MAURY USCG vessel records
← All vessels

RIVER DOCKS I

Built
1980
Last inspected
20 August 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 20 August 2025
…with no type recorded26
Operational controls None recorded without a removal date
Years with a record 25 calendar years (1992–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDF3830
185828
Flag
UNITED STATES
Maury page id
psix-185828

Documentation record

Registered dimensions (L × B × D)52.7 ft × 22.1 ft × 8.3 ft
Registered tonnagegross 83 / net 57
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLOUIS G ORTIS BOAT CO INC · KROTZ SPRINGS, LA, UNITED STATES · built 1980
Hull materialSteel
PropulsionUnknown
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCHICAGO, IL
Endorsements, as the file codes themcw_un
DocumentationValid · issued 6 December 2025 · expires 31 December 2026
Service, as the file records itTowing Vessel
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it83 - Regulatory (Subpart C or D), Gross Ton
57 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 54 inspections, each with its date, unit and type; 16 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 23 other vessels inspected with it; 2 other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 23

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

WINDY CITY Towing Vessel · MISLE 176831 · 3 September 2016 · activity 5999622902 Freight Barge · MISLE 207670 · 3 September 2016 · activity 5999622MISS ALLIE Towing Vessel · MISLE 992769 · 3 September 2016 · activity 5999622SCF 2218 Freight Barge · MISLE 598640 · 15 October 2008 · activity 3350074ACBL 440 Freight Barge · MISLE 213862 · 11 October 2004 · activity 2237923ACBL 3035 Freight Barge · MISLE 149400 · 6 March 2001 · activity 130487MEM 5164 Freight Barge · MISLE 489867 · 18 February 2001 · activity 15766DDC-31 Freight Barge · MISLE 21359 · 6 January 2001 · activity 66455MEM 466 Freight Barge · MISLE 457699 · 1 December 2000 · activity 44130SCNO 8154 Freight Barge · MISLE 195446 · 27 July 1998 · activity 92584IB 983 Tank Barge · MISLE 50196 · 3 March 1996 · activity 135955IB 965 Tank Barge · MISLE 52007 · 3 March 1996 · activity 135955ACBL 6043 Freight Barge · MISLE 184319 · 3 March 1996 · activity 135955OR 3579 Freight Barge · MISLE 138115 · 28 December 1995 · activity 150677MARGIT B Towing Vessel · MISLE 135324 · 25 March 1995 · activity 1004ACBL 2916 Freight Barge · MISLE 140594 · 25 March 1995 · activity 1004VL 81434 Freight Barge · MISLE 211985 · 23 January 1995 · activity 124366H Freight Barge · MISLE 212001 · 6 October 1994 · activity 165234M/G 170 Freight Barge · MISLE 114194 · 5 October 1994 · activity 172139M/G 526 * Freight Barge · MISLE 172422 · 5 October 1994 · activity 172139ACBL 4348 Freight Barge · MISLE 182870 · 5 October 1994 · activity 172139ACBL 1281 Freight Barge · MISLE 111888 · 3 January 1994 · activity 78259TRL 14 Freight Barge · MISLE 374992 · 16 January 1992 · activity 118811

Inspection history · 54

20 August 2025 COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8214072
8 May 2025 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8130815
15 April 2024 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7895730
22 May 2023 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7695016
10 May 2023 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7685124
13 January 2023 MTSA Verification · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7621130
19 December 2022 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7611363
5 October 2022 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7571221
20 July 2021 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7263041
1 October 2020 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7093852
26 November 2019 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6863234
17 October 2019 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6837065
9 July 2019 Initial Certification · DAPI Audit · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6743173
14 November 2018 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6580474
17 May 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6416959
3 September 2016 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5999622
10 January 2014 Administration
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4780739
21 August 2013 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4699644
26 June 2013 Industry Initiated Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4634337
4 June 2012 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4333997
1 May 2012 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4299831
1 May 2012 MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4299840
2 February 2012 DAPI Audit
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4237185
30 August 2010 Industry Initiated Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3838124
23 June 2010 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3775059
16 April 2010 Industry Initiated Exam · MARPOL
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3719616
15 October 2008 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3350074
6 October 2006 Annual Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2795149
11 October 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2237923
23 June 2004 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2110636
17 June 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2101504
9 February 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2005374
24 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1977546
26 September 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 125081
6 March 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 130487
18 February 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 15766
6 January 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 66455
1 December 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 44130
27 July 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 92584
1 November 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 82298
19 April 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 669318
19 March 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 152253
3 March 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 135955
28 December 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 150677
17 October 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 184278
12 April 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 43431
25 March 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1004
23 January 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 124366
6 October 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 165234
5 October 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 172139
29 May 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 161054
3 January 1994 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 78259
29 April 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 181017
16 January 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 118811

