ATLANTIC

ATLANTIC is a 1976 industrial vessel. The Coast Guard has recorded 81 inspections since 1984, most recently in May 2025, along with 120 deficiencies — 4 with no resolution recorded — and 4 casualty investigations between 2017 and 2022.

Records from 1984 to 2025. Most recent: inspection, 8 May 2025.

Built
1976
Last inspected
8 May 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8759102 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDF6336
Flag
UNITED STATES
367473180
Maury page id
psix-48792

Inspections, by type

…with no type recorded20
…past their stated due date2
Years with a record 35 calendar years (1984–2025)
The 81 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Registered dimensions (L × B × D)176.0 ft × 70.0 ft × 11.5 ft
Registered tonnagegross 1,290 / net 1,290
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderZIGLER SHIPYARDS · MERMENTAU LA, UNITED STATES · built 1976
Hull materialSteel
PropulsionNone
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNORFOLK, VA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 1 April 2026 · expires 31 March 2027
Service, as the file records itIndustrial Vessel
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1290 - Regulatory (Subpart C or D), Gross Ton
1290 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDF6336MMSI 367473180 · active · compulsorily equipped · granted 4 November 2020, expires 4 December 2030
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 12

Inspection history · 81

8 May 2025 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8139253
11 March 2024 Periodic Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7874283
15 February 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7637076
4 August 2022 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7537096
7 June 2022 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7465174
25 February 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7401947
3 December 2020 COI Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7105501
25 November 2020 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7101845
25 August 2020 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7042537
27 May 2020 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 6961590
26 May 2020 COI Inspection · Deficiency Check · Internal Structural Exam · Drydock Extension
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6960904
10 March 2020 COI Inspection · Drydock Extension
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6923997
18 July 2019 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6797694
23 April 2019 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6667949
16 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6514097
10 July 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6473842
28 June 2018 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6456940
18 March 2018 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6375382
14 June 2017 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6176520
7 June 2017 Periodic Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6160489
2 May 2017 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6198194
28 March 2017 Internal Structural Exam · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6112259
30 November 2016 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6349868
13 June 2016 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5906477
13 July 2012 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4381626
27 June 2012 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4343010
11 May 2012 Hull Examination · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4308500
16 February 2010 Internal Structural Exam · Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3676803
27 May 2008 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3218565
10 July 2007 Annual Inspection
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2990274
21 March 2007 Hull Examination · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2891837
23 August 2006 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2756947
14 February 2006 Administrative Inspection
Administrative · USCG East District (dp) · USCG East District (CGD-E) · Activity 2585007
2 June 2005 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2362505
17 March 2005 Hull Examination · Internal Structural Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2313133
30 July 2004 Re-Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2155694
4 September 2003 In-Service Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1896493
2 April 2003 Hull Examination · Annual Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1767089
14 May 2002 Deficiency Check · Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1616599
30 July 2001 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1466790
15 June 2000 Hull Examination · COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1410353
8 November 1999 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 802852
26 July 1999 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 753412
22 July 1999 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 211060
23 October 1998 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1418418
14 October 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1438784
6 December 1997 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 52032
19 June 1997 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 404974
2 December 1996 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1363891
1 August 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1092842
25 June 1996 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1470921
8 April 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1385672
21 February 1996 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 658423
9 February 1996 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1435724
29 January 1996 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 387542
17 August 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1187605
30 January 1995 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 829880
22 August 1994 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 861845
10 January 1994 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1397994
24 May 1993 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1133639
26 April 1993 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1152177
9 February 1993 Drydock Extension
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 832183
21 December 1992 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1141407
