This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Maury page id
psix-24583
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. Only barges and towing
vessels are in this archive, so any other vessel type in the same activity does not
appear here: these lists are a floor, not a complete manifest.
One transverse frame, #4S void, with two inch deflection to bow, eight feet long, from centerline.
Action required: 705 - Other - as specified
Due 22 July 2020
Resolved 15 November 2022
Construction/Loadline › Hull › Weld
Issued 6 April 2012Resolved
Observed a 28" fracture along weld in port corner wrapper, which appears to be propagating into the side shell Issued CG-835 for vessel to effect temporary repairs, then proceed to Valero Port [name withheld] to offload cargo and once vessel is cleaned and certified gas free it is to proceed directly to Sienna Shipyard, Orange, TX to affect permanent repairs.
Action required: 705 - Other - as specified
Resolved 13 April 2012
Resolution: 28" fracture along port corner wrapper gouged and welded 36" in length. Inspected weld and witnessed satisfactory air test. Repair satisfactoy. Deficiency cleared.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 12 April 2010Resolved
Date for ISE expires on 06APR10.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 May 2010
Resolved 7 May 2010
Resolution: Vessel in Southwest Shipyard, Channelview, TX to undergo major exams.