Records from 1993 to 2011. Most recent: inspection, 13 January 2011.
Inspection history · 11
13 January 2011
DAPI Audit · Industry Initiated Exam · MTSA Verification
Physical examination · USCG Heartland District (dp) · USCG Heartland District (CGD-H) · Activity 3928927
10 May 2007
Uninspected Other
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2975493
11 October 2006
MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2798726
18 August 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2752211
30 June 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2408853
7 March 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2304993
1 April 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2036261
3 June 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1625399
28 October 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 33831
13 April 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 665601
27 January 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 89715
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 10 May 2007
Resolved
Missing EAP hotline Info on vessel
Condition: Improper/Lack of Maintenance
Due 15 May 2007
Resolved 18 May 2007
Resolution: Deficiency was corrected according to email from company.
Personnel › Training › Fire Fighting Basic
Issued 10 May 2007
Resolved
No proof of fire fighting training onboard. Conduct training within 14 days.
Condition: Improper/Lack of Maintenance
Due 24 May 2007
Resolved 18 May 2007
Resolution: Deficiency was corrected according to email from company.
Navigation › Piloting/Steering › Marine Charts
Issued 10 May 2007
Resolved
Missing marine charts of the area.
Condition: Improper/Lack of Maintenance
Due 12 May 2007
Resolved 18 May 2007
Resolution: Deficiency was corrected according to email from company.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 10 May 2007
Resolved
Missing Coast Guard light list on vessel.
Condition: Improper/Lack of Maintenance
Due 12 May 2007
Resolved 18 May 2007
Resolution: Deficiency was corrected according to email from company.
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 10 May 2007
Resolved
Missing Local notice to mariners on vessel
Condition: Improper/Lack of Maintenance
Due 12 May 2007
Resolved 18 May 2007
Resolution: Deficiency was corrected according to email from company.
Navigation › Piloting/Steering › Magnetic Compass
Issued 10 May 2007
Resolved
Vessel is missing the magnetic compass or swing meter.
Condition: Improper/Lack of Maintenance
Due 15 May 2007
Resolved 18 May 2007
Resolution: Deficiency was corrected according to email from company.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 10 May 2007
Resolved
Vessel name and hailing port not clearky visable on stern.
Condition: Improper/Lack of Maintenance
Due 15 May 2007
Resolved 18 May 2007
Resolution: Deficiency was corrected according to email from company.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 10 May 2007
Resolved
Vessel is missing their MSD placards.
Condition: Improper/Lack of Maintenance
Due 15 May 2007
Resolved 18 May 2007
Resolution: Deficiency was corrected according to email from company.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 10 May 2007
Resolved
Vessel is missing its overboard discharge valve for the MSD.
Condition: Improper/Lack of Maintenance
Due 12 May 2007
Resolved 18 May 2007
Resolution: Deficiency was corrected according to email from company.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 May 2007
Resolved
Vessel is missing guards on machinery on the bow and in the engine room
Condition: Improper/Lack of Maintenance
Due 15 May 2007
Resolved 18 May 2007
Resolution: Deficiency was corrected according to email from company.
Electrical › Lighting (service) › Lighting Fixture
Issued 10 May 2007
Resolved
Light guards and globes missing on vessel
Condition: Improper/Lack of Maintenance
Due 12 May 2007
Resolved 18 May 2007
Resolution: Deficiency was corrected according to email from company.