7 February 1992 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 950335
7 February 1992 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1260904
31 December 1991 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1269971
12 December 1991 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 949669
7 January 1991 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1214531
1 June 1990 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1235470
23 February 1990 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1240481
21 February 1990 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1235274
8 January 1990 COI Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1223290
16 December 1988 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1042527
10 February 1988 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1019683
18 November 1987 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1333171
29 April 1987 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1325088
19 September 1986 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1003402
22 November 1985 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 991553
2 October 1985 Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 995006
30 September 1985 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1302779
3 October 1984 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1282294

Deficiency record · 120

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 June 2025 Resolved
For inspection procedures of Lifesaving appliances and arrangements, see subchapter W. Each lifejacket must have a lifejacket light approved under approval series 161.112 securely attached to the front shoulder area of the lifejacket. life jacket lights were expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2025
Resolved 10 July 2025
Resolution: replaced the lights
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 June 2025 No resolution recorded
Each firehose on each hydrant must have a combination solid stream and water spray firehose nozzle approved under subpart 162.027 of this chapter. 2 Nozzles installed were plastic and not type approved.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2025 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 June 2025 No resolution recorded
For inspection procedures of electrical engineering equipment and systems see subchapter J If twist-on type of connectors are used, the connections must be made within an enclosure and the insulated cap of the connector must be secured to prevent loosening due to vibration.(c) Twist-on type of connectors may not be used for making joints in cables, facilitating a conductor splice, or extending the length of a circuit. Multiple wire splices and twist on connectors present in crane cab.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2025 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 June 2025 No resolution recorded
An inspection either general or partial depending upon the circumstances shall be made whenever any important repairs or alterations are undertaken. Counter weight support structure was not repaired, repairs and marine inspector attendance required prior to use.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 26 June 2025 Resolved
A hydrostatic release unit used in a float-free arrangement must be approved under approval series 160.162. Hydrostatic release was not marked.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 26 June 2025
Resolution: vessel rep marked hydrostatic release.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 May 2025 Resolved
For inspection procedures of electrical engineering equipment and systems see subchapter J If twist-on type of connectors are used, the connections must be made within an enclosure and the insulated cap of the connector must be secured to prevent loosening due to vibration. Multiple connectors present on 3304 engine to include governor wiring and enclosure missing cover with oil present.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2025
Resolved 10 July 2025
Resolution: cover installed and crimp type connectors placed on governor
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 11 March 2024 Resolved
Each life raft or group of life rafts must be arranged for float-free launching. Hydrostatic release is missing from life raft.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2024
Resolution: Hyrdostatic release installed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 March 2024 Resolved
The lights and shapes specified in these Rules shall comply with the provisions of Annex I of these Rules (33 CFR part 84). The navigation lights are non operational. 33CFR83.20(e)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2024
Resolution: Nav lights working.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 11 March 2024 Resolved
The two means of escape shall be as remote as practicable so as to minimize the possibility of one incident blocking both escapes. Escape scuttle in the crane tun engineering space is inoperable. 46CFR92.10-10(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 April 2024
Resolution: New Scuttle installed.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 11 March 2024 Resolved
The two means of escape shall be as remote as practicable so as to minimize the possibility of one incident blocking both escapes. Escape scuttle to the fire pump/MSD space is wasted and not installed. 46CFR92.10-10(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 April 2024
Resolution: New Scuttle installed.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 11 March 2024 Resolved
Except as provided in paragraph (f) of this section, each opening in a watertight bulkhead must have a means to close it watertight. Crane tub/changing room has a 2 wire marine cable transit that is not watertight. 46CRF171.111(a)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2024
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 11 March 2024 Resolved
mats or gratings, suitable for the specific switchboard voltage must be installed for personnel protection at the front and rear of the switchboard and must extend the entire length of, and be of sufficient width to suit, the operating space. Matting behind crane switch board was missing and folded and deteriorated in the front. 46CFR111.30-11
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2024
Resolved 28 March 2024
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 11 March 2024 Resolved
