SUSAN W

SUSAN W is a 1982 towing vessel. The Coast Guard has recorded 35 inspections since 1992, most recently in January 2026, along with 19 deficiencies, 2 operational controls and 3 casualty investigations between 2004 and 2025.

Records from 1992 to 2026. Most recent: inspection, 28 January 2026.

Built
1982
Last inspected
28 January 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 28 January 2026
…with no type recorded17
Operational controls None recorded without a removal date
Years with a record 18 calendar years (1992–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8968789
WCW4123
207251
Flag
UNITED STATES
Maury page id
psix-207251

Documentation record

Registered dimensions (L × B × D)104.0 ft × 34.0 ft × 12.5 ft
Registered tonnagegross 98 / net 67
ITC dimensions (L × B × D)104.0 ft × 34.0 ft × 12.5 ft
ITC tonnagegross 377 / net 113
BuilderMODERN MARINE POWER INC · HOUMA, LA, UNITED STATES · built 1982
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 7 November 2025 · expires 31 December 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it377 - Convention (Subpart B), Gross Ton
98 - Regulatory (Subpart C or D), Gross Ton
113 - Convention (Subpart B), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 11

Inspection history · 35

28 January 2026 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8303126
28 May 2025 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8146279
21 April 2025 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8115927
21 April 2025 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8116893
1 April 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8095203
4 April 2024 Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7889970
13 June 2023 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7713804
14 November 2022 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7594208
5 July 2022 Administrative Inspection · Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7542701
6 July 2021 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7247048
1 July 2021 ISM Oversight · Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7652222
21 May 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7202624
29 June 2020 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6990850
6 March 2019 Initial Certification · Deficiency Check · MTSA Verification · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6640562
9 February 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5811902
7 September 2011 DAPI Audit · MTSA Verification · Deficiency Check · Industry Initiated Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4139143
1 September 2006 MTSA Verification · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2783015
24 July 2006 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2723341
24 July 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2723377
4 February 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2006332
18 November 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1951430
17 June 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1632005
3 June 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1625399
11 October 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 7413
2 April 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 640175
9 March 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 15185
9 March 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 214290
9 March 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 223863
23 October 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 87382
17 December 1993 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 645274
7 December 1993 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 475263
22 August 1993 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 219133
23 June 1993 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 694173
13 June 1993 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 131640
1 September 1992 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 42372

