Records from 2002 to 2022. Most recent: inspection, 29 June 2022.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS, INC · MADISONVILLE, LA, UNITED STATES · built 2002
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 20 June 2026 · expires 31 July 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 35
29 June 2022
Internal Structural Exam · Administrative Inspection · COI Inspection · Examination of Repairs · Drydock Exam · Cargo Tank Internal
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7490877
16 December 2020
Periodic Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7112675
3 January 2020
Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6887244
13 December 2018
Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6597173
26 November 2018
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6587065
3 October 2017
Internal Structural Exam · COI Inspection · Examination of Repairs · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6280106
21 December 2016
Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6060621
23 August 2016
Annual Inspection · MTSA Verification · Examination of Repairs · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5981931
7 July 2015
Periodic Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5175470
5 January 2015
Examination of Repairs · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5048042
29 December 2014
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5045109
24 December 2014
Permit to Proceed · Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5043878
24 December 2014
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5048363
28 August 2014
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4967675
23 July 2013
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4662502
18 August 2012
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4415320
16 May 2012
Internal Structural Exam · Cargo Tank Internal · MTSA Verification · Examination of Repairs · COI Inspection · Administrative Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4313047
25 August 2011
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4124781
20 August 2010
Periodic Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3827505
12 April 2010
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3715255
12 April 2010
Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3715559
6 August 2009
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3556470
10 July 2008
Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3260439
12 June 2007
MTSA Verification · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2955590
30 April 2007
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2919331
29 August 2006
Re-Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2763139
13 July 2005
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2425596
30 June 2005
Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2409004
30 November 2004
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2250562
6 July 2004
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2123630
29 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1979060
16 September 2003
Deficiency Check
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 1906151
9 September 2003
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1900007
8 July 2002
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1650927
4 June 2002
Hull Examination · Cargo Tank Internal · Initial Construction-Excluding Oversight · Initial Certification · Internal Structural Exam
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1626111
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 7 July 2015
Resolved
8 inch cargo transfer hose properly blanked at both ends and marked with (barge company issued) serial number FMT 524 on board vessel (but not attached to cargo transfer system) had no record of testing. Records required to be available as per 33 CFR 155.820. Hose requires proper test records prior to being used or to be removed from vessel to prevent its use.
Action required: 705 - Other - as specified
Due 7 July 2015
Resolved 7 July 2015
Resolution: Hose immediately removed from vessel.
Construction/Loadline › Hull › Bottom Plating
Issued 24 December 2014
Resolved
Bow rake has collision damage. Make permanent repairs.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 January 2015
Resolved 6 January 2015
Resolution: Repairs completed and conducted air test. Vessel fit for service.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 29 August 2006
Resolved
The emergency air shut down was tied open with a piece of lanyard so the engine can operate.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2006
Resolved 31 August 2006
Resolution: installed new emergency air shut down valve
Pollution Prevention/Response › Prevention Equipment
Issued 9 September 2003
Resolved
Prove proper operation of high level shutoff alarms LEGACY COMPONENT DESC: Overfill Devices
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 September 2003
Resolved 16 September 2003
Resolution: Found correct.
Engineering › Diesel Engine (auxiliary)
Issued 9 September 2003
Resolved
Prove proper operation of prime mover RPM gauge.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 September 2003
Resolved 16 September 2003
Resolution: Found correct.