At each inspection for certification and periodic inspection, the quarters, toilets, and washing spaces, galleys, serving pantries, lockers, etc., shall be examined by the inspector to be assured that they are in a sanitary condition. Vessel had gear adrift, loose items and severe lack of overall cleanliness in workspaces. 46CFR91.25(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2024
Resolution: Vessel cleaned enough to clear CG-835.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 March 2024 Resolved
All pressure vessels must be provided with protective devices. Air Compressor room, FWD air receiver relief valve did not re-seat. 46CFR54.15-5
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2024
Resolved 28 March 2024
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 March 2024 Resolved
All pressure vessels must be provided with protective devices. Air Compressor room. AFT are compressor was inoperable and unable to test relief valve. 46CFR54.15-5
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2024
Resolved 27 March 2024
Resolution: New Relief valve installed and tested.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 March 2024 Resolved
The frame or support of each semi-portable fire extinguisher required by Table 95.50–10(a) must be welded or otherwise permanently attached to a bulkhead or deck. Fire extinguisher locations #6 and #30 have fire extinguishers unmounted. 46CFR95.50-20(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2024
Resolved 28 March 2024
Resolution: Installed & mounted correctly.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 11 March 2024 Resolved
Distress signals. Each vessel must— Carry not less than 12 rocket parachute flares approved under approval series 160.136. Flares on board expired. 46CFR199.60(c)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2024
Resolved 27 March 2024
Resolution: New flares onboard.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 11 March 2024 Resolved
In general, compliance with the standards established by the American Bureau of Shipping. Engineering stores room bilge access showed signs of wastage. Descale and UT in 6" x 6" grid pattern. 46CFR92.01-10(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2024
Resolved 28 March 2024
Resolution: U/T Shots came back acceptable.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 11 March 2024 Resolved
All vessels shall have efficient guard rails or bulwarks on decks and bridges. Hand rails on ladder to crane are wasted and not to cropped and renewed where marked. 46CFR92.25-5(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2024
Resolved 27 March 2024
Resolution: Handrails welded.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 11 March 2024 Resolved
Lifebuoys. Each vessel must carry lifebuoys approved under approval series 160.150 as follows: Markings. Each lifebuoy must be marked in block capital letters. Port AFT lifebuoy is not marked. 46CFR199.70(c)(1)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2024
Resolved 27 March 2024
Resolution: Life bouy marked.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 March 2024 No resolution recorded
Nothing in this subpart shall be construed as limiting the inspector from making such tests or inspections as he or she deems necessary to be assured of the safety and seaworthiness of the vessel. Scow and anchor winch foundations showed significant signs of wastage and found to be suspect. Repair prior to operation. 46CFR91.25-50(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 11 March 2024 Resolved
Satisfactory means permanently attached, shall be provided for closing the openings of the air pipes. MSD vent does not have a means of closing. 46CFR42.15-50(a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 April 2024
Resolved 27 March 2024
Resolution: Ball check valve installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 11 March 2024 Resolved
Satisfactory means permanently attached, shall be provided for closing the openings of the air pipes. Potable water vent was wasted. 46CFR42.15-50(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2024
Resolved 27 March 2024
Resolution: Ball check valve installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 March 2024 Resolved
Non-Metallic flexible hose may only be used in lube oil, fuel oil and fluid power systems only where flexibility is required and in lengths not more then 30 inches. Vessel had approx 30 feet of flexible hose for lube oil permanently strapped to an electrical cable run in crane machinery space. 46CFR56.60-25(b)(4)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2024
Resolution: Ball check valve installed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 16 February 2023 Resolved
Each fire pump must be capable of delivering water simultaneously from the two highest outlets at 50 psi. Vessels fire main pipes were found with pin holes. Replace/repair fire main piping and demonstrate proper operation. 43CFR95.10-5(c)
Action required: 17 - Rectify deficiencies prior to departure
Due 16 February 2023
Resolved 24 March 2023
Resolution: Pipes renewed on deck and hydro'd satisfactory.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 February 2023 Resolved
General construction of the vessel shall be such as to minimize fire hazards. Vessels generator fuel return line leaking at the check valve. Replace/repair valve. 46CFR92.05-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 March 2023
Resolved 24 March 2023
Resolution: Replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 16 February 2023 Resolved
Suitable hand covers, guards, or rails shall be installed in way of all exposed and dangerous places. Vessel missing louvre on vent fan. Replace louvre. 46CFR92.25-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 March 2023
Resolved 24 March 2023
Resolution: Cover installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 February 2023 Resolved
Enclosures for each motor controller must meet IEC 60092-201 standards. Tag line winch motor controller unable to lock and was not watertight. Replace/repair motor controller. 46CFR111.70-3(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2023
Resolved 24 March 2023
Resolution: New motor controller box installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 February 2023 Resolved
Electric installations on vessels must ensure the protection of the crew from electrical hazards. Vessel had chaffed wired and unsecured heater IWA generator. Secure heater and replace wiring. 46CFR111.01(a)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2023
Resolved 24 March 2023
Resolution: Heater was secured and newly wired.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 February 2023 Resolved
