Inspection history · 69
12 December 2025
DAPI Audit
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8282613
10 December 2025
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8281646
13 January 2025
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8062937
11 December 2023
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7831428
11 December 2023
DAPI Audit
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7837921
19 January 2023
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7623678
21 June 2021
Initial Certification · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7303522
24 May 2021
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7205399
27 May 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6968071
10 August 2019
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6783569
30 May 2019
In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6699419
7 November 2018
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6576114
14 May 2018
Marine Casualty Follow Up
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6414476
12 May 2018
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6414468
17 February 2018
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6357501
30 September 2017
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6301208
10 December 2016
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6057017
25 March 2016
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5847880
2 June 2015
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 5143153
29 May 2015
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 5142404
24 April 2015
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5111607
30 May 2014
Industry Initiated Exam · Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4884001
30 October 2013
Administration
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4743895
22 August 2009
Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3583902
21 August 2009
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3577057
10 March 2009
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3434019
13 October 2008
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3346540
24 May 2008
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3227633
8 April 2008
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3189606
18 March 2008
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3182245
31 December 2006
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2858605
23 October 2006
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2815218
2 August 2005
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2448826
27 November 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2250367
21 September 2004
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2203961
19 July 2004
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2155960
27 April 2004
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2098313
30 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1986246
15 August 2003
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1906985
7 January 2003
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1741497
31 October 2002
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1716387
2 October 2002
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1686060
5 September 2002
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1673209
4 September 2002
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1676664
8 March 2002
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1598137
15 January 2002
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1480593
7 October 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 121029
6 October 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2406
20 September 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 77278
20 March 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 114669
5 March 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 9504
30 January 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 20381
13 November 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 409968
31 August 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 177453
9 August 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 144800
1 August 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 45157
10 June 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 141570
7 January 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 128620
16 July 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 47788
14 June 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 156713
19 May 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 125731
14 May 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 172768
10 May 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 39742
19 January 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 109332
21 July 1995
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 62242
17 June 1995
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 97059
17 April 1995
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 88674
22 September 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 30698
11 March 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 143882
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 10 December 2025
Resolved
The name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and stern of the vessel. Name and hailing port sign damaged by wind. Replace when new one arrives.
46CFR67.123
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2026
Resolved 23 December 2025
Resolution: Received objective evidence of satisfactory repairs.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 10 December 2025
Resolved
A towing vessel must carry adequate and up-to-date charts, maps, and nautical pubs for the intended voyage. Rose Point charts need to be updated. 46CFR140.705(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2025
Resolved 23 December 2025
Resolution: Received objective evidence of satisfactory repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 December 2025
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Dead end wires found in pilot house operating station cabinets. Repair/Replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2025
Resolved 30 December 2025
Resolution: Received objective evidence of satisfactory repairs.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 December 2025
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency light in upper quarters non-operational. Repair/Replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2025
Resolved 30 December 2025
Resolution: Received objective evidence of satisfactory repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 10 December 2025
Resolved
Towing vessel must carry a combination of day and night visual distress signals indicated in Table 141.370. Vessel had wrong type of flares. Replace with USCG approved flares.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2025
Resolved 23 December 2025
Resolution: Received objective evidence of satisfactory repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 10 December 2025
Resolved
Pressure vessels over 5 cubic feet in volume and over 15 pounds per square inch maximum allowable working pressure (MAWP) must be equipped with an indicating pressure gauge (in a readily visible location) and with one or more spring-loaded relief valves. Pressure gauge missing from forward pressure vessel in engine room.46 CFR 143.300 (a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2025
Resolved 23 December 2025
Resolution: Received objective evidence of satisfactory repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 December 2025
Resolved
Electrical equipment must be suitably installed to prevent them from coming loose through vibration or accidental contact. Battery charger not permanently secured to battery in E/R.46 CFR 143.400
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2025
Resolved 30 December 2025
Resolution: Received objective evidence of satisfactory repairs.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 10 December 2025
Resolved
All bilges and void spaces are kept free from accumulation of combustible materials and liquids insofar as practicable. Excessive oil leaking from gearbox into rosebox under the port shaft seal.46 CFR 142.220(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2025
Resolved 7 January 2026
Resolution: Received objective evidence of satisfactory repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 13 January 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Gauge for cooler system on main engine and gearbox is broken. Replace.
