6002

6002 is a 2004 industrial vessel. The Coast Guard has recorded 40 inspections since 2004, most recently in April 2025, along with 18 deficiencies and 5 casualty investigations between 2009 and 2024.

Records from 2004 to 2025. Most recent: inspection, 14 April 2025.

Built
2004
Last inspected
14 April 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the tow units, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 14 April 2025
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 22 calendar years (2004–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

668588
Flag
UNITED STATES
Maury page id
psix-668588

Documentation record

Registered dimensions (L × B × D)299.3 ft × 54.0 ft × 25.5 ft
Registered tonnagegross 3,678 / net 1,468
ITC dimensions (L × B × D)299.3 ft × 54.0 ft × 25.5 ft
ITC tonnagegross 3,678 / net 1,468
BuilderCORN ISLAND SHIPYARD, INC. · GRANDVIEW, IN, UNITED STATES · built 2004
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portNORFOLK, VA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 2 August 2025 · expires 31 August 2026
Service, as the file records itIndustrial Vessel
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it3678 - Convention (Subpart B), Gross Ton
1468 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

40 inspections, each with its date, unit and type; 18 deficiencies with the resolution recorded against each; 8 vessels inspected with it, by name and date; 5 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 8

Inspection history · 40

14 April 2025 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8111555
11 December 2024 Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8046116
29 October 2024 Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8026669
28 June 2024 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7944213
18 June 2024 Deficiency Check · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7937888
22 February 2024 Damage Survey
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7868690
22 February 2024 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7869411
25 October 2023 Administrative Inspection · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7814159
5 July 2023 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7733305
22 June 2023 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7720300
8 June 2022 Periodic Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7471616
25 March 2022 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7418723
2 August 2021 Administrative Inspection · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7275023
19 August 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7035136
31 March 2019 COI Inspection · Drydock Exam · Internal Structural Exam · Hull Examination · Administrative Inspection · Examination of Repairs
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6653443
21 August 2018 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6517911
18 July 2017 Periodic Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6212834
23 June 2017 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6187089
2 May 2017 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6198194
30 March 2017 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6115388
7 February 2017 Internal Structural Exam · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6083863
3 October 2016 Administrative Inspection · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6014480
9 October 2015 Deficiency Check · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5735771
2 March 2015 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 5077036
23 June 2014 Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4857334
12 September 2013 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4705580
22 August 2013 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4693450
9 October 2012 Administrative Inspection · MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4460920
2 February 2012 Internal Structural Exam · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4236563
11 October 2011 MARPOL Annex I Examination · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4165752
25 October 2010 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3878805
4 August 2009 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3570744
7 July 2009 Hull Examination · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3495691
7 July 2009 COI Inspection · MARPOL Annex I Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3519277
24 September 2008 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3331459
24 September 2007 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3065689
28 February 2007 Administrative Inspection · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2879347
20 December 2006 Administrative Inspection · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2878930
20 October 2005 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2518732
4 August 2004 Hull Examination · Initial Certification · Internal Structural Exam
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2155726