Approved hand portable fire extinguishers shall be installed on all vessels. Vessels #17 fire extinguisher not properly mounted. Mount extinguishers in approved brackets. 46CFR95.15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2023
Resolved 24 March 2023
Resolution: Extinguisher mounted.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 16 February 2023 Resolved
No repairs or alterations affecting the safety of vessel with regard to the hull, machinery or equipment shall be mad with out the knowledge of the [name withheld] walkway deck entry to crane was found to be wasted. Submit repair proposal.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2023
Resolved 24 March 2023
Resolution: New diamond plate deck around 2nd level of crane was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 February 2022 Resolved
Each vessel must carry lifebuoys approved under approval series 160.150 as follows. Lifebuoys retroreflective tape was extremely faded; replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 March 2022
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 February 2022 Resolved
The lights prescribed in these Rules shall have an intensity as specified in Annex I, to these Rules so as to be visible from the following minimum ranges: (a) In a vessel of 50 meters or more in length: (ii) A sidelight, 3 miles. Vessel's starboard sidelight was faded; replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 March 2022
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 25 February 2022 Resolved
Vessel has been moored for over 6 months. Defer MOB drill to when the vessel gets underway. Provide proof of drill to OCMI.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 June 2025
Resolution: Vessel no longer has a rescue boat, but maintains standby vessel, eliminating the need for MOB drill
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 16 December 2020 Resolved
Exhaust pipe. (1) Exhaust pipe installations must conform to the requirements of ABYC P-1 and part 1, section 23 of NFPA 302 (both incorporated by reference; see 46 CFR 58.03-1) CAT 3606 has a major failure of the flex joint fron the turbo to the stack.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 December 2020
Resolution: Vessel replaced wasted flex joint
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 16 December 2020 Resolved
Operational readiness. Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. Life raft shell is damaged.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2020
Resolved 13 January 2021
Resolution: Vessel had life raft serviced.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 16 December 2020 Resolved
The purpose of this subpart is to establish requirements for oil spill response plans for nontank vessels. The development of a nontank vessel response plan prepares the vessel's crew and ship management to respond to an oil spill. NTVRP states when operating in Charleston COTP zone oil spill removal equipment will be provided for Average Most Probable Discharge, provide list showing all required equipment is available. NTVRP has Sector Charleston contact number listed incorrectly, number should be [phone withheld]. NTVRP record of changes section has last change occurring 2013 and cover page has 2018 listed, ensure all changes are incorporated into plan on barge. Provide current USCG approval letter for NTVRP. QI notification was not conducted as required by plan, notification was conducted and logged in presence of USCG. Provide evidence corrective actions were taken to comply with the requirements of NTVRP's.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 January 2021
Resolved 30 December 2020
Resolution: Vessel recieved the items specfied in the NTVRP.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 3 December 2020 Resolved
Each cargo vessel must carry an immersion suit approved under approval series 160.171 of an appropriate size for each person on board. Immersion suit were not of appropriate size for crew is present.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2020
Resolved 30 December 2020
Resolution: Vessel placed in service the corect size and number of immersion suits
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 3 December 2020 Resolved
Exhaust pipe. (1) Exhaust pipe installations must conform to the requirements of ABYC P-1 and part 1, section 23 of NFPA 302 (both incorporated by reference; see 46 CFR 58.03-1) CAT 3408 has multiple exhaust leaks
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 January 2021
Resolved 30 December 2020
Resolution: Replaced failed gaskets in the exhaust system.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 3 December 2020 Resolved
The applicable standards established by the ABS Steel Vessel Rules (incorporated by reference, see 46 CFR 58.03-1), may be used as the standard for the design, construction, and testing of main and auxiliary machinery except as modified in this subchapter. No proof of testing over-speed, Cooling water temp, Oil pressure was available
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 January 2021
Resolved 13 January 2021
Resolution: CAT technician conducted required testing with satisfactory results
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 June 2020 Resolved
Safety or relief valves on pressure vessels. (1) If your vessel's Certificate of Inspection is renewed annually, the marine inspector must check the settings of the safety or relief valves on all pressure vessels, except cargo tanks, at each inspection for certification. (2) If your vessel's Certificate of Inspection is renewed less often than annually, the marine inspector must check the settings of the safety or relief valves on all pressure vessels, except cargo tanks, twice every 5 years. No more than 3 years may elapse between any check and its immediate predecessor Relief valves have not been tested.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2020
Resolved 4 June 2020
Resolution: Installed new certified relief valves
14 - Pollution Prevention › 142 - MARPOL Annex II › Other (MARPOL Annex II)
Issued 1 June 2020 Resolved
A vessel owner or operator required by §155.5035 to have a vessel response plan (VRP) must conduct exercises as necessary to ensure that the VRP will function in an emergency. Vessel owners or operators must include both announced and unannounced exercises; and A vessel owner or operator must comply with the VRP exercise requirements of 33 CFR 155.1060. Missing quarterly QI drill, OSRO annual drill and triennial exercise.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2020
Resolved 21 June 2020
Resolution: Vessel rep provided proof of conducting drills as required.