46CFR143.205
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2025
Resolved 13 March 2025
Resolution: Received objective evidence of satisfactory repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 January 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Hydraulic steering system has multiple leaks. Repair/replace as necessary to secure leaks.
46CFR143.205
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2025
Resolved 1 April 2025
Resolution: Satisfactory repairs made.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 13 January 2025
Resolved
A towing vessel must be maintained and operated so the watertight integrity and stability of the vessel are not compromised. Stern void is leaking. Repair.
46CFR140.605(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2025
Resolved 1 April 2025
Resolution: Satisfactory repairs made.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 December 2023
Resolved
Alcohol swabs were expired.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 12 December 2023
Resolved 12 December 2023
Resolution: Company replaced with new swabs
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 11 December 2023
Resolved
The vessel has been both in satisfactory service insofar as structural adequacy is concerned and does not cause the structure of the vessel to be questioned by either the OCMI, or TPO engaged to perform an audit or survey. Bow is flooded to water line. Demonstrate that flooding is intentional and not as a result of a leak.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2024
Resolved 5 January 2024
Resolution: Dewatered void, verified no water intrusion.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 December 2023
Resolved
more than 3 years elapsing since last test. Not able to test, no records available. Provide documentation of test.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2024
Resolved 5 January 2024
Resolution: Third party verified accuracy of PRV.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 19 January 2023
Resolved
Each towing vessel must have reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided:(6)Low hydraulic steering fluid levels, (7)Low fuel level, if fitted with a day tank. Vessel did not have low hydraulic steering fluid or day tank low fuel oil alarms
equipped. Provide indicated alarms to the satisfaction of an attending Marine Inspector.
46 CFR 143.230(a)(6)&(7)
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 2 February 2023
Resolved 26 January 2023
Resolution: Alarms provided
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 19 January 2023
Resolved
Alarms must be visible and audible at each operating station. Alarms were not visible or audible in the pilot house when testing the high bilge level alarm. Repair to the satisfaction of an attending Marine Inspector.
46 CFR 143.230(b)(1)
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 2 February 2023
Resolved 26 January 2023
Resolution: Alarm tested sat.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 19 January 2023
Resolved
All bilges and void spaces are kept free from accumulation of combustible and flammable materials insofar as practicable. Engine room bilge had excessive amounts of oil accumulated. Remove oil accumulation to the satisfaction of an attending Marine Inspector.
46 CFR 142.220(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 February 2023
Resolved 26 January 2023
Resolution: Bilges were pumped.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 19 January 2023
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Lower engine room emergency lighting was extinguished. Repair/Replace to the satisfaction of an attending Marine Inspector.
46 CFR 143.410(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 February 2023
Resolved 26 January 2023
Resolution: Light renewed. Tested Sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 January 2023
Resolved
Life-jackets must have the following attachments and fittings; (1)Each life-jacket must have a life-jacket light securely attached to the front shoulder area of the life-jacket,(2)Each life-jacket must have a whistle firmly secured by a cord to the life jacket. Life-jackets were missing required lights and whistles. Provide necessary attachments and fittings to the satisfaction of an attending Marine Inspector.
