Records from 2001 to 2024. Most recent: inspection, 20 November 2024.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS · ASHLAND CITY, TN, UNITED STATES · built 2000
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 May 2026 · expires 31 May 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Regulatory (Subpart C or D), Gross Ton
1619 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 37
20 November 2024
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8037658
26 August 2024
Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7989682
3 July 2024
Administrative Inspection · Deficiency Check · Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7948298
8 April 2021
COI Inspection · Internal Structural Exam · Cargo Tank Internal · MTSA Verification · Drydock Exam · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7157205
24 September 2020
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7075695
3 July 2020
Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6994325
17 July 2019
MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6759794
13 June 2018
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6443497
13 July 2017
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6208142
7 April 2016
COI Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5847455
18 March 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5836230
17 March 2016
Administrative Inspection · In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5837501
4 May 2015
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5113883
31 March 2014
Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4827727
22 May 2012
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4319067
22 December 2010
Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3925613
29 April 2010
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3729893
21 April 2010
Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3721250
18 March 2010
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3698280
23 December 2008
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3389094
23 December 2008
Damage Survey
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3390115
23 December 2008
Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3390143
13 March 2008
MTSA Verification · Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3163711
30 April 2007
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2919331
20 March 2007
Re-Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2891525
10 May 2006
Damage Survey
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2645625
9 May 2006
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2651866
19 January 2006
Internal Structural Exam · COI Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2569407
16 March 2005
Periodic Inspection · MTSA Verification
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2311995
26 March 2004
Periodic Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2030280
29 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978962
30 January 2003
Periodic Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1737469
11 December 2002
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1717868
4 June 2002
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1626589
12 February 2002
Periodic Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1486052
22 January 2001
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 825068
2 January 2001
Initial Construction-Excluding Oversight · Initial Certification · Hull Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1376405
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 11 July 2024
Resolved
ach cargo tank of a tank barge must have one of the following liquid overfill protection arrangements:
(2) An intrinsically safe overfill control system that—(i) Is independent of the cargo-gauging device required by 46 CFR 39.2003(a).
Marine Inspectors were unable to test overfill control system alarms due to inoperable alarm box. Repair or replace box and provide proof of proper operation to the satisfaction of the Marine Inspector.
46 CFR 39.2009(a)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 July 2024
Resolution: Recieved video from barge rep of satisfactory test of overfill alarms.
02 - Structural Conditions › N/A - No Subsystem › Enhanced survey programme (ESP)
Issued 11 July 2024
Resolved
Scantlings, material, and workmanship, subdivision of cargo spaces, fitting of cofferdams, and testing of tanks shall be at least equivalent to the requirements of the American Bureau of Shipping or other recognized c
classification society.
Marine Inspector identified multiple areas of excessive pitting greater than 25% wastage around entire raised tank trunk. Vessel must gauge suspected areas and provide repair proposal to the satisfaction of the OCMI.
46 CFR 32.60-1(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2024
Resolved 26 November 2024
Resolution: Deficiecny was rectified by SEC NOLA. MISLE Activity 7989682 on 26 AUG 2024.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 3 July 2020
Resolved
Any tank vessel which is equipped with an internal combustion engine driven cargo pump on the weather deck shall be provided with a minimum of one remote manual shutdown station, conspicuously marked, and located at the midpoint of such vessel, or 100 feet from the engine, whichever is the more practical. The remote quick acting manual shutdown shall be installed on the engine so as to provide a quick and effective means of stopping the engine (such as by cutting off the intake air).
Vessel Representative was unable to start the prime mover and therefore could not satisfactorily demonstrate an effective means to stop the engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2020
Resolution: Received satisfactory evidence of permanent repairs being enacted.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 18 March 2016
Resolved
Vessel failed to be cleaned and gas free prior to the expiration of their COI. The vessel did discharge prior to exipration of COI, so only residues remain.
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 March 2016
Resolved 13 July 2017
Operations/Management › Cargo Transfer/Lightering › Use of Vapor Control System
Issued 31 March 2014
Resolved
PV valve not installed porperly. Make repairs prior to cargo ops.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2014
Resolution: Valve repaired.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 18 March 2010
Resolved
Due to wastage the port stern winch wheel must be replaced/repaired.
Action required: 705 - Other - as specified
Due 3 May 2010
Resolved 29 April 2010
Resolution: Winch was removed from vessel, hand wheel was heated and removed. New hand wheel installed.
Construction/Loadline
Issued 2 January 2001
Resolved
Make permanent repairs to bilge knuckle set ins and damage to frames 6 and 12 in the STBD #1 & #2 wing voids before vessel conducts cargo operations. All repairs to be made to the satisfaction of the cognizant CG-OCMI.
Condition: Unknown
Due 2 January 2001
Resolved 2 January 2001