14 - Pollution Prevention › 142 - MARPOL Annex II › Other (MARPOL Annex II)
Issued 1 June 2020 Resolved
he emergency means of shutdown required by §§154.550 and 155.780 of this chapter, as applicable, is in position and operable. Fuel transfer pump shut down button was stuck with corrosion.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 1 June 2020
Resolution: Disassembled and cleaned the corrosion.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 1 June 2020 Resolved
The master or person in charge shall ensure that tables indicating the maximum safe working loads for the various working angles of the boom, where the boom is rated at varying capacities depending on the radius, and the maximum and minimum radius at which the boom may be safely used, are conspicuously posted near the controls and are visible to the operator when working the crane. Was missing from crane operations location.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 1 June 2020
Resolution: Printed new loading information and placed in crane cab.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 26 May 2020 Resolved
MSD must be free of design defects such as rough or sharp edges that may cause bodily injuries or that would allow toxic substances to escape to the interior of the vessel. MSD tank has holes in the cover and possible other repairs not per manufacturers approval.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2020
Resolved 3 September 2020
Resolution: Vessel installed new type II MSD mfg by FAST serial no 23381
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Lighting (Working spaces)
Issued 26 May 2020 Resolved
Sufficient illumination must be provided by the emergency lighting source under emergency conditions to effect damage control procedures and to provide for safe egress from each space.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2020
Resolved 4 June 2020
Resolution: Installed 2 new lights in the cargo hold.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 23 April 2019 Resolved
Liferafts shall be installed in a float free configuration. Liferaft was not installed to be float free.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 23 April 2019
Resolved 23 April 2019
Resolution: Marine inspectors assisted crew in correcting deficiency and provided training.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 April 2019 Resolved
Fire hazards shall be minimized. Main diesel generator turbo was found with excessive oil coating the turbo.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 April 2019
Resolved 29 April 2019
Resolution: Turbo cleaned, plug replaced, SSDG run w/o evidence of oil leakage.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 April 2019 Resolved
Fire hazards shall be minimized. Fuel transfer piping was found leaking.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 April 2019
Resolved 29 April 2019
Resolution: Piping was renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 April 2019 Resolved
Each SSDG must be protected by overspeed trip not to exceed 15% of the rated speed. SSDG shall not be used until overspeed is repaired to the sat of the CG MI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2019
Resolved 29 April 2019
Resolution: Overspeed satisfactorily demonstrated.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 April 2019 Resolved
Fire hazards shall be minimized. Fuel hose shall have chafing installed.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 23 April 2019
Resolved 29 April 2019
Resolution: Chaffing was installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 April 2019 Resolved
Battery charging spaces shall be equipped with intrinsically safe equipment. Battery closet was fitted with non-intrinsically safe receptacle. Do not use charging until rectified.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 April 2019
Resolved 29 April 2019
Resolution: Electrical outlet was moved to outside of the hazardous space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 April 2019 Resolved
Pressure vessels shall be within corrosive limits. Pressure vessel in the MSD space is heavily corroded and presents a hazard. Repair or remove prior to using and within 7 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2019
Resolved 29 April 2019
Resolution: Pressure vessel was permanently removed from the vessel.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 April 2019 Resolved
Wiring on board shall be permanently installed. MSD and Shore tie lighting in the MSD space are not permanently installed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2019
Resolved 29 April 2019
Resolution: Wiring was made permanent.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 16 August 2018 Resolved
The vessel is currently broadcasting (1) Improper IMO Number.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 September 2018
Resolved 16 February 2023
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 28 June 2018 Resolved
Piping conveying vapors which temperatures exceed 150 degrees F shall be suitably insulated where necessary to preclude injury to personnel. SSDG exhaust manifold exposed to bare metal. 46 CFR 56.50-1(k)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2018
Resolved 10 July 2018
Resolution: Lagging properly installed.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 7 June 2017 Resolved
Barge does not have survival craft onboard. Barge is required to carry survival craft in accordance with 46 CFR 199.640(a) for 10 industrial personnel. Install required survival craft in accordance with Subchapter W to the satisfaction of an attending Marine Inspector. Prior to installation of survival craft; while the barge is manned, a rescue vessel shall be standing by in accordance with COI
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 August 2017
Resolved 2 August 2017
Resolution: Vessel rep installed a 12 person liferaft on the stern of the dredge for route shown on COI. Inspected type, installation, & servicing; all sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Automatic Heat Detectors
Issued 27 June 2012 Resolved
Heat Actuation Device (HAD) for pump room fixed CO2 system inop. Prove proper operation of actuator prior to operating machinery in pump room.
Action required: 705 - Other - as specified
Due 15 July 2012
Resolved 13 July 2012
Engineering › Diesel Engine (auxiliary) › Crankshaft
Issued 27 June 2012 Resolved
Rotating machinery guard missing on diesel generator located in crane machinery space. Reinstall guard.
Action required: 705 - Other - as specified
Due 15 July 2012
Resolved 13 July 2012
Lifesaving › Lifebuoys › Serviceable
Issued 27 May 2008 Resolved
Repair life rings, retro, grab lines and repair damage
Condition: Improper/Lack of Maintenance
Due 6 June 2008
Resolved 12 June 2008
Lifesaving › Rescue Boat › Hull (combination rigid/inflated)
Issued 27 May 2008 Resolved
Re-attach tube to frp hull on starboard side of rescue boat.
Condition: Improper/Lack of Maintenance
Due 6 June 2008
Resolved 12 June 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 May 2008 Resolved
Remove dead end wires and install covers on open juction boxes on overhead lights.
