46CFR 32.50-5 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2021
Resolved 12 March 2021
Construction/Loadline › Structures › Deck Plating
Issued 16 November 2017 Resolved
Effect repairs in kind to port bow and surrounding areas damaged due to collision on 10NOV2017 while transiting via LIS.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 December 2017
Resolution: Vessel repaired all damaged structures to the satisfaction of attending MI and ABS surveyor.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 25 January 2011 Resolved
Starboard Prime Mover has a fuel leak on the fuel supply line. Replace/renew with new approved hose.
Action required: 705 - Other - as specified
Due 24 February 2011
Resolved 15 February 2011
Resolution: Vessel replaced angle drive shaft seal.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 25 January 2011 Resolved
Starboard Prime Mover shaft is leaking hydraulic oil. Investigate cause and repair/replace.
Action required: 705 - Other - as specified
Due 24 February 2011
Resolved 15 February 2011
Resolution: Vessel discovered old angle drive shaft seal had minor play in shaft. Vessel replaced angle drive shaft seal.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 25 January 2011 Resolved
Port and Starboard breaker boxes have multiple breakers not labeled correctly or lack correct labels altogether. Determine what the incorrect or improper breakers go to and update "panel board circuit directory cardholder". 46 CFR 111.40-11
Action required: 705 - Other - as specified
Due 24 February 2011
Resolved 15 February 2011
Resolution: Vessel updated breaker boxes with correct labeling.
Accommodation/Occupational Safety › Heating › Electric Air Heating Equipment
Issued 25 January 2011 Resolved
Determine if office heaters are of approved type. Current Dayton brand overhead heaters (2) do not have a thermal cutout of the manually-reset type as required by regulation, among other questionable UL requirements. 46 CFR 111.87-3 (c).
Action required: 705 - Other - as specified
Due 24 February 2011
Resolved 15 February 2011
Resolution: Heater was found to be in compliance with UL. Vessel has posted the specs on the heater for future inspection.

Casualty record · 5

9 August 2010Routine · role: Transiting Vicinity of Primary Subject · activity 3826123
12 March 2013Routine · role: Involved in a Marine Investigation (non-casualty) · activity 4549248
1 July 2013Routine · role: Involved in a Marine Investigation (non-casualty) · activity 4640848
8 November 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 6303983
26 November 2024Routine · role: Transiting Vicinity of Primary Subject · activity 8040742
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record