46 CFR 141.340(g)(1)&(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 February 2023
Resolved 26 January 2023
Resolution: Required attachments provided.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 1 December 2021
Resolved
A towing vessel must be maintained and operated so the watertight integrity and stability of the vessel are not compromised. Engine room has two hatches(scuttles)that don't operate correctly. Repair as needed. 46cfr140.605(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2021
Resolved 27 December 2021
Resolution: Repairs made and tested.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 1 December 2021
Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Measures must be in place to prevent flammable or combustible liquid piping leaks from coming into contact with these components. Lagging needs to be installed on exposed exhaust pipes from turbo chargers. 46cfr143.220(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2021
Resolved 27 December 2021
Resolution: Repairs made and verified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 1 December 2021
Resolved
The following systems must be equipped with gauges at the machinery location; Auxiliary generator engine lubricating oil pressure and auxiliary generator engine RPM. Tachometer gauges needs to be installed on the generators. 46cfr230(c)(3)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2021
Resolved 27 December 2021
Resolution: Gauges installed and tested.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 May 2021
Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the associated fleet that has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 90 days. If an inspection is not completed prior to this date, the action for this deficiency shall be changed to a 60 (Rectify deficiencies prior to movement) and the vessel may no long be permitted to operate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 August 2021
Resolved 19 January 2022
Resolution: COI issued
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 31 May 2019
Resolved
All bilges and void spaces are kept free from
accumulation of combustible and flammable materials and
liquids insofar as practicable. Identified 2-4 inches of
oil throughout the engine room bilge, beneath the port/
stbd engines & gens, fuel manifold, & the fwd portion of
the engine room, approx 18 ft wide by 25 ft in length,
posing an imminent hazard to the crew & environment, a
serious substandard condition not being pro-actively
managed by the Company, vessel owner, and/or operator. 46 CFR 142.220(a)
Condition: Invalid
Action required: 30 - Ship detained
Resolved 19 June 2019
Resolution: Engine room bilge cleaned, free and clear upon arrival.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 31 May 2019
Resolved
Each towing vessel must have a fire-detection system
installed to detect engine room fires, that is
installed, tested, and maintained in accordance with the
manufacturer’s design manual. Upon arrival, fire
detection panel displayed a fault, cause unknown to all
crew, crew unaware of how to properly test the system,
nor equipped with proper testing devices to conduct
these tests, and no records found attesting the fire
detection system being tested during monthly drills as
required, creating a serious substandard condition not
being pro-actively managed by the Company, vessel owner,
and/or operator. Provide technician report attesting to
the full operation of the fire detection system as
designed by the manufacturer. 46 CFR 142.330
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 19 June 2019
Resolution: Fire safety technician conducted repairs and testing of panel.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 31 May 2019
Resolved
Machinery and electrical systems must be designed and
maintained to provide for safe operation of the towing
vessel and safety of persons on board under normal and
emergency conditions. Starboard generator prime mover
has numerous lube oil leaks: at the L/O sensor, on the
bottom side of the pump running down the side of the
engine, and through the exhaust system resulting unsafe
oil soaked lagging and pooling on the flange, with oil
soaked pads surrounding the generator, all combined in
creating a serious substandard condition not being proactively managed by the Company, vessel owner, and/or operator. 46 CFR 143.205(a)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 19 June 2019
Resolution: L/O sensor replaced, leaks corrected.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 30 May 2019
Resolved
Vessel must be operated in accordance with applicable laws and regulations and in such manner as to afford protection against hazards to life, property, and the environment. Vessel allided with the Crescent City Connection Bridge causing damage to one of the five barges in tow. Provide a detail transit plan including all mitigating factors for safe transit to deliver the damage barge to a nearby repair facility and accommodate for CG Marine Inspector to come on board the Towing vessel. Vessel is to remain in place until the transit plan has been reviewed and approved by the Coast Guard. 46 CFR 140.205, 705c
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 2 June 2019
Resolution: Vessel submited a transit plan for the intended voyage.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 May 2019
Resolved
Machinery and electrical systems must be designed and
maintained to provide for safe operation of the towing
vessel and safety of persons on board under normal and
emergency conditions. Identified excessive shaft leakage
on port propulsion shaft with rigged means of
dewatering with pumps to maintain leakage, shaft leakage
water ingress is an aggravating factor in the oily water
found all within the engine room bilge, creating a
serious substandard condition not being pro-actively
managed by the Company, vessel owner, and/or operator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2019
Resolution: Packing replaced and tightened, significantly reduced shaft leakage.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 30 May 2019
Resolved
Machinery and electrical systems must be designed and
maintained to provide for safe operation of the towing
vessel and safety of persons on board under normal and
emergency conditions. As a result of the oil leaks on
both generator sets, the electrical windings have become
completely saturated in oil and need immediate cleaning.