Condition: Improper/Lack of Maintenance
Due 6 June 2008
Resolved 12 June 2008
Electrical › Lighting (service) › Lighting Fixture
Issued 27 May 2008 Resolved
Replacing missing light covers in crane machinery room
Condition: Improper/Lack of Maintenance
Due 6 June 2008
Resolved 12 June 2008
Construction/Loadline › Structures › Door
Issued 27 May 2008 Resolved
Renew fuel room watertight door.
Condition: Improper/Lack of Maintenance
Due 6 June 2008
Resolved 12 June 2008
Fire Fighting › Fixed CO2 Fire Extinguishing System › Automatic Heat Detectors
Issued 27 May 2008 Resolved
Repair heat dectector.
Condition: Improper/Lack of Maintenance
Due 6 June 2008
Resolved 12 June 2008
Lifesaving › Launching Appliances › Davit
Issued 27 May 2008 Resolved
Weight test rescue boat davit due to heavy corrision.
Condition: Improper/Lack of Maintenance
Due 6 June 2008
Resolved 12 June 2008
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 27 May 2008 Resolved
Repair recepticle behind main generator
Condition: Improper/Lack of Maintenance
Due 6 June 2008
Resolved 12 June 2008
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Overspeed Device
Issued 27 May 2008 Resolved
Overspeed trips failed.
Condition: Improper/Lack of Maintenance
Due 6 June 2008
Resolved 12 June 2008
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 22 August 2006 Resolved
Fixed CO2 system in fuel oil room was overdue for annual and 12 year hydrostatic servicing.
Due 29 August 2006
Resolved 29 August 2006
Resolution: Replaced with newly serviced CO2 bottle.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 22 August 2006 Resolved
Fuel oil transfer hose was overdue for annual hydrostatic testing.
Due 22 September 2006
Resolved 5 September 2006
Resolution: Fuel oil transfer hose was hydrostatically tested IAW 33 CFR 156.170.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 22 August 2006 Resolved
Station Bill was not posted or on board vsl.
Due 22 September 2006
Resolved 6 September 2006
Resolution: Vsl purchased and installed new Station Bill.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 14 February 2006 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 7 March 2006
Resolved 13 April 2006
Resolution: information was sent to DAPI by [name withheld].
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 14 February 2006 Resolved
Company is required to have names of Substance Abuse Professionals in case employees need assistance. Employer was making it the responsibility of the employee to seek this information on their own, which is not the responsibility of the employee.
Due 7 March 2006
Resolved 13 April 2006
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 14 February 2006 Resolved
Company has not submitted MIS reports to US Coast Guard since conducting chemical testing. Follow-up to be conducted MIS due by March 15 2006.
Due 7 March 2006
Resolved 13 April 2006
Lifesaving › Lifebuoys › Serviceable
Issued 2 June 2005 Resolved
Replace two (2) lifebuoys due to unservicablity. Properly Place retro reflective material on two (2) buoys.
Due 7 June 2005
Resolved 6 June 2005
Resolution: Replaced two unserviceable life buoys and purchased and installed retro reflective material as required
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 2 June 2005 Resolved
3 Portable 15 lb CO2 extinguishers require Hydrostatic testing
Due 3 June 2005
Resolved 3 June 2005
Resolution: Replaced 3 Portable 15 lb CO2 extinguishers
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 2 June 2005 Resolved
Documentation of inspection of Fixed Fire Fighting system not available.
Due 7 June 2005
Resolved 6 June 2005
Resolution: Documentation of inspections provided
Operations/Management › Drills/Instruction › Abandon Ship
Issued 2 June 2005 Resolved
Documentation of Abandon Ship Drills not available
Due 7 June 2005
Resolved 6 June 2005
Resolution: Record of Drills provided
Operations/Management › Drills/Instruction › Fire
Issued 2 June 2005 Resolved
Documentation of Fire Drills not available
Due 7 June 2005
Resolved 6 June 2005
Resolution: Record of training provided
Lifesaving › Lifebuoys › Serviceable
Issued 30 July 2004 Resolved
REPLACE BOTH PORT AND STBD LIFERINGS
Due 7 August 2004
Resolved 11 August 2004
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 30 July 2004 Resolved
REPLACE TWO BROKEN STANCION ON STBD SIDE
Due 7 August 2004
Resolved 11 August 2004
Electrical › Electric Supply System (service) › Cable
Issued 30 July 2004 Resolved
REPLACE DEADEND WIRING AND INSTALL MISSING ELECTRICAL JUNCTION BOX COVER ON VESSEL
Due 7 August 2004
Resolved 11 August 2004
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 30 July 2004 Resolved
STORE PAINT PROPERLY
Due 31 July 2004
Resolved 30 July 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 July 2004 Resolved
INSTALL COVER FOR CEILING FAN LIGHT KIT IN CHIEF ENGINEER OFFICE.