Deficiency record · 18

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 9 July 2024 Resolved
This subpart contains requirements for fluid power transmission and control systems and appurtenances. Except as otherwise provided for in this section, these requirements are applicable to the following fluid power and control systems. Hydraulic system is leaking and 5 gallon water jug was placed under to catch oil.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2024
Resolved 29 October 2024
Resolution: Recieved from Allen and Webb a report stating that was repaired and no leaks present.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 9 July 2024 Resolved
At each inspection for certification and periodic inspection the marine inspector shall conduct such tests and inspections of the main propulsion and auxiliary machinery and of its associated equipment, including the fluid control systems, as he feels necessary to check safe operation. Tach gauge on engine operating hydraulic pump was inopperable.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2024
Resolved 4 September 2024
Resolution: vessel replaced tach and verified operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 July 2024 Resolved
Industrial systems must meet Sections 111.12-1(b) and 111.12-1(c)—Prime movers. Engine wires are dead ended or open and 24v relay is hanging by the wires.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2024
Resolved 2 August 2024
Resolution: Wires were removed and relay suitbly mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 June 2024 Resolved
An electric apparatus must be designed, constructed, and installed to prevent any person from accidentally contacting energized parts. tli boxes were open and non crimp type connectors were used.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2024
Resolved 2 August 2024
Resolution: Crimp type conectors were used and covers replaced on tli boxes.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 22 February 2024 Resolved
The integrity of the hull and its structures must be maintained in compliance with the structural standards established by the American Bureau of Shipping (ABS); the hull has been breeched and the structures damaged during a marine casualty. Repairs are to be made in accordance with ABS standards; provide a repair proposal prior to commencing repairs.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 June 2024
Resolution: Deficiency rectified. ABS Finding No. 82.0
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 June 2023 Resolved
Electric installations on vessels must ensure maintenance of system integrity through compliance with the applicable system requirements (IEEE, NEC, IEC, etc.) to which plan review has been approved. Three twist-on type wire connectors were observed splicing wires together on the diesel prime mover (not within an enclosure) and the Murphy ignition control enclosure was hanging loosely, supported by a wire wrapped around one of the mounting bolts.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2023
Resolved 2 November 2023
Resolution: Twist type wire connectors replaced with crimp type connectors.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 22 June 2023 Resolved
A ship of 300 gross tons or more constructed after June 30, 1974 must have a fixed container or enclosed deck area under or around each fuel oil or bulk lubricating oil tank vent, overflow, and fill pipe, that: For a ship of 1600 or more gross tons has a capacity of one barrel. Drain plug for containment beneath fuel tank fill and vent was missing, rendering it ineffective.
Action required: 703 - Prior to bunkering operations
Due 22 June 2023
Resolved 5 July 2023
Resolution: Drain plug installed
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 2 August 2021 Resolved
Fuel oil fill transfer pipe containment was missing the plug.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 August 2021
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 5 October 2016 Resolved
Prior to conducting cargo operations provide proof of COFR.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 October 2016
Resolution: Varified in online data base that a new COFR has been issued.
Engineering › Diesel Engine (auxiliary) › Cylinder Head
Issued 9 October 2015 Resolved
Found diesel fuel and lubricating oil leaking from hydraulic pump prime mover. Complete repairs and prove proper operation to the attending USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 October 2015
Resolution: Witnessed proper operation of the hydraulic pump prime mover.
Electrical › Electrical Distribution System (service) › Fuse
Issued 25 October 2010 Resolved
Provide fuse or other means for circuit protection for cable labeled as "12 v radio".
Action required: 705 - Other - as specified
Due 25 November 2010
Resolved 8 November 2010
Resolution: Received Pics from O/Op showing the above deficiency cleared.
Engineering › Fuel Oil Service System › Hose
Issued 25 October 2010 Resolved
Replace fuel hose with approved SAE J 1942 hose and approved fittings.
Action required: 705 - Other - as specified
Due 25 November 2010
Resolved 8 November 2010
Resolution: Received Pics from O/Op showing the above deficiency cleared.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 25 October 2010 Resolved
Mark ring buoy with Homeport.
Action required: 705 - Other - as specified
Due 25 November 2010
Resolved 8 November 2010
Resolution: Received Pics from O/Op showing the above deficiency cleared.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 October 2010 Resolved
Vessel has allowed the Certificate of Inspection to expire, exceeding the 90 day window.
Action required: 705 - Other - as specified
Due 25 October 2010
Resolved 25 October 2010
Resolution: completed Inspection for Certification.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 28 February 2007 Resolved
Found 5 cut holes in bulkhead between fore and after port and starboard bow rakes; repaired
Condition: Unknown
Due 28 February 2007
Resolved 28 February 2007
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 20 October 2005 Resolved
Improper fuel hose fixed on the supply fuel line to the engine. Ensure proper marine grade fuel hose is used.
Condition: Improper Installation
Due 20 November 2005
Resolved 3 November 2005
Resolution: Engine fitted proper hose.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 20 October 2005 Resolved
Stencil vessel name on life buoy.
Condition: Improper/Lack of Maintenance
Due 20 November 2005
Resolved 3 November 2005
Resolution: Life buoy properly stenciled.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 October 2005 Resolved
Ensure operation of starboard navigation light.
Condition: Improper/Lack of Maintenance
Due 20 November 2005
Resolved 3 November 2005
Resolution: Nav light operable.

Casualty record · 5

4 August 2009Routine · role: Involved in a Marine Casualty · activity 3570744
22 August 2013Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 2 injured · activity 4693450
30 March 2017Routine · role: Involved in a Marine Casualty · activity 6115388
2 May 2017Routine · role: Involved in a Marine Casualty · activity 6198194
22 February 2024Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 7869411
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.