Once trouble shooting and repairs have been affected,
clean generator set.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2019
Resolution: Provided photos of oil and debris removed from generator windings.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 May 2019
Resolved
Machinery and electrical systems must be designed and
maintained to provide for safe operation of the towing
vessel and safety of persons on board under normal and
emergency conditions. Observed oil soaked rag resting
over the vent for the stbd reduction gear accompanied by
almost the entire fwd section of the reduction gear
soaked in oil. Appears fwd main seal is faulty on
reduction gear. Trouble shoot to find the exact location
of leak and affect repairs to the prime mover.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2019
Resolution: Leaks corrected, oily rags removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 May 2019
Resolved
Propulsion machinery, including main engines, reduction
gears, and electrical equipment and systems must be
maintained to ensure proper operation. Overall condition
of main engines and generator prime movers is
substandard: numerous leaks , evidence of oil in
exhaust, and overall rough engine operation as witnessed
by Marine Inspector. Provide technicians report
attesting to the viability and performance of on board
machinery as designed by manufacturer.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2019
Resolution: Witnessed satisfactory operation, exhaust and lagging replaced.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 30 May 2019
Resolved
The officer in charge of a navigational watch must
conduct a navigation assessment for the intended route
and operations prior to getting underway. The navigation
assessment must incorporate the requirements of the
pilothouse resource management of 46 CFR 140.640, assess
operational risks, and anticipate and manage workload
demands. Navigational assessments are not being
completed as required, only saw evidence of voyage plans
which are a separate requirement.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2019
Resolution: Provided satisfactory nav assessment for review and approval.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 May 2019
Resolved
Safety orientations and other crew training must be
documented in the TVR, official logbook, or in
accordance with the TSMS applicable to the vessel. Found
no records of safety orientation being conducted for
crew members, persons in addition to crew and visitors,
and upon arrival, deckhands completely unaware of safety
orientation content to convey to on board guests.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2019
Resolution: Conducted satisfactory passenger safety orientation.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 30 May 2019
Resolved
The master of a towing vessel must ensure that drills
are conducted and instructions are given to ensure that
all crewmembers are capable of performing the duties
expected of them during emergencies. Found no record on
board for abandon ship and man over board drills
conducted by the current vessel crew.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2019
Resolution: Provided record of drills.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 30 May 2019
Resolved
Each towing vessel must have either a self-priming,
power-driven, fixed fire pump, a fire main, and hoses
and nozzles in accordance with paragraphs (a)-(d) of
this section. Water leakage found within the fixed fire
pump, and on the discharge side piping, flexible hosing
covered a piping pinhole, w/ shooting water out of the
flexible hosing sides, conduct permanent repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 June 2019
Resolution: Leaks corrected, witnessed satisfactory operation of fire pump.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 May 2019
Resolved
The frame or support of any size III, IV, or V semiportable
extinguisher fitted with wheels must be welded
or otherwise permanently attached to a steel bulkhead or
deck to prevent it from rolling under heavy sea
conditions. The on board B-V was unsecured on the second
deck, at risk for falling over/damage.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 June 2019
Resolution: Secured bracket added.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 May 2019
Resolved
If a dedicated storage cabinet is provided it must be
secured to the vessel so that it does not move and must
meet either UL 1275, FM Approvals Standard, or another
suitable steel container that provides an equivalent
level of safety. No approvals observed on the fire
locker, provide proof of ratings or equivalency, or
replace meeting 142.225(c)(1) or (c)(2).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 June 2019
Resolution: OSHA/NFPA 30 approved cabinet added with securing bolts to standpipe on deck.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 May 2019
Resolved
Each lifejacket must be marked in block capital letters
with the name of the vessel. Lifejackets on board not
marked with the vessel name. To be completed within 2
days.
Action required: 705 - Other - as specified
Resolved 19 June 2019
Resolution: All lifejackets marked with vessel name.