MAURY USCG vessel records
← All vessels

ROBERT T

Built
1978
Last inspected
12 May 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 12 May 2026
…with no type recorded7
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 14 calendar years (1999–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

7738981
WDC4303
155860
Flag
UNITED STATES
Maury page id
psix-155860

Documentation record

Registered dimensions (L × B × D)72.5 ft × 24.2 ft × 10.4 ft
Registered tonnagegross 131 / net 89
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHOUMA SHIPBUILDING, INC. · HOUMA, LA, UNITED STATES · built 1978
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCHESAPEAKE, VA
Endorsements, as the file codes themcw_un, rec, reg
DocumentationValid · issued 3 August 2026 · expires 31 August 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it131 - Regulatory (Subpart C or D), Gross Ton
89 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 25 inspections, each with its date, unit and type; 35 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; 5 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 5

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

KS 6025 Freight Barge · MISLE 1647851 · 18 May 2024 · activity 7921545ATLANTIC Industrial Vessel · MISLE 48792 · 2 May 2017 · activity 6198194OCEAN TOWER Towing Vessel · MISLE 156305 · 2 May 2017 · activity 6198194B.R.-8 Freight Barge · MISLE 438534 · 2 May 2017 · activity 61981946002 Industrial Vessel · MISLE 668588 · 2 May 2017 · activity 6198194

Inspection history · 25

12 May 2026 Examination of Repairs · Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8370765
6 May 2026 Suspicious Activity - Cybersecurity · Vessel Attendance
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8367787
22 January 2026 COI Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8294904
20 January 2026 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8298910
1 October 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8244999
5 September 2024 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7996823
18 May 2024 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7921545
7 September 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7778505
11 July 2023 Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7739825
29 September 2022 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7567408
16 March 2022 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7412681
26 January 2022 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7386207
12 January 2022 Administrative Inspection · Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7380128
2 June 2020 Initial Certification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6968795
27 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6524332
13 June 2017 Deficiency Check · Industry Initiated Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6201032
2 May 2017 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6198194
22 August 2016 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6020230
6 June 2013 Industry Initiated Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4616137
24 January 2012 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4219050
20 December 2011 Industry Initiated Exam · MTSA/ISPS Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4209692
12 February 2003 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1744113
22 June 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 755794
21 June 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 211266
18 June 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 69424

