Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
83 - Simplified, Gross Ton
66 - Simplified, Net Ton
Maury page id
psix-1547555
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. Only barges and towing
vessels are in this archive, so any other vessel type in the same activity does not
appear here: these lists are a floor, not a complete manifest.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 April 2023Resolved
Machinery must be maintained to provide for safe operation of towing vessel under normal operating conditions. The vessel received a high temperature alarm on the starboard engine. The crew shut the engine down to troubleshoot the alarm.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 April 2023
Resolution: Attended vessel and verified repairs made to the starboard main engine cooling system.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 23 March 2023Resolved
Emergency lighting must... be automatic, battery operated with a duration of no less than 2 hours; or Non-electric, phosphorescent adhesive lighting strips that are installed along escape routs and sufficiently visible to enable egress with no power.
STBD engine room emergency lighting back up battery failed. Replace the light battery to the satisfaction of the OCMI.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 March 2023
Resolved 23 March 2023
Resolution: The lighting fixture was replaced on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 March 2023Resolved
Lifejackets must have the following attachments and fittings: (1) Each lifejacket must have a light... (2) Each lifejacket must have a whistle.
One lifejacket onboard was missing a light and whistle.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 March 2023
Resolved 23 March 2023
Resolution: The missing light and whistle were replaced.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 23 March 2023Resolved
The master of a towing vessel must ensure that drills are conducted and instructions are given to ensure that all crewmembers are capable of performing the duties expected of them during emergencies.
The crew failed to satisfactorily perform fire and MOB drills in the presence of Marine Inspectors.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2023
Resolved 19 April 2023
Resolution: Witnessed underway man overboard drill on the starboard side and fire drill in the engine room. Communication was improved since last drill and crew knowledgeable in shipboard procedures, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 23 March 2023Resolved
Each towing vessel must perform the applicable tests in table 143.245(b)... All other essential systems at least once every three months.
The vessel had not tested their steering low hydraulic fluid alarms.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 March 2023
Resolved 23 March 2023
Resolution: The shoreside engineers tested the hydraulic fluid alarms in the presence of the CG.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 March 2023Resolved
A fixed fire pump must be capable of delivering water simultaneously from the two highest hydrants, or from both branches of the fitting if the highest hydrant is a Siamese fitting at a pitot-tube pressure of at least 50 PSI and a flow rate of at least 80 gpm.
The fire pump only pushed out 20 PSI of water with one fire station open. Repair to the satisfaction of the OCMI.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 March 2023
Resolved 23 March 2023
Resolution: The companies shore side engineers flushed debris out of the fire pump sea chest and then it was able to make the correct pressures.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 27 April 2022Resolved
The owner, managing operator, or master of a towing vessel must ensure that the vessel's lifesaving and fire suppression and detection reequipment complies with the applicable requirements of parts 141 and 142 of this subchapter and is in good working order, during a test of the fire main, there was not adequate water pressure in order to suppress a fire.
Action required: 10 - Deficiency Rectified
Due 27 April 2022
Resolved 27 April 2022
Resolution: There was a clog at the first valve beyond the sea chest, within the engine room. Crew was able to correct this on the spot.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 April 2021Resolved
High level bilge alarm was not working, a switch had to be replaced within the electrical alarm system.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 April 2021
Resolved 14 April 2021
Resolution: Technician responded and replaced a switch that had gone bad in the system.