Due 7 August 2004
Resolved 11 August 2004
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 30 July 2004 Resolved
INSTALL GAURD ON FAN IN CHIEF ENGINEER OFFICE
Due 7 August 2004
Resolved 11 August 2004
Electrical › Electric Generation Source (service) › Generator
Issued 30 July 2004 Resolved
INSTALL PROPER BREATHER ASSEMBLY ON #2 GENERATOR
Due 7 August 2004
Resolved 11 August 2004
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 30 July 2004 Resolved
PROVIDED DOCUMENTATION FOR FIRE EXTINGUISHER TESTINGA DN/OR HAVE BEEN TESTED AND MOUNTED THROUGHOUT THE VESSEL.
Due 7 August 2004
Resolved 11 August 2004
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 30 July 2004 Resolved
CLEAN AND PROVIDE LIGHTS FOR ALL LIFEJACKETS.
Due 7 August 2004
Resolved 11 August 2004
Electrical › Lighting (emergency)
Issued 2 April 2003 Resolved
E-light in lower aft store room improperly wired. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper Installation
Due 2 April 2003
Resolved 2 April 2003
Resolution: Properly wired light
Electrical › Electrical Distribution System (service)
Issued 2 April 2003 Resolved
Overhead cable runs in lower aft store room overhead loose LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Due 2 April 2003
Resolved 2 April 2003
Resolution: Reclamped
Electrical › Lighting (service) › Lighting Fixture
Issued 2 April 2003 Resolved
Two installed ceiling fans in lower store office space had improper lighting fixtures.
Condition: Improper Installation
Due 2 April 2003
Resolved 2 April 2003
Resolution: Removed improper fixtures.
Fire Fighting › Fire Pumps › Pressure
Issued 2 April 2003 Resolved
Discharge pressure gauge on installed fire pump inop
Condition: Improper/Lack of Maintenance
Due 2 April 2003
Resolved 2 April 2003
Resolution: Replaced gauge
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 2 April 2003 Resolved
Water lights for lifejackets improperly affixed.
Condition: Improper Installation
Due 2 April 2003
Resolved 2 April 2003
Resolution: Corrected
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 2 April 2003 Resolved
Retro tape on one life jacket faded
Condition: Unknown
Due 2 April 2003
Resolved 2 April 2003
Resolution: replaced tape
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 April 2003 Resolved
Water light inop
Condition: Unknown
Due 2 April 2003
Resolved 2 April 2003
Resolution: replaced battery
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 April 2003 Resolved
Port and starboard side lights and stern light inop
Condition: Improper/Lack of Maintenance
Due 2 April 2003
Resolved 2 April 2003
Resolution: repaired
Stability › Watertight Integrity
Issued 2 April 2003 Resolved
Forward and aft watertight doors to upper aft store room not sealing
Condition: Improper/Lack of Maintenance
Due 2 April 2003
Resolved 2 April 2003
Resolution: readjusted for proper seal.
Construction/Loadline › Hull › Hull Plating
Issued 2 April 2003 Resolved
Port Bow Strake shell plating damaged
Condition: Damaged By Earlier Event
Due 2 April 2003
Resolved 2 April 2003
Resolution: renewed plate
Electrical › Lighting (service)
Issued 14 May 2002 Resolved
Covers missing on three light fixtures in lower storeroom area. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Due 8 June 2002
Resolved 23 May 2002
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 14 May 2002 Resolved
COD not on board vessel.
Condition: Unknown
Due 8 June 2002
Resolved 14 May 2002
Lifesaving › Lifebuoys
Issued 14 May 2002 Resolved
Retro tape needs replacing on ring buoys
Condition: Unknown
Due 8 June 2002
Resolved 23 May 2002
Engineering
Issued 10 January 1994 Resolved
SHOW PROPER OPERATION OF THE D353 CAT GENERATOR, OVERSPEED DEVICE, LOW LUBESHUTDOWN AND HI-TEMP ALARM/SHUTDOWN.
Condition: Unknown
Due 10 January 1994
Resolved 10 January 1994
Fire Fighting
Issued 10 January 1994 Resolved
POST OPERATING INSTRUCTIONS FOR THE FIXED CO2 SYSTEM LOCATED IN THE FUEL OIL TRANSFER ROOM, MAIN DECK.
Condition: Unknown
Due 10 January 1994
Resolved 10 January 1994
Unknown
Issued 10 January 1994 Resolved
SHOW PROPER OPERATION OF BOTH RELIEF VALVES ON THE TWO SHIPS SERVICE AIR COMPRESSORS.