Deficiency record · 35

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 January 2026 No resolution recorded
Each towing vessel must perform the applicable tests in Table 143.245(b) of this section: Pressure vessel relief valves: Twice every 5 years, with no more than 3 years elapsing since last test. MI observed 02 air receiver pressure relief valves that have not been tested in over 3 years. 46 CFR 143.245 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2026 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 January 2026 Resolved
Each wire and cable run must be installed in a manner to prevent contact with personnel, mechanical hazards, and leaking fluids. MI observed exposed wires and broken cover on junction box in the crawl space below wheelhouse. 46 CFR 143.575 (a)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2026
Resolved 23 March 2026
Resolution: rectified
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 22 January 2026 Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. These devices must be suitable for the expected route. MI observed inoperable interior closing device on forepeak. 46 CFR 144.320 (a)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2026
Resolved 23 March 2026
Resolution: Replaced Hatch.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 20 January 2026 Resolved
All owners or managing operators of more than one existing towing vessel required to have a COI by this subchapter must ensure that each existing towing vessel under their ownership or control is issued a valid COI according to the following schedule. Vessel is outside of their COI renewal inspection window therefore making their COI expired. 46 CFR 136.202(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 January 2026
Resolved 22 January 2026
Resolution: Completed COI inspection
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 12 September 2024 Resolved
Provide satisfactory immersion suits. Incorrect size immersion suit provided.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2024
Resolved 18 September 2024
Resolution: Correct size immersion suit was provided for each crewmember.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 September 2024 Resolved
Provide satisfactory fire-detection system maintenance record. No records on board for system maintenance.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2024
Resolved 18 September 2024
Resolution: Fire detection servicing record was provided from April 2024.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 September 2024 Resolved
Flammable and combustible products must not be stored in machinery space. Engine room contained flammable liquid and acetylene bottle.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2024
Resolved 18 September 2024
Resolution: Flammable liquids and acetylene was removed from the engine room.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 September 2024 Resolved
All life saving equipment is properly maintained. Missing retro on port and starboard lifebuoys.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2024
Resolved 18 September 2024
Resolution: Retro was replaced on the life rings.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 12 September 2024 Resolved
Must be equipped with industrial first aid kit. Contents of first aid kit were expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2024
Resolved 18 September 2024
Resolution: Expired items were replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Bulwarks and freeing ports
Issued 12 September 2024 Resolved
Deck house shall be weather tight. Multiple cable runs and holes in bulwark were not sealed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2024
Resolved 18 September 2024
Resolution: All bulkhead penetrations were sealed.
09 - Working and Living Conditions › 092 - Working Conditions › Danger areas
Issued 12 September 2024 Resolved
Mitigate safety hazards. Portable heater found in head.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2024
Resolved 18 September 2024
Resolution: Heater was removed.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 12 September 2024 Resolved
Provide clear field of vision. Starboard bridge window is cracked.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2024
Resolved 18 September 2024
Resolution: Window was replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 12 September 2024 Resolved
Each watertight door must be marked on both sides. Multiple watertight doors were missing required marks.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2024
Resolved 18 September 2024
Resolution: All WTD were properly marked.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 September 2024 Resolved
Fuel shutoff valve must be marked in clearly legible letters at least 1 inch high, indicating the purpose of the valve and the way to operate it. Valves not clearly labeled.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2024
Resolved 18 September 2024
Resolution: Fuel shutoff pull handles were color coded, green for the stbd engine and red for the port.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 September 2024 Resolved
Electrical connections must be suitably installed. Freezer was powered by an extension cord.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2024
Resolved 18 September 2024
Resolution: A new receptacle was installed near the freezer and the freezer was properly plugged into it.
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 12 September 2024 Resolved
Identify and mitigate health and safety hazards. Fridge, stove, and oven were not secured to mitigate safety hazards to crew.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2024
Resolved 18 September 2024
Resolution: Fridge and stove were attached to the bulkhead and latches were installed. A rack was installed on the stove to keep pots and pans from sliding off.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 12 September 2024 Resolved
Provide satisfactory communication equipment. 2 VHF radios not programed with MMSI number.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2024
Resolved 18 September 2024
Resolution: MMSI number was programmed into each radio.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 September 2024 Resolved
Alcohol testing devices need to be carried on board. Alcohol testing devices are expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2024
Resolved 18 September 2024
Resolution: New alcohol test strips were provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 September 2024 Resolved
Provide satisfactory drug and alcohol program. provide proof of crew member enrollment and EAP documentation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2024
Resolved 18 September 2024
Resolution: DAPI documents were provided.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 5 September 2024 Resolved
Each towing vessel must have a fire-detection system installed to detect engine room fires. The fire detection panel has no operating lights, the test switch does not do anything, and there are no indications the system is operating properly. Loose wire was found. Repaired and tested, all sat.
Action required: 10 - Deficiency Rectified
Resolved 18 September 2024
Resolution: Loose wire was found. Repaired and tested, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 7 September 2023 Resolved
