Documentation record
Registered dimensions (L × B × D)75.9 ft × 27.0 ft × 7.9 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRAYCO SHPBUILDERS & REPAIRS INC · BOURG, LA, UNITED STATES · built 1978
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORTSMOUTH, VA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 2 December 2025 · expires 31 December 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 44
11 August 2025
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8207370
11 August 2025
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8259257
30 June 2025
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8170348
19 March 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8095113
13 March 2025
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8084567
15 April 2024
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7893420
9 May 2023
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7684691
24 March 2023
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7656500
20 October 2022
Deficiency Check · Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7581096
14 January 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7379103
14 January 2021
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7124300
14 December 2020
Type not recorded
No type recorded · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7113838
18 October 2019
Initial Certification · Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6852303
25 June 2019
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6767162
9 August 2017
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6237378
17 July 2017
Industry Initiated Exam · MTSA Verification · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6212166
28 October 2014
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5014130
23 February 2012
Administration
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4249495
14 July 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3274560
7 May 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3200668
2 May 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3337753
4 April 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3179748
26 October 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3087840
17 October 2007
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3081485
14 November 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2835217
5 November 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2814762
2 June 2003
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1923179
17 May 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1633137
16 October 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 138869
14 October 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 136603
4 April 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 186981
25 April 1998
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 147785
10 December 1997
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1114506
8 August 1997
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1455507
6 August 1997
MARPOL Annex V Examination · Uninspected Towing Vessel
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1118568
3 August 1997
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 111352
22 May 1997
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 5107
12 November 1996
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 12399
31 July 1995
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 135835
18 February 1994
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 674335
2 March 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 644895
11 November 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 7627
11 November 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 212397
20 December 1990
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 920867
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 13 March 2025
Resolved
Storage of flammable or combustible products; (d) A 40-B portable fire extinguisher must be located near the storage room or cabinet. This is in addition to the portable fire extinguishers required by tables 142.230(a) and 142.230(b) of this part. No 40-B portable fire extinguisher was located near the Flammable Storage cabinet.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2025
Resolved 19 March 2025
Resolution: Fire extingusher installed at Flamm Locker
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 March 2023
Resolved
Extension cords must not be used as a permanent connection to a source of electrical power.
Extension cord was permanently fixed as power supply for MSD control panel.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2023
Resolved 6 April 2023
Resolution: Removed Extension cord, replaced with hard wire.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 March 2023
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards.
Breaker panel in galley found with missing blanks.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2023
Resolved 6 April 2023
Resolution: Added blanks to galley panel.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 March 2023
Resolved
A towing vessel may not be operated without having onboard a valid COI issued by the Coast Guard.
46CFR136.200
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 March 2023
Resolution: Vessel obtained valid COI after sat COI inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 14 January 2022
Resolved
46 CFR 141.385(b)
Each towing vessel operating in oceans and coastwise service must have a line throwing appliance approved under 160.040 series. The line throwing appliance must have an auxiliary line of at least 1500 feet with a breaking strength of 9000 pounds-force. Vessel does not have auxiliary line for line throwing devices.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2022
Resolved 18 February 2022
Resolution: Vessel provided auxiliary line.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 14 January 2022
Resolved
46 CFR 144.605
Means shall be provided for closing in case of a fire each annular space around funnels. Vessel does not have a means to cover/close port and starboard openings on funnel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2022
Resolved 18 February 2022
Resolution: Vessel provided closings.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 14 January 2022
Resolved
Each towing vessel operating in oceans and coastwise service must have a line throwing appliance approved under approval series 160.040. 160.040-4 requires 04 rocket projectiles (two shall be of the buoyant type) and 04 service lines. Vessel has 02 complete line throwing appliances and is required 04.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2022
Resolved 18 February 2022
Resolution: Vessel provided 02 complete line throwing appliance's.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 January 2021
Resolved
Each life jacket must be marked in block capital letters with the name of the vessel. Life jackets on-board are not marked with the vessels current name.
46CFR141.340(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 February 2021
Resolved 29 January 2021
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 19 January 2021
Resolved
Immersion suits are required at each watch station. Immersion suit required for upper pilot house is not serviceable.
46CFR141.350(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 February 2021
Resolved 29 January 2021
10 - Safety of Navigation › N/A - No Subsystem › Navigation bridge visibility
Issued 19 January 2021
Resolved
Windows at operating station must provide a clear field of vision for safe operation. STBD front window at the operating station is cracked.
46CFR144.905(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 February 2021
Resolved 29 January 2021
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 January 2021
Resolved
Electrical systems must be designed and maintained to provide for safe operations of the vessel. Dead end and improperly spliced wires were found in multiple locations: Under operating station on the bridge, and near the high bilge alarm in the engine room.
46CFR143.205(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 February 2021
Resolved 29 January 2021
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 January 2021
Resolved
A fixed fire pump must be capable of 50psi and 80gpm. Fire pump was unable to provide appropriate pressure.
46CFR142.325(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 February 2021
Resolved 29 January 2021
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 January 2021
Resolved
Each vessel must have a fire -detection system installed. Crew unable to show operation.
46CFR142.330
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 February 2021
Resolved 29 January 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 January 2021
Resolved
Pressure vessel relief valves must be tested twice every 5 years, with no more than 3 years elapsing. Crew was unable to show proper operation of relief valve.
46CFR143.300(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 February 2021
Resolved 29 January 2021
11 - Life Saving Appliances › N/A - No Subsystem › Evaluation, testing and approval
Issued 19 January 2021
Resolved
Crew must demonstrate ability to recover persons from the water. Crew must perform a man over board drill with CG inspectors present.
46CFR137.200(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 February 2021
Resolved 29 January 2021
Documentation
Issued 6 August 1997
Resolved
provide the crew's licenses and mmd's for examination, presently not on board the vessel.
Condition: Unknown
Due 6 August 1997
Resolved 6 August 1997
Documentation
Issued 6 August 1997
Resolved
provide and post a copy of the vessel's waste management plan, presently missing.
Condition: Unknown
Due 6 August 1997
Resolved 6 August 1997
Documentation
Issued 6 August 1997
Resolved
provide the radio operator's permit for examination, presently not on boardthe vessel. (master&Mate).
Condition: Unknown
Due 6 August 1997
Resolved 6 August 1997
Lifesaving
Issued 6 August 1997
Resolved
mark or stencil the vessel's name on all pfd's presently missing.
Condition: Unknown
Due 6 August 1997
Resolved 6 August 1997
Documentation
Issued 6 August 1997
Resolved
provide tow wire log and wire specifications for examination, presently noton board the vessel.
Condition: Unknown
Due 6 August 1997
Resolved 6 August 1997
Lifesaving
Issued 6 August 1997
Resolved
provide a copy of the servicing report for the inflatable life raft, presently not on board the vessel.
Condition: Unknown
Due 6 August 1997
Resolved 6 August 1997
Fire Fighting
Issued 6 August 1997
Resolved
provide a copy of the portable fire extinguisher servicing report for examination, presently not on board the vessel.
Condition: Unknown
Due 6 August 1997
Resolved 6 August 1997
Lifesaving
Issued 6 August 1997
Resolved
mark or stencil the vessel's name on ring buoy presently missing.
Condition: Unknown
Due 6 August 1997
Resolved 6 August 1997
Navigation
Issued 6 August 1997
Resolved
provide ship's bell for examination, presently not on board the vessel.
Condition: Unknown
Due 6 August 1997
Resolved 6 August 1997