Records from 1992 to 2021. Most recent: inspection, 24 May 2021.
Inspection history · 50
24 May 2021
Administrative Inspection
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7205706
28 December 2020
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7117551
26 August 2019
Administrative Inspection
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6795156
8 August 2019
Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6776538
18 March 2019
Administrative Inspection · Initial Certification
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6645422
19 November 2018
Examination of Repairs · Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6584364
17 November 2018
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6588259
6 October 2018
Examination of Repairs · Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6558029
6 October 2018
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6559445
5 May 2017
Industry Initiated Exam
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6141717
26 February 2015
Administration
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5075745
10 July 2014
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4917718
27 October 2013
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4742554
5 June 2013
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4614428
15 May 2013
MTSA Verification · Industry Initiated Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4592093
18 January 2013
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 4518822
9 August 2012
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 4406489
26 January 2012
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4232186
8 August 2011
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4132809
10 June 2011
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4045651
15 April 2011
Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3987240
15 April 2011
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4013313
8 March 2011
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3961078
8 March 2011
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3975202
9 July 2010
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3791054
16 June 2010
Industry Initiated Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3768312
27 January 2010
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3673300
4 September 2009
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3601988
23 March 2009
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3888661
15 January 2009
Administration
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3394644
6 October 2008
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3368666
6 February 2008
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3143052
6 February 2008
Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3143076
26 August 2007
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3038574
25 August 2007
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3038562
30 August 2006
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2788462
18 May 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2383885
26 October 2004
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2228887
20 September 2004
MTSA Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2200366
17 September 2004
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2228712
24 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1990897
23 September 2003
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1983553
23 September 2003
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2386352
13 July 2003
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1852745
20 September 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 8399
10 March 2000
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 163889
14 October 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 181837
23 April 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 65380
5 April 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 74022
14 April 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 97814
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 August 2019
Resolved
Original deficiency found installed fire detection panel was not located at the pilot house. It was mounted near galley area. This is still an issue, however after further research and manufacturer phone calls current installed fire detection system does not meet regulation due to the fact unit is not an approved marine type system. Manufacturer stated it was designed for small to medium size commercial, industrial buildings. Manufacturer recommended a different system. Require system be replaced or provide information system meets regulation.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2019
Resolved 30 September 2019
Resolution: Vessel was able to supply proper information that the system installed was an authorized system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 18 July 2019
Resolved
The following systems must be equipped with gauges at the machinery location: Main engine lubricating oil pressure and main engine RPM. RPM was missing. Install gauge to meet 46cfr143.230(c)(1)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 August 2019
Resolved 14 March 2025
Resolution: Activity re-opened to clear overdue vessel deficiency. Actual proof of requirement resolution was not obtained. Activity closed.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 18 July 2019
Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. Missing vent covers. Install to meet cite 46cfr144.605.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 August 2019
Resolved 8 August 2019
Resolution: Picture sent of new ventilation cover installed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 July 2019
Resolved
The system is arranged and installed so a fire in the engine room automatically sets off alarms on a fire detection control panel at the operating station. Detection panel is located near galley area. Move or replace detection system to meet 46cfr142.330(4)-(7)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 August 2019
Resolved 26 August 2019
Resolution: This discrepency has been re-issued due to changes in description.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 October 2018
Resolved
While underway vessel had red gear issues with port MDE.
Vessel plans to be towed to local drydock for further inspection.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2018
Resolved 10 October 2018
Resolution: Repairs were made to the port MDE red gear, satisfactory.
17 September 2004Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 2228712
30 August 2006Routine · role: Involved in a Marine Casualty · activity 2788462
25 August 2007Routine · role: Involved in a Marine Casualty · activity 3038562
6 February 2008Routine · role: Involved in a Marine Casualty · activity 3143052
23 March 2009Routine · role: Involved in a Marine Casualty · activity 3888661
4 September 2009Routine · role: Involved in a Marine Investigation (non-casualty) · activity 3601988
27 January 2010Routine · role: Involved in a Marine Casualty · activity 3673300
8 March 2011Routine · role: Involved in a Marine Casualty · activity 3975202
15 April 2011Routine · role: Involved in a Marine Casualty · activity 4013313
10 June 2011Routine · role: Involved in a Marine Casualty · activity 4045651
8 August 2011Routine · role: Involved in a Marine Casualty · activity 4132809
26 January 2012Routine · role: Involved in a Marine Casualty · activity 4232186
27 October 2013Routine · role: Involved in a Marine Investigation (non-casualty) · activity 4742554
6 October 2018Routine · role: Involved in a Marine Casualty · activity 6559445
17 November 2018Routine · role: Involved in a Marine Casualty · activity 6588259
28 December 2020Routine · role: Acknowledged Pollution Source · serious marine incident, as classified · activity 7117551
28 December 2020Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 7117551
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source:
IIR, through 2026.