Except as provided in paragraph (a)(4) of this section, each towing vessel operating north of lat. 32 degrees North or south of latitude 32 degrees must carry the number of immersion suits as prescribed in this paragraph (a): Each towing vessel operating in those regions must carry at least one appropriate-size immersion suit. In addition to the immersion suits required under paragraph (1)(a) of this section, each watch station, work station, and industrial work site must have enough immersion suits to equal the number of persons normally on watch in, or assigned to the station or site at one time. Vessel did not have enough immersion suits on board IAW COI. 46CFR141.350(a)(1)(2)
Action required: 705 - Other - as specified
Due 14 September 2023
Resolved 8 September 2023
Resolution: Vessel rep sent receipt along with pictures of 02 CG approved immersion suits.
14 - Pollution Prevention › N/A - No Subsystem › VGP: General
Issued 7 September 2023 Resolved
When operating a vessel on a body of water where the discharge of treated or untreated sewage is prohibited by the EPA, the operator must secure each Type I or Type II device in a manner which prevents discharge of treated or untreated sewage. Acceptable methods of securing the device include (1) Closing the seacock and removing the handle,(2) padlocking the seacock in the closed position, (3) Using a non-releasable wire-tie to hold the seacock in the closed position; (4) Locking the door to the space enclosing the toilets with a padlock or door handle key lock. MI observed the MSD discharge valve open and unsecured while moored to pier. MSD discharge valve is required to be secured immediately but not more than 7 days. 33CFR159.7(b)
Action required: 705 - Other - as specified
Due 14 September 2023
Resolved 13 September 2023
Resolution: Device was locked.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 7 September 2023 Resolved
Each towing vessel operating in oceans and coastwise service must have a line throwing appliance approved under approval series 160.040. Vessel has (4) expired line throwing appliances. 46CFR141.385
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2023
Resolved 13 September 2023
Resolution: New line throwing devices were purchased.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 7 September 2023 Resolved
An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard or rail. Port and Starboard engine has exposed rotating machinery. 46CFR144.820
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2023
Resolved 13 September 2023
Resolution: Guards were replaced on both engines.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 September 2023 Resolved
All hand-portable fire extinguishers, semi-portable fire-extinguishing systems, and fixed fire-extinguishing systems required by this part must be approved by the Commandant (CG–ENG). MI observed a portable fire extinguisher in Fiddley not mounted with approved bracket and placed in front of emergency escape door. In addition, MI observed portable fire extinguisher in forward compartment laying on its side on deck and not secured. 46CFR142.215(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2023
Resolved 13 September 2023
Resolution: Portable fire extinguishers were mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 September 2023 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. MI observed exposed wiring in ceiling of galley and main deck head. 46CFR143.400(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2023
Resolved 13 September 2023
Resolution: Wires were contained.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 7 September 2023 Resolved
Each exhaust pipe from an internal combustion engine which is within reach of personnel must be insulated or otherwise guarded to prevent burns. Main exhaust pipe was missing large patch of lagging in upper area of pipe within fiddley room. 46CFR144.830
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2023
Resolved 13 September 2023
Resolution: Lagging was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 September 2023 Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid into the machinery space. MI observed fuel leak and lube oil leak in engine room. 46CFR143.220(a)
Action required: 10 - Deficiency Rectified
Resolved 7 September 2023
Resolution: Vessel crew corrected on the spot.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 January 2022 Resolved
Each towing vessel must be equipped with navagation lights, shapes, and sound signals IAW COLREGS or 33CFR84 as appropriate. Vessels mast and towing nav lights were damaged during accident. Vessel is restricted to daylight and high visibility operations only. 46CFR140.720
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 March 2022
Resolution: Vessel has nav lights repaired.
10 - Safety of Navigation › N/A - No Subsystem › Navigation bridge visibility
Issued 12 January 2022 Resolved
Windows and other openings at the operating station must be of sufficient size and properly located to provide a clear field of vision for safe operation in any condition. Vessel had 02 windows on bridge, and 01 stbd side main deck porthole break. Repair and replace to the satisfaction of attending MI's. 46CFR144.905(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 March 2022
Resolution: Vessel had windows repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 12 January 2022 Resolved
Towing vessels on a coastwise route are req'd to have liferaft if operating greater than 3nm from shore. Vessel is restricted to 3nm from shore until liferaft is repaired/replaced. 46CFR141.305(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 March 2022
Resolution: Vessel bought and installed new liferaft.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 January 2022 Resolved
A towing vessel operating greater than 3nm from shore must be equipped with an approved 160-B semi-portable fire-extinguishing system or a fixed fire system to protect engine room. Semi-portable was damaged during accident. Repair or replace to the satisfaction of attending MI's. 46CFR142.315(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 March 2022
Resolution: Vessel replaced B-160 semi-portable fire extinguisher.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 January 2022 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. A leak was found on the stbd exhaust. Repair to the satiisfaction of attending MI's. 46CFR143.205(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 March 2022
Resolution: Exhaust was repaired.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 12 January 2022 Resolved
Each towing vessel must be capable of preventing all oil spills from reaching the water during transfers by pre-deploying sorbent material on the deck around vents and fills. Vessels spilll kit was damaged during accident. Replace to the satisfaction of attending MI's 46CFR140.655(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 March 2022
Resolution: Vessel replaced spill kit.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 27 August 2018 Resolved
Vessel broadcasting no IMO # and an invalid CALL SIGN
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 November 2018
Resolved 23 October 2018
Resolution: Verified CG NAVCEN VIVS, no AIS deficiencies pending per website.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.