Deficiency record · 16

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 May 2025 Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must: (1) Be maintained to ensure proper operation. Vessel is currently rebuilding main engine and is required to have a CG COI inspection prior to operations and transition to TMSM inspection option.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2025
Resolution: Vessel was issued COI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 January 2023 Resolved
PORT GENSET, STBD GENSET, AND STBD MDE REQUIRE METAL F/O FILTER BOWLS UNDER THEIR FILTERS.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 February 2023
Resolved 20 January 2023
Resolution: Metal F/O filter bowls have been installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 January 2023 Resolved
THREE POWER PANELS IN THE ENGINE ROOM NEED TO BE LABELED WITH VOLTAGE RATING ON PANEL ENCLOSURES.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 February 2023
Resolved 20 January 2023
Resolution: All power panels have their voltage rating labeled on front covers.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 17 January 2023 Resolved
PRESSURE VESSEL/AIR RECEIVER HAS A VALVE INSTALLED BETWEEN THE TANK AND THE TANKS PRESSURE RELIEF DEVICE. INSTALL RELIEF DEVICE WITH NO POSSIBLE OBSTRUCTIONS OT THE TANK.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 February 2023
Resolved 20 January 2023
Resolution: Valve between tank and relief device has been removed.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 17 January 2023 Resolved
THE F/O EMERGENCY SHUTOFF VALES NEED TO BE LABELED TO SHOW THAT THEY ARE F/O SHUTOFF VALVES.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 February 2023
Resolved 20 January 2023
Resolution: Proper label for emergency F/O shutoff valves has been installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 January 2023 Resolved
A POWWER PANEL IN THE ENGINE ROOM HAS AN OPEN/EXPOSED CIRCUIT BREAKER SLOT THAT NEEDS TO BE COVERED.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 February 2023
Resolved 20 January 2023
Resolution: Exposed circuit breaker slot has been filled with a spare.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 January 2023 Resolved
NAV LIGHTS ARE NOT HORIZONTALLY INSTALLED AND HAS PAINT COVERING LENS. AMBER LIGHTS ARE NOT SPACED 1 METER APART.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 February 2023
Resolved 20 January 2023
Resolution: NAV lights have been installed horizontally, spaced appropriately, and all paint removed from the lens.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 17 January 2023 Resolved
PROVIDE TRAINING IN FIRE FIGHTING TO ALL CREW AND PROVIDE TRAINING ON ALL FIRE FIGHTING EQUIPMENT/INSTALLATION USAGE.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 January 2023
Resolution: CFR fire fighting training requirements/standards have been completed to the satisfaction of attending Marine Inspectors.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 January 2023 Resolved
PROVIDE CERTIFICATE OF INSPECTION ONBOARD VESSEL.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 January 2023
Resolution: Vessel completed COI Renewal Inspection and was issued new COI.
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 17 January 2023 Resolved
PROVIDE WORK VESTS APPROVED BY THE COMMANDANT UNDER 46 CFR 160.053(a) OR REQUEST A WAIVER TO USE TYPE III VESTS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 February 2023
Resolved 9 February 2023
Resolution: Work vests approved by USCG Commandant were provided to vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 January 2023 Resolved
PROVIDE NEGATIVE DRUG TESTS FOR: BRETT BAILY, RICH PALMIER, DARRELL KESSLER, GERALD SARABIA, AND ANY OTHER EMPLOYEE INVOLVED IN THE SAFETY OF THE VESSEL PRIOR TO EMPLOYING THEM AS A CREWMEMBER.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 February 2023
Resolved 10 May 2023
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 17 January 2023 Resolved
PROVIDE A DOCUMENTED MAINTENANCE PLAN FOR THE FUEL SYSTEMS FOR THE MAIN ENGINES AND GENERATORS.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 February 2023
Resolved 10 May 2023
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 17 January 2023 Resolved
PROVIDE WRITTEN HEALTH AND SAFETY PLAN.
Action required: 10 - Deficiency Rectified
Resolved 17 January 2023
Resolution: Vessel provided plan prior to Inspectors departure.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 January 2023 Resolved
PROPERLY LABEL OR COLOR CODE ISOLATION VALVES FOR FLAMMABLE LIQUIDS, SEAWATER COOLING, AND FIRE FIGHTING SYSTEM PIPING.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 February 2023
Resolved 22 May 2023
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 October 2022 Resolved
A towing vessel choosing the Coast Guard option must undergo annual inspection within 3 month before or after teh COI anniversary date. Based on the vessel's anniversary date of 11July2019, the annual inspection must be conducted prior to 11Oct2022. The vessel may not operate past 11Oct2022 until the annual examination has been completed by the Coast Guard.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 January 2023
Resolution: Vessel completed a COI Renewal Inspection, SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 July 2019 Resolved
Document fuel system maintenance plan
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 August 2019
Resolved 17 October 2019
Resolution: New fuel maitenance plan in place and documented

Recorded names · 2

JACQUE R (2002), JACQUE R. (2004–2008). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.