MAURY USCG vessel records
← All vessels

CC PORTLAND

CC PORTLAND is a 2018 towing vessel. The Coast Guard has recorded 12 inspections since 2018, most recently in February 2025, along with 11 deficiencies and 1 casualty investigation in 2022.

Records from 2018 to 2025. Most recent: inspection, 15 February 2025.

Built
2018
Last inspected
15 February 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the tow units, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 15 February 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2018–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9824112
WDK3262
1494614
Flag
UNITED STATES
Maury page id
psix-1494614

Documentation record

Registered dimensions (L × B × D)102.5 ft
Registered tonnagegross 293 / net 200
ITC dimensions (L × B × D)96.4 ft × 42.7 ft × 19.7 ft
ITC tonnagegross 514 / net 154
BuilderTAMPASHIP LLC · TAMPA · built 2018
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portGALLIANO, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 22 July 2026 · expires 31 August 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it514 - Convention (Subpart B), Gross Ton
293 - Regulatory (Subpart C or D), Gross Ton
154 - Convention (Subpart B), Net Ton
200 - Regulatory (Subpart C or D), Net Ton
379 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

12 inspections, each with its date, unit and type; 11 deficiencies with the resolution recorded against each; 4 vessels inspected with it, by name and date; 1 casualty investigation, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CC GREGORY Towing Vessel · MISLE 1494609 · 7 August 2022 · activity 7528511CC LA QUINTA Towing Vessel · MISLE 1494612 · 7 August 2022 · activity 7528511CC ARANSAS Towing Vessel · MISLE 1494613 · 7 August 2022 · activity 7528511LNG FUKUROKUJU Tank Ship · MISLE 1639713 · 7 August 2022 · activity 7528511

Inspection history · 12

15 February 2025 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8086478
29 August 2024 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7991783
24 July 2024 Administrative Inspection · COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7965921
19 December 2023 Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7840730
15 August 2023 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7769166
22 August 2022 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7540359
11 August 2022 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7531928
7 August 2022 Damage Survey · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7527423
7 August 2022 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7528511
27 July 2022 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7517934
12 April 2022 Initial Certification · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7429698
19 December 2018 Plan Review (Other than "T")
Administrative · USCG Heartland District (dp) · USCG Heartland District (CGD-H) · Activity 6600110

Deficiency record · 11

01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 August 2024 Resolved
Vessel is inspected under the TSMS option and the requirement of 46 CFR § 138.115 is satisfied. Provide objective evidence of TSMS implementation for six months from the date of the COI. Failure to complete this requirement will result in removal of the TSMS endorsement from the vessel’s COI, suspension of vessel operations, or COI revocation, as determined by the OCMI.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 February 2025
Resolved 12 February 2025
Resolution: Vessel has provided objective evidenc of TSMS implementation for the past six months. As determined by the OCMI.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 15 August 2024 Resolved
Each towing vessel must be fitted with a general alarm that: Has installed, in the engine room and any other area where background noise makes a general alarm hard to hear, a supplemental flashing red light. Flashing red light was not operational. Repair or replace to the satisfaction of the TPO surveyor.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2024
Resolved 26 August 2024
Resolution: Received ABS Survey report.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 15 August 2024 Resolved
Prior to getting underway for the first time on a particular towing vessel, each crewmember must receive a safety orientation on: The location, operation, and use of lifesaving equipment. Fire Control Plans in tubes on exterior of vessel are unreadable and damaged. Repair or replace to the satisfaction of the TPO surveyor.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2024
Resolved 26 August 2024
Resolution: Received ABS Survey Report.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 30 August 2023 Resolved
Survival craft must be stowed in accordance with the requirements of § 199.130 of this chapter, as far as is practicable on existing towing vessels. Each liferaft or group of liferafts must be arranged for float-free launching. The arrangement must ensure that the liferaft or liferafts, when released and inflated, are not dragged under by the sinking vessel. The vessel's painter was attached to the vessel in a way that would not allow it to float free. Vessel was shown the proper way to attach float free system. Ensure all liferafts on the vessel are arranged to allow float free to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 September 2023
Resolution: Vessel attached the float free system properly
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 30 August 2023 Resolved
An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard or rail. This is not meant to restrict access to towing equipment such as winches, drums, towing gear or steering compartment equipment necessary for the operation of the vessel. Vessel's starboard z-drive guard is removed. Securely fasten machinery guard in accordance to manufacturer's specifications.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 September 2023
Resolution: Vessel installed machinery guard.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 August 2023 Resolved
Electrical conductors passing though watertight bulkheads must be installed so that the bulkhead remains watertight. Wires passing through the bulkhead in the engine room to the z-drive room were not water tight. Ensure wire penetrations and wedges are installed to the accordance to manufacturers specifications and to the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 October 2023
Resolution: Vessel had a tech install roxtec.
09 - Working and Living Conditions › 091 - Living Conditions › Ventilation (Accommodation)
Issued 30 August 2023 Resolved
Each vessel must be designed and constructed to minimize fire hazards insofar as reasonable and practicable. Piping in the laundry room going through the ceiling to the accommodation space was not in accordance to the vessels fire control plan. Ensure penetration is properly insulated to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 October 2023
Resolution: Vessel had technication install roxtec
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 August 2022 Resolved
A towing vessel that is certificated for limited coastwise, coastwise, oceans, or beyond 3 nautical miles from shore on the Great Lakes whose contract for construction was executed on or after August 27, 2003, except for those specified in paragraph (a)(3) of this section, must be equipped with both: an approved 160-B semi-portable fire-extinguishing system to protect the engine room; and a fixed fire-extinguishing system installed to protect the engine room. Vessel does not have the required 160-B semi-portable fire-extinguishing system on board. 46 CFR 142.315(b)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 September 2022
Resolved 24 October 2022
Resolution: Vessel obtained a 160-B Semi portable fire extinguisher on board.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 7 August 2022 Resolved
The owner and managing operator must ensure that the towing vessel is in compliance with this subchapter and other applicable laws and regulations at all times. Vessel's #2 Stbd fuel tank is leaking after grounding. Assess hull for additional damage and repair to the satisfaction of the USCG Marine Inspector. 46 CFR 137.120 (a)
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 24 August 2022
Resolved 24 October 2022
Resolution: Observed satisfatory repairs of the fuel tank.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 August 2022 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Vessel's stbd z-drive is leaking oil after grouding. Port z-drive is fouled with tow line. Assess both z-drives for damage and repair to the satisfaction of the USCG Marine Inspector. 46 CFR 143.205 (a)
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 24 August 2022
Resolved 24 October 2022
Resolution: Replaced Z-drive with new.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 July 2022 Resolved
A towing vessel that is certificated for limited coastwise, coastwise, oceans or beyond 3 NM from shore on the great lakes whose contract for construction was executed on or after August 27, 2003 except for those specified in paragraph (a)(3) of this section, must be equipped with both: an approved 160B semi-portable and a fixed fire extinguishing system to protect the engine room. Vessel does not have the required 160B semi-portable fire extinguishing system on board.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 October 2022
Resolution: Obtained 160-B Semiportable Fire Extinguisher.

Casualty record · 1

7 August 2022Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 7528511
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.