Inspection history · 59
17 February 2026
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 8302938
22 April 2025
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8117112
11 May 2022
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7449960
29 September 2021
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7322898
6 May 2020
Initial Certification · MTSA Verification · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6948998
19 July 2017
Industry Initiated Exam · MTSA Verification · MARPOL · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6216046
10 August 2016
Industry Initiated Exam · MTSA Verification
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 5969141
26 August 2014
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4972308
22 April 2013
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4603833
10 April 2013
Industry Initiated Exam · MTSA Verification · MARPOL · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4566242
12 March 2012
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4261769
3 February 2012
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4242082
2 February 2012
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4237497
11 January 2012
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4224176
1 March 2011
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3955757
12 January 2011
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3925800
26 November 2010
Damage Survey
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3899046
24 November 2010
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3898199
4 November 2010
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3885677
7 October 2010
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3866076
17 September 2009
MTSA Verification · Industry Initiated Exam · MARPOL · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3596564
3 May 2007
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 2936172
3 April 2007
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 2902175
1 February 2007
Uninspected Other · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 2869740
8 January 2007
Uninspected Other · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 2852088
6 January 2007
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 2852182
20 October 2005
Deficiency Check · MTSA Verification · Uninspected Other
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2519195
3 June 2005
Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2378501
2 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1957624
15 May 2003
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 1882063
30 April 2003
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 1793547
21 April 2003
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 1777764
24 April 2002
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 1608735
22 October 2000
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 283386
25 October 1999
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 434155
17 September 1998
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 420542
19 September 1997
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 408104
19 April 1997
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 169478
20 September 1996
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 40058
11 September 1996
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 395354
30 June 1996
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 72561
4 January 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 41474
3 January 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 57502
20 December 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 37619
2 October 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 173272
24 August 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 758204
20 August 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 197714
29 January 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 15830
27 January 1995
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 157937
8 July 1994
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 667527
7 July 1994
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 151441
7 July 1994
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 188816
18 April 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 44023
8 December 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 666437
30 November 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 91288
6 January 1993
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 132354
23 August 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 15732
12 March 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 121063
3 March 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 125170
Electrical › Lighting (service) › Lighting Fixture
Issued 1 February 2007
Resolved
Install metal cages on the overhead shower light globes or replace the glass globes with plastic ones.
Condition: Unknown
Due 1 March 2007
Resolved 30 March 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 1 February 2007
Resolved
Install a cover on the lower head, overhead light.
Condition: Unknown
Due 1 March 2007
Resolved 30 March 2007
Electrical › Electrical Distribution System (service) › Junction Box
Issued 1 February 2007
Resolved
Install a functional latch on the galley electrical panel box cover.
Condition: Unknown
Due 1 March 2007
Resolved 30 March 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 February 2007
Resolved
Properly secure the electrical outlet box wire on the portside of the front hold.
Condition: Improper Installation
Due 1 March 2007
Resolved 30 March 2007
Fire Fighting › Fire Main › Material
Issued 1 February 2007
Resolved
Properly secure the fire main pipe, stbd side, lower engine room.
Condition: Improper/Lack of Maintenance
Due 1 March 2007
Resolved 30 March 2007
Communications › Audible Communications › Bell
Issued 1 February 2007
Resolved
Post, when G/A sounds go to station, signs by every general alarm bell.
Condition: Improper/Lack of Maintenance
Due 1 March 2007
Resolved 30 March 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 February 2007
Resolved
Remove old battery charger wire located in the lower engine room.
Condition: Unknown
Due 1 March 2007
Resolved 30 March 2007
Engineering › Feedwater/Condensate Water System › Piping
Issued 1 February 2007
Resolved
Properly secure the port generator, coolant line.
Condition: Unknown
Due 1 March 2007
Resolved 30 March 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 February 2007
Resolved
Properly secure the wires on the aft engine room bulkhead.
Condition: Unknown
Due 1 March 2007
Resolved 30 March 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 February 2007
Resolved
Remove or properly wire the stbd main engine oil transfer pump.
Condition: Unknown
Due 1 March 2007
Resolved 30 March 2007
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 1 February 2007
Resolved
Update transfer procedures to include a section on communications as per 33CFR155.785
Condition: Unknown
Due 6 April 2007
Resolved 10 August 2007
Electrical › Electric Supply System (service) › Cable
Issued 8 January 2007
Resolved
Removed dead end (abandoned) wire in the overhead above the stbd main engine.
Condition: Improper/Lack of Maintenance
Due 21 January 2007
Resolved 8 January 2007
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 8 January 2007
Resolved
Properly secure the upper bridge stairway, hand rail.
Condition: Improper/Lack of Maintenance
Due 21 January 2007
Resolved 8 January 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 8 January 2007
Resolved
Repair the broken main deck, stbd side, forward, exterior light.
Condition: Damaged By Earlier Event
Due 21 January 2007
Resolved 8 January 2007
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 8 January 2007
Resolved
Properly ventilate the sewage space to remove excessive stench. Once ventilated, determine and repair source of odor.
Condition: Damaged By Earlier Event
Due 21 January 2007
Resolved 8 January 2007
Construction/Loadline › Hull › Bottom Plating
Issued 8 January 2007
Resolved
Determine source of the aft steering void, water leak and repair to the satisfaction of the attending Marine Inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 January 2007
Resolved 18 January 2007
Lifesaving › Lifebuoys › Approval
Issued 20 October 2005
Resolved
Two main deck fwd life ring buoys not CG approved.
Action required: 705 - Other - as specified
Due 3 November 2005
Resolved 3 November 2005
Lifesaving › Lifebuoys › Serviceable
Issued 20 October 2005
Resolved
Two pilot house life ring buoys unserviceable.
Action required: 705 - Other - as specified
Due 3 November 2005
Resolved 3 November 2005
Stability › Watertight Integrity › General
Issued 20 October 2005
Resolved
Properly repair stbd and port engine room watertight door.
Action required: 705 - Other - as specified
Due 3 November 2005
Resolved 3 November 2005
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 20 October 2005
Resolved
Replace stbd MDE exhaust lagging
Action required: 705 - Other - as specified
Due 3 November 2005
Resolved 3 November 2005
Documentation › Markings/Placards › Official Number (US)
Issued 20 October 2005
Resolved
Properly permanently attached vessels official number to the interior structure of the hull.
Action required: 705 - Other - as specified
Due 3 November 2005
Resolved 3 November 2005