Records from 2013 to 2025. Most recent: inspection, 13 May 2025.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFBOAT LLC · JEFFERSONVILLE, IN, UNITED STATES · built 2013
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portNASHVILLE, TN
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 23 March 2026 · expires 30 April 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 18
13 May 2025
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8135207
1 September 2022
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7549157
2 August 2022
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7522911
20 May 2022
Drydock Exam · Internal Structural Exam · COI Inspection · MTSA Verification · Examination of Repairs · Cargo Tank Internal
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7439468
30 March 2021
Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7165669
18 May 2020
MTSA Verification · Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6955326
27 February 2020
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6917153
24 October 2019
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6841174
18 March 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6644316
22 May 2018
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6420519
22 January 2018
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6354943
7 April 2017
Internal Structural Exam · COI Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6117795
3 October 2016
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6013014
8 September 2015
MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5736529
13 August 2014
Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4922028
31 July 2014
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4947123
5 November 2013
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4747924
18 June 2013
Internal Structural Exam · MTSA Verification · Cargo Tank Internal · Deadweight Survey · Hull Examination · Initial Certification · Administrative Inspection · Initial Construction-Excluding Oversight
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4678714
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 3 October 2016
Resolved
Cargo pump relief valves shall be tested at least once each year to determine they function satisfactorily at the pressure at which they are set to open. Vessel could not present any documentation to the attending marine inspector attesting to the completion of the test. Test shall be conducted prior to the vessel conducting cargo discharging operations. 46 CFR 35.35-70(b)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 October 2016
Resolved 6 October 2016
Resolution: Vessel provided tech report from Industrial [name withheld] attesting to the satisfactorily testing of the cargo pump relief valves.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 3 October 2016
Resolved
Cargo pump pressure gauges shall be tested at least once a year for accuracy. Vessel could not provide documentation to the attending marine inspector attesting to the satisfactory testing of the pressure gauge. Testing shall occur prior to the vessel conducting cargo discharge operations. 46 CFR 35.35-70(c)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 October 2016
Resolved 6 October 2016
Resolution: Vessel provided a tech report from Industrial [name withheld] attesting to the satisfactory testing of the cargo pump pressure gauge.
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 8 September 2015
Resolved
COFR and VRP indicate owner when it should indicate operator as per lease agreement with owner
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 September 2015
Resolved 16 September 2015
Resolution: COFR and VRP updated with operator name
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 8 September 2015
Resolved
The starboard alarm electrical connection inner box has broken free from its external casing and was hanging by its wires.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 September 2015
Resolved 28 September 2015
Resolution: Alarm box repaired.