MAURY USCG vessel records Sign in
← All vessels

JAN MORAN

JAN MORAN is a 2010 towing vessel. The Coast Guard has recorded 20 inspections since 2011, most recently in January 2026, along with 5 deficiencies, 1 operational control and 4 casualty investigations between 2012 and 2025.

Records from 2011 to 2026. Most recent: inspection, 3 January 2026.

Built
2010
Last inspected
3 January 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9612105 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDM7618
1080825
Flag
UNITED STATES
367464170, 368235760
Maury page id
psix-1080825

Inspections, by type

…with no type recorded8
Years with a record 11 calendar years (2011–2026)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)93.0 ft × 40.0 ft × 22.2 ft
Registered tonnagegross 194 / net 132
ITC dimensions (L × B × D)93.0 ft × 40.0 ft × 22.2 ft
ITC tonnagegross 414 / net 124
BuilderICE FLOE LLC · FREELAND, WA, UNITED STATES · built 2010
Hull materialSteel
PropulsionDiesel
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portWILMINGTON, DE
Trade endorsementsCoastwise, charter, Registry
DocumentationValid · issued 3 March 2026 · expires 28 February 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it414 - Convention (Subpart B), Gross Ton
194 - Regulatory (Subpart C or D), Gross Ton
321 - Dead Weight, Ton
817 - Displacement, Ton
124 - Convention (Subpart B), Net Ton
132 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDM7618MMSI 368235760 · active · compulsorily equipped · granted 21 January 2022, expires 21 January 2032
WDL9582MMSI 367464170 · active · compulsorily equipped · granted 2 February 2021, expires 2 February 2031
WDF5519MMSI 367464170 · expired · compulsorily equipped · granted 19 August 2010, cancelled 24 October 2020
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 9

Inspection history · 20

3 January 2026 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8289693
11 August 2025 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8259257
24 August 2023 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7776661
15 August 2023 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7769098
31 July 2023 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7758771
2 February 2023 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7630994
6 December 2022 COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7604175
22 August 2022 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7540779
1 December 2021 MARPOL Annex VI Survey · MARPOL Annex I Examination · Ballast Water Examination · Exemption · MARPOL Annex IV Survey · Administrative Inspection · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7367585
26 May 2021 Deficiency Check · Initial Certification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7206379
30 December 2020 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7117959
28 July 2019 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6959277
5 June 2019 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6709790
8 August 2018 Bulk Liquid Transfer Monitor
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6587499
11 July 2018 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6476087
23 April 2018 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6397808
14 August 2013 MTSA Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4686037
16 July 2012 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4380846
24 May 2012 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4329937
20 January 2011 MTSA Verification · Industry Initiated Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 3930510

Deficiency record · 5

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 3 January 2026 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Vessel lost propulsion in one z-drive while underway. 46 CFR 143.205(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 January 2026
Resolved 3 January 2026
Resolution: Received ABS report
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 13 December 2021 Resolved
The master must ensure that all lifesaving equipment is properly maintained and ready for use at all times. Vessel's liferaft discovered past due for required annual servicing. 46 CFR 141.230
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 December 2021
Resolution: Received servicing report for liferaft and verified documentation that liferaft was properly installed on board vessel.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 13 December 2021 Resolved
All portable fire extinguishers, semi-portable fire-extinguishing systems, fire detection systems, and fixed fire-extinguishing systems, including ventilation, machinery shutdowns, and fixed fire-extinguishing system pressure-operated dampers on board the vessel, must be inspected or tested at least once every 12 months. Vessel's portable fire extinguishers and fixed fire-extinguishing system discovered past due for required annual servicing. 46 CFR 142.240(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 December 2021
Resolution: Verified required servicing documentation attesting to serviced fixed and portable fire-extinguishing systems.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 3 June 2021 Resolved
All safety and relief valves for use on pressure vessels shall be designed to meet the protection and service requirements for which they are intended and shall be set to relieve at pressure which does not exceed the "maximum allowable working pressure". MI observed the pressure relief valve is set higher the the MAWP.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2021
Resolved 15 June 2021
Resolution: New relief safety pressure valve installed on 02 air receivers and has PSI set to 250.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 May 2021 Resolved
Each towing vessel must be operated in compliance with 33 CFR parts 101 and 104, as applicable. MI did not see a valid security plan on board. Vessel must have a security plan on board.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2021
Resolved 15 June 2021
Resolution: Verified an active Vessel Security Plan on board, vessel had documentation of an Alternative Security Plan. Meets regulations

Casualty record · 4

24 May 2012Routine · role: Transiting Vicinity of Primary Subject · activity 4329937
28 July 2019Routine · role: Transiting Vicinity of Primary Subject · activity 6959277
31 July 2023Routine · role: Involved in a Marine Investigation (non-casualty) · activity 7758771
11 August 2025Routine · role: Transiting Vicinity of Primary Subject · activity 8259257
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

DELTA LINDSEY (2012–2019). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.