Condition: Unknown
Due 10 January 1994
Resolved 10 January 1994
Engineering
Issued 10 January 1994 Resolved
PROVIDE HEAT SHIELDING FOR THE GENERATOR EXHAUST PIPING IN WAY OF THE AIR COMPRESSOR FLAT IN THE CRANE.
Condition: Unknown
Due 10 January 1994
Resolved 10 January 1994
Construction/Loadline
Issued 8 January 1990 Resolved
REPAIR CRACKS IN HOUSE AT TOP CORNERS OF DOOR TO ENTRANCE OF MACHINERY SPACE.
Condition: Unknown
Due 8 January 1990
Resolved 8 January 1990
Electrical
Issued 8 January 1990 Resolved
REPAIR AND PROVE OVERSPEED TRIP ON AUX. GENERATOR.
Condition: Unknown
Due 8 January 1990
Resolved 8 January 1990
Construction/Loadline
Issued 8 January 1990 Resolved
PROPERLY INSTALL SOUNDING TUBES/DEVICES FOR FWD BALLAST TANKS.
Condition: Unknown
Due 8 January 1990
Resolved 8 January 1990
Accommodation/Occupational Safety
Issued 8 January 1990 Resolved
PROPERLY SUPPORT MSD PIPING FROM VALVE TO TANK.
Condition: Unknown
Due 8 January 1990
Resolved 8 January 1990
Fire Fighting
Issued 8 January 1990 Resolved
INSTALL FIRE EXTINGUISHER (BII) IN LOWER DAY ROOM.
Condition: Unknown
Due 8 January 1990
Resolved 8 January 1990
Unknown
Issued 30 September 1985 Resolved
POST A LOADING TABLE AT CRANE OPERATOR'S STATION.
Condition: Unknown
Due 30 September 1985
Resolved 30 September 1985
Fire Fighting
Issued 30 September 1985 Resolved
HAVE 2 FIRE EXTINGUISHERS IN ENGINE ROOM SERVICED.
Condition: Unknown
Due 30 September 1985
Resolved 30 September 1985
Electrical
Issued 30 September 1985 Resolved
REMOUNT OVERSPEED TRIP CONTROL BOX ON AUXILIARY GENERATOR.
Condition: Unknown
Due 30 September 1985
Resolved 30 September 1985
Navigation
Issued 30 September 1985 Resolved
PAINT RUNNING LIGHT SCREENS FLAT BLACK.
Condition: Unknown
Due 30 September 1985
Resolved 30 September 1985
Construction/Loadline
Issued 30 September 1985 Resolved
REMOVE ANCHOR WINCH COMPRESSED AIR TANK AND HYDRO TEST TO 250 PSI, FABRICATE AND INSTALL A NEW NAMEPLATE AND SCALE AND PAINT THE SAME.
Condition: Unknown
Due 30 September 1985
Resolved 30 September 1985
Deck/Cargo
Issued 30 September 1985 Resolved
RENEW CRANES ABS CERTIFICATE OR HAVE SURVEYED BY A OSHA APPROVED SHOP AND CERTIFICATED.
Condition: Unknown
Due 30 September 1985
Resolved 30 September 1985
Documentation
Issued 30 September 1985 Resolved
RENEW VESSEL'S FMC CERTIFICATE (OIL POLLUTION).
Condition: Unknown
Due 30 September 1985
Resolved 30 September 1985
Documentation
Issued 30 September 1985 Resolved
RENEW VESSEL'S FCC SATTION LICENSE.
Condition: Unknown
Due 30 September 1985
Resolved 30 September 1985
Construction/Loadline
Issued 30 September 1985 Resolved
STENCIL REMOTE STOPS FOR FUEL OIL AND COMPRESSOR.
Condition: Unknown
Due 30 September 1985
Resolved 30 September 1985
Construction/Loadline
Issued 30 September 1985 Resolved
INSTALL 30X30 MESH FLAME SCREENS ON LUBE OIL VENT AND DIESEL WINCH TANK VENT.
Condition: Unknown
Due 30 September 1985
Resolved 30 September 1985

Casualty record · 4

2 May 2017Routine · role: Involved in a Marine Investigation (non-casualty) · activity 6198194
18 March 2018Routine · role: Involved in a Marine Casualty · at GILMERTON HIGHWAY BRIDGE · activity 6375382
18 July 2019Routine · role: Involved in a Marine Casualty · at AICW ELIZABETH RIVER SO BRNCH I 64 DRAW BRIDGE · activity 6797694
4 August 2022Routine · role: Involved in a Marine Casualty · at GILMERTON HIGHWAY BRIDGE, NORFOLK #7 RAILROAD BRIDGE · activity 7537096
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.