Records from 1992 to 2026. Most recent: inspection, 30 June 2026.
Documentation record
Registered dimensions (L × B × D)54.7 ft × 21.0 ft × 5.7 ft
Registered tonnagegross 80 / net 59
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderINLAND MARINE INC · EVANSVILLE IN · built 1978
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLT LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 30 May 2026 · expires 31 May 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it59 - Regulatory (Subpart C or D), Net Ton
80 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 18
30 June 2026
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8345303
24 June 2025
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8166953
18 July 2024
Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7886527
26 April 2024
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7902058
11 July 2023
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7740242
4 April 2022
Initial Certification · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7492272
1 February 2022
Administrative Inspection
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7389278
4 August 2021
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7277215
22 April 2016
Industry Initiated Exam
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5864977
8 April 2016
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5851468
20 November 2013
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4759052
20 March 2013
Deficiency Check · DAPI Audit · Risk-based Targeted Exam
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4556987
28 December 2011
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4217610
30 November 2011
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4201855
3 December 2003
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1958658
21 August 2001
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 293197
18 November 1992
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 161641
6 March 1992
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 121091
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 30 June 2026
Resolved
Vessel must meet structural requirements for existing vessel. two small cracks on aft deck. Make repairs to satisfaction of attending MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 July 2026
Resolution: Uploaded objective evidence of structural repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 30 June 2026
Resolved
Machinery must be maintained per manufacturer's instructions.
Generator leaking oil from head gasket. Make repairs to satisfaction of attending MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 July 2026
Resolution: Uploaded objective evidence of generator leak repair.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 30 June 2026
Resolved
Equipment must be maintain to ensure safety. Stbd face wire damaged. Replace face wire.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 July 2026
Resolution: Uploaded objective evidence of new wire installation.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 June 2025
Resolved
The hull of each undocumented vessel must be marked with its name and hailing port. Makings must be in contrast to the background color. Name/hailing port not visible.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 July 2025
Resolution: Provided objective evidence or corrective action.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 June 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Pressure vessel electrical junction box is missing its cover.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 July 2025
Resolution: Provided objective evidence or corrective action.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 11 July 2023
Resolved
General alarm in places where hard to hear should be properly labeled with a sign that reads: “Attention General Alarm- When Alarm Sounds or Flashes Go to Your Station”. General alarms did not have proper labeling. Provide proper labeling.
46 CFR 143.235(b)(3)
Action required: 10 - Deficiency Rectified
Resolved 11 July 2023
Resolution: Placed placard above general alarm.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 July 2023
Resolved
Electrical components that pose an electrical hazard must be in an enclosure. The starboard generator local panel was missing a cover, exposing wires and creating electrical hazards. A cover shall be placed on the panel to prevent wire exposure.
46 CFR 143.400(g)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 July 2023
Resolution: Received objective evidence of replacement of the local panel cover.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 July 2023
Resolved
Electrical equipment must be maintained to ensure proper operation. The port generator had an exhaust leak. Replace the gasket and repair the leak.
46 CFR 143.205(c)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 July 2023
Resolution: Received objective evidence of repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 July 2023
Resolved
Each exhaust pipe from an internal combustion engine which is within reach of personnel must be insulated or otherwise guarded to prevent burns. The port generator exhaust did not have lagging. Lagging must be placed on the exhaust piping to prevent personnel injury.
46 CFR 144.830
Action required: 10 - Deficiency Rectified
Resolved 11 July 2023
Resolution: Placed lagging on exhaust piping.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 July 2023
Resolved
An exposed hazard such as rotating machinery must be protected by a cover guard or rail. The port engine has exposed rotating machinery. A guard must be placed over the rotating machinery to prevent personnel injury.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 July 2023
Resolution: Placed guard on rotating machinery.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 July 2023
Resolved
Each life jacket must have an approved light securely fastened to the front shoulder area of the life jacket. One life jacket had a light that was not working properly. A new approved light must be securely fastened to the should region on the PFD.
46 CFR 141.340(g)(1)
Action required: 10 - Deficiency Rectified
Resolved 11 July 2023
Resolution: Replaced light on PFD.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 July 2023
Resolved
If a dedicated storage cabinet is provided it must be secured to the vessel so that it does not move must be an approved flammable storage locker. The flammable locker provided was not an approved cabinet type. The flammable cabinet must be replaced with an approved type of locker.
46 CFR 142.225(c)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 July 2023
Resolution: Replaced existing flammable locker with approved type flammable locker.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 July 2022
Resolved
Each towing vessel must be equipped with at least one fire axe that is readily accessible for use from the exterior of the vessel. Had fire axe but was not mounted.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2022
Resolved 6 July 2022
Resolution: Fire axe was mounted.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 April 2022
Resolved
Each towing vessel must have either a self-priming, power-driven, fixed fire pump, a fire main, and hoses and nozzles in accordance with paragraphs (a) through (d) of this section; or a portable pump, and hoses and nozzles, in accordance with paragraphs (e) and (f) of this section. Pump suction line needs a strainer or weight added to keep in water. Pump suction hose was floating on top of water.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2022
Resolved 6 July 2022
Resolution: Received objective evidence that repairs were made.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 April 2022
Resolved
Fuel shutoff requirements, the valve must be installed in the fuel piping directly outside of the fuel oil supply tank. The valve is mounted correctly but one flange bolt was loose and all need to be checked for proper tightness.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2022
Resolved 6 July 2022
Resolution: Bolt and nut assemblies were checked and tightened.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 4 August 2021
Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the associated fleet that has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 90 days. If an inspection is not completed prior to this date, the action for this deficiency shall be changed to a 60 (Rectify deficiencies prior to movement) and the vessel may no long be permitted to operate.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 1 November 2021
Resolved 1 February 2022
Resolution: Organization has completed vessels COIs to meet 75%. The ORIOLE when COI issued will put their COI status at 100%.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 21 August 2001
Resolved
Vessels crew did not participate in drills onboard vessel.
Condition: Unknown
Due 21 September 2001
Resolved 20 March 2013
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 21 August 2001
Resolved
Vessel was missing it log of required tests.
Condition: Unknown
Due 21 September 2001
Resolved 20 March 2013