MAURY USCG vessel records
← All vessels

FMT 3030

Built
2000
Last inspected
26 May 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 26 May 2026
…with no type recorded9
Operational controls None recorded without a removal date
Years with a record 20 calendar years (2000–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Tonnage
1619 - Simplified, Gross Ton 1619 - Simplified, Net Ton
Maury page id
psix-11585
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 8

Inspection history · 36

26 May 2026 MTSA Verification · Internal Structural Exam · COI Inspection · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8380830
11 May 2023 Periodic Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7685128
24 March 2021 Administrative Inspection · Internal Structural Exam · Drydock Exam · MTSA Verification · Examination of Repairs · Cargo Tank Internal · COI Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7162087
25 October 2019 Administrative Inspection · Examination of Repairs · Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6841949
2 November 2018 Deficiency Check · MTSA Verification · Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6573494
13 September 2017 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6266030
22 September 2016 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6004085
15 July 2016 Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5941444
13 August 2015 Examination of Repairs · COI Inspection · MTSA Verification · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5207481
26 May 2015 Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5135665
30 April 2015 MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5113974
7 May 2014 MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4852337
17 October 2012 Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4466717
20 April 2012 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4289686
31 August 2011 Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4132221
21 August 2011 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4122607
12 August 2011 Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4118429
4 March 2010 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3691981
1 March 2010 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3688011
1 March 2010 Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3688317
14 January 2009 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3393857
8 September 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3353713
1 May 2008 MTSA Verification · Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3196686
30 May 2007 Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2946493
23 April 2007 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2913773
6 December 2005 Internal Structural Exam · Cargo Tank Internal · MTSA Verification · Hull Examination · COI Inspection
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2546893
3 December 2004 MTSA Verification · Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2252737
29 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978960
19 December 2003 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1967055
7 February 2003 Damage Survey
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1741495
4 February 2003 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1738882
17 May 2002 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1618042
12 March 2002 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1494754
19 February 2002 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1487486
20 December 2000 Examination of Repairs · Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1433768
5 December 2000 Initial Certification · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1445710

Deficiency record · 10

02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 25 October 2019 Resolved
On 22 OCT 2019: While in the Gates fleeting area located in Channelview, TX; owned and operated by FMT, CG Marine Inspectors identified insets IVO the #5 port wing tank that required repair. Vessel allowed to conduct a onetime discharge of Naptha then gas free and make permanent repairs in the Houston-Galveston AOR.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 October 2019
Resolved 29 October 2019
Resolution: CG Marine Inspectors witnessed repair of cargo tank top satisfactorily.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 November 2018 Resolved
Starboard side electrical connection box for cargo liquid high/overfill protection alarm is damaged. Replace alarm box on starboard stern.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2018
Resolved 5 November 2018
Resolution: Vessel installed new box.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 30 April 2015 Resolved
Paint and label vapor header line as per 46 CFR 39.20-1
Action required: 705 - Other - as specified
Due 30 May 2015
Resolved 26 May 2015
Resolution: Vapor header was correctlt stenciled.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 30 April 2015 Resolved
Tighten or replace #2 Starboard cargo tank remote operated valve packing.
Action required: 705 - Other - as specified
Due 30 May 2015
Resolved 26 May 2015
Resolution: Valve packing was repaired on the stbd #2 cargo tank remote operated valve.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 30 April 2015 Resolved
Replace starboard slop tank one meter (high level) indicating stick.
Action required: 705 - Other - as specified
Due 30 May 2015
Resolved 26 May 2015
Resolution: stbd slop tank meter stick was replaced.
Deck/Cargo › Cargo Stowage › General
Issued 1 May 2008 Resolved
Vessel has a cargo vapor leak located on the #3 starboard cargo tank sight glass. Vessel is allowed to discharge cargo and make permanent repairs prior to further cargo operations.
Action required: 705 - Other - as specified
Resolved 14 January 2009
Resolution: Vessel operator made satifactory repairs and replaced entire sight glass.
Construction/Loadline › Hull
Issued 7 February 2003 Resolved
Prior to loading any regulated cargo, gas free voids and verify safe for entry to conduct an internal examination to the satisfaction of the attending marine inspector. LEGACY COMPONENT DESC: Bottom Plating
Due 8 February 2003
Resolved 8 February 2003
Resolution: Verified and cleared item listed above.
Stability › Watertight Integrity
Issued 7 February 2003 Resolved
Remove all water from No. 3, 4, & 5 starboard and No. 4 wing voids and demonstrate watertight integrity of voids to the satisfaction of the attending marine inspector.
Due 8 February 2003
Resolved 8 February 2003
Resolution: All water was removed from the spaces indicated above and proven watertight.
Pollution Prevention/Response › Prevention Equipment
Issued 19 February 2002 Resolved
Prove proper operation of liquid overfill alarms as per 33 CFR 155.480, prior to using the Vapor Control System. LEGACY COMPONENT DESC: Overfill Devices
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 April 2002
Resolved 12 March 2002
Resolution: WITNESSED SATISFACTORY TEST OF OVERFILL ALARMS.
Construction/Loadline
Issued 5 December 2000 Resolved
Proceed to dry-dock and make permanent repairs to launch damage in the #1 STBD wing void/double bottom in the area of the bilge knuckle. Vessel is not to carry cargo until repairs are complete.
Condition: Unknown
Due 5 December 2000
Resolved 5 December 2000

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.