Deficiency record · 19

02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 16 March 2026 Resolved
Steering systems must meet ABS Rules for Building and Classing Steel Vessels under 90 Meters (295 Feet) in Length (incorporated by reference, see § 136.112 of this subchapter), Part 4, Chapter 3, Section 3. Vessel's rudder post packing gland hardware and structural ring was severally corroded. Provide repair proposal. 46 CFR 143.550
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2026
Resolved 18 March 2026
Resolution: Recieved documentation and evidence of repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 16 March 2026 Resolved
Pressure vessel relief valves shall be tested Twice every 5 years, with no more than 3 years elapsing since last test. Vessel had two tags on the installed pressure relief valve indicating two different pressures, only one report could be produced to show the testing was done in 2023. Relief valves shall be tagged and tested with the correct pressure. 46 CFR 143.245(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2026
Resolved 7 April 2026
Resolution: recieved picture evidence of correction
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 28 January 2026 Resolved
Each towing vessel operating in oceans and coastwise service must have a line throwing appliance approved under approval series 160.040. Four rocket projectiles, each complete with bridle and leader of fire-resistant materials. Two of the projectiles shall be of the buoyant type. 46 CFR 141.385
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2026
Resolved 8 April 2026
Resolution: recieved picture evidence of correction
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 28 May 2025 Resolved
a) Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. b) Alarms must: (1) Be visible and audible at each operating station. The alarm located at the operating station may be a summary alarm; if the alarm at the operating station is a summary alarm, the specific alarm condition must be indicated at the machinery or bilge location. MI observed no alarms, visible or audible, at either operating station. Vessel must repair alarm panel at each operating station (pilothouse and aft). If aft operating station is not to be used it must be secured and removed from service. 46CFR143.230
Action required: 60 - Rectify deficiencies prior to movement
Due 30 June 2025
Resolved 9 June 2025
Resolution: MI attended the vessel and witness sat. op. of alarms
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 April 2025 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Vessel experienced loss of steering around LMR 138. Vessel will provide technicians report and statement from master attesting to what occurred as well as the proper repair, testing, and operation of the steering system prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 April 2025
Resolution: Steering Ram replaced. Signed letter from Capt. attesting to proper function of steering system along with a video to the duty phone.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 June 2023 Resolved
Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve. One unlabeled breaker (number 23) was present and 03 energized breakers were labeled "blank". Correctly label all breakers and secure power to any blank breakers.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2023
Resolved 21 June 2023
Resolution: Vessel rep. sent in photos of panel labeled properly and spare breakers secured.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 June 2023 Resolved
Electrical components that pose an electrical hazard must be in an enclosure. Dead end wires and unused equipment were found in engine room and forward compartment. Remove dead end wires or secure in a junction box. Ensure power to unused equipment is secured if the equipment and cabling is not removed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2023
Resolved 21 June 2023
Resolution: Vessel crew removed dead end wires.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 June 2023 Resolved
Piping for flammable or combustible liquid, seawater cooling, or firefighting systems must be fitted with isolation valves that are clearly marked by labeling or color coding that enables the crew to identify its function. One valve in engine room was not labeled. Identify and label valve. Dead end pipe was present in engine room near forward bulkhead. Identify pipe usage and label/cap correctly, or remove pipe.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2023
Resolved 21 June 2023
Resolution: Vessel crew labeled all stop valves for the bilge system.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 November 2022 Resolved
Vessel must be provided with a installed fire suppression system for the vessel's engine room. Vessel's installed CO2 system had 02 corroded and worn hoses.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 November 2022
Resolved 17 November 2022
Resolution: Vessel purchased new hoses from Hiller and replaced all hoses.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 November 2022 Resolved
Vessel must have a fire detection system. Vessel's fire detection panel had a battery trouble light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2022
Resolved 1 December 2022
Resolution: Vessel sent in report of servicing for the fire detection system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 November 2022 Resolved
Vessel must have a bilge pump for dewatering. Vessel's bilge/ballast pump had a leak.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2022
Resolved 1 December 2022
Resolution: Vessel sent in servicing report for the pump overhaul.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 July 2021 Resolved
Pressure vessel's over 5 Cubic feet and over 15 pounds per square inch maximum allowable working pressure must be equipped with one or more spring-loaded relief valves and be inspected twice in five years with no more than 3 years elapsing since last test. Vessels forward air compressor tank has spring loaded relief valve set at 250psi, system's MAWP is 200psi, thus exceeding the 200psi overage by more than 10 percent. Vessel is able to operate with one tank and is able to isolate the other tank with the out of range valve. Vessel shall operate solely with the aft tank with the properly adjusted valve. Only in emergencies should the forward tank be used until the valve is adjusted or replaced with correctly adjusted valve PSI relief.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 August 2021
Resolved 15 July 2021
Resolution: Safety valve was replaced with a curently tested one that was ajusted to MAWP of 200PSI.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 16 July 2020 Resolved
Vessel fire detection system was not serviced in the last 12 months, vessel is required to have system vessel serviced by a third party.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 August 2020
Resolution: System was serviced by hiller, all sat. Servicing report attached.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 16 July 2020 Resolved
Line throwing device was missing the required 1500ft auxiliary line, vessel is required to provide required auxiliary line.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 August 2020
Resolution: Provided photo evidence of required aux line for throwing device.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 29 June 2020 Resolved
UPV located in engine room had a pressure relief valve that was not serviced since 2015. Vessel is required to either replace valve or have it serviced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 August 2020
Resolution: Provided photo evidence of new relief valve on UPV.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 24 April 2019 Resolved
E/R general alarm lens missing an on order.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 May 2019
Resolution: new one installed.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 24 April 2019 Resolved
Device had no propellant canister so it could not be armed or used.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 May 2019
Resolution: installed and other three ordered.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 April 2019 Resolved
Generator windings has excessive dust build up. Windings could not bee seen.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 May 2019
Resolution: cleaned
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 6 March 2019 Resolved
Vsl has no means to recover a person from the water with the normal operating draft freeboard of 3' 9". This seems to be an oversight in M.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 May 2019
Resolution: Retreaval system provided and crew trained on its use.

Casualty record · 3

4 February 2004Routine · role: Transiting Vicinity of Primary Subject · activity 2006332
9 February 2016Routine · role: Involved in a Marine Investigation (non-casualty) · activity 5811902
21 April 2025Routine · role: Involved in a Marine Casualty · activity 8116893
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.