Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH6875
208841
Flag
UNITED STATES
Maury page id
psix-208841

Documentation record

Registered dimensions (L × B × D)73.8 ft × 23.0 ft × 10.3 ft
Registered tonnagegross 140 / net 95
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCENAC SHIPYARD · HOUMA, LA, UNITED STATES · built 1982
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNORFOLK, VA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 29 June 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it140 - Regulatory (Subpart C or D), Gross Ton
95 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 38 inspections, each with its date, unit and type; 43 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 6 other vessels inspected with it; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 6

Inspection history · 38

28 April 2026 COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8354216
27 October 2025 Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8269846
24 July 2025 Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8192035
12 June 2024 Internal Structural Exam · Annual Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7932793
5 July 2023 Annual Inspection · MTSA Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7733828
25 May 2023 Administrative Inspection
Administrative · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7696718
21 July 2022 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7512232
30 April 2021 DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7169128
21 December 2019 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6890207
12 August 2017 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6266545
1 July 2014 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4908301
15 August 2013 Spot Check (Safety)
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4690331
14 August 2013 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4694380
17 January 2013 MTSA Verification · DAPI Audit · Industry Initiated Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4517191
12 December 2012 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4514387
26 July 2012 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4391512
5 April 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2936302
18 August 2006 Uninspected Other · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2754657
11 April 2005 Administrative Inspection
Administrative · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2331298
2 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1965181
12 June 2003 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1818671
20 September 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1053919
19 April 2000 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1049034
18 April 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 90923
11 April 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 111296
1 April 1999 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 722057
18 December 1998 Uninspected Towing Vessel
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 810138
17 December 1998 Uninspected Towing Vessel
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 810126
16 December 1998 Uninspected Towing Vessel
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 809178
14 December 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 77725
29 October 1996 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 396918
22 April 1996 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 25356
1 May 1995 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 752005
25 April 1995 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 208345
8 July 1987 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 317468
10 March 1987 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 314999
16 December 1986 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 313539
10 June 1986 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 309952

Deficiency record · 43

07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 28 April 2026 Resolved
Valve must be operable from a safe place outside the space where the valve is installed. MI observed starboard fuel shutoff valve inoperable. 46 CFR 143.260(d)
Action required: 60 - Rectify deficiencies prior to movement
Due 12 June 2026
Resolved 29 April 2026
Resolution: O/O installed a mechanical system to the starboard fuel shutoff valve. MIs witnessed successful operation of stbd fuel shutoff valve.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 24 July 2025 Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover and the valve must be operated from a safe place outside the space installed. Port fuel shutoff valve was inoperable at the time of testing. O/O to make repairs to fuel shut off valve to satisfaction of MI. 46CFR143.260
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 July 2025
Resolution: MIs witnessed successful operation of port/stbd fuel shutoff valves.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 July 2025 Resolved
Electrical connections must be suitable installed to prevent them from coming loose through vibration or accidental contact. Multiple battery bank terminal connections found in E/R were installed with wingnuts. Provide suitable connections not susceptible to loosen due to vibration to satisfaction of MI. 46CFR143.400(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 August 2025
Resolved 28 July 2025
Resolution: Completed to satisfaction of MI.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 July 2025 Resolved
Vessels using water from a PWS as ballast must maintain a record of which PWS they received the water and a receipt, invoice, or other documentation from the PWS indicating that water came from that system. Vessel was using forward compartment as ballast and spare potable water. Vessel manager to provide documentation to the satisfaction of MI. 33CFR151.1510(a)(4)
Action required: 705 - Other - as specified
Resolved 27 October 2025
Resolution: Received reports includiing policy and procedures for BWM to satisfaction of MI.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 24 July 2025 Resolved
Each towing vessel must be capable of preventing all oil spills from reaching the water during transfers by: pre-closing the scuppers if towing vessel is so equipped. Stbd fwd containment is missing mechanical scupper plug/ Provide plug as designed. 46CFR140.655(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 August 2025
Resolved 25 July 2025
Resolution: MIs visually verified proper scupper plugs were installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 July 2023 Resolved
Stowage positions for lifejackets and immersion suits stowed in a berthing space or stateroom and all lifejacket containers must be marked in block capital letters and numbers with the minimum quantity, and identity. One lifejacket was under accounted for during the inspection and eventually found in a cabinet. 46 CFR 141.340(h)/46 CFR 199.70(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 August 2023
Resolved 10 July 2023
Resolution: Received objective evidence via photos that lifejacket locations are labeled.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 5 July 2023 Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. The emergency lighting fixture is installed by a plug into an outlet in the chart room. 46 CFR 143.400(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 August 2023
Resolved 10 July 2023
Resolution: Received objective evidence emergency lighting plug was removed and hard wired to a junction box.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 July 2023 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Both main deck berthing’s had multiple power strips “daisy chained” together plugged into one outlet. 46 CFR 143.400(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 August 2023
Resolved 10 July 2023
Resolution: Witnessed daisy chains and power strips removed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 5 July 2023 Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. The STBD generator was missing 3-4’ of exhaust lagging/insulation. 46 CFR 143.220
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 August 2023
Resolved 10 July 2023
Resolution: Received objective evidence via photos that lagging was found and re-installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 July 2023 Resolved
A 40–B portable fire extinguisher must be located near the storage room or cabinet. This is in addition to the portable fire extinguishers required by tables 142.230(a) and 142.230(b) of this part. No 40-B portable extinguisher was in the vicinity of the flammable storage locker. 46 CFR 142.225(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 August 2023
Resolved 10 July 2023
Resolution: Received objective evidence an approved portable fire extinguisher (80:BC) was installed in the vicinity of the flammable storage locker.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 5 July 2023 Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. Two of the four engine room ventilation openings had no means to close them off. 46 CFR 144.605
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 August 2023
Resolved 10 July 2023
Resolution: Received objective evidence that plate closures were made for the ventilation openings.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 July 2023 Resolved
At least two lifebuoys on a towing vessel greater than 26 feet must be fitted with a floating electric water light approved under approval series 161.010 or 161.110. The STBD side floating marker light did not have the correct battery (lithium) installed IAW with manufacturer. 46 CFR 141.360(c)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2023
Resolved 10 July 2023
Resolution: Received objective evidence brand new lithium batteries were installed on the ring buoy light.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 5 July 2023 Resolved
Each immersion suit must have a life jacket light approved under approval series 161.112. Two of the six immersion suits life jacket lights were no longer attached. Crew re-attached in the presence of the CG Marine Inspector. 46 CFR 141.350/46 CFR 199.70(c)(4)
Action required: 10 - Deficiency Rectified
Due 5 July 2023
Resolved 5 July 2023
Resolution: Crew re-attached lights in the presence of the CG Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 5 July 2023 Resolved
A towing vessel whose construction was contracted for prior to January 18, 2000, may use an existing engine room monitoring system. The engine room fire detection system showed a fault on one of the heat detectors in the engine room. Vessel had a third party attend to correct the issue. Faults cleared out and new heat detected was satisfactorily tested in the presence of the attending CG Marine Inspector. 46 CFR 143.330(a)(8)
Action required: 10 - Deficiency Rectified
Due 5 July 2023
Resolved 5 July 2023
Resolution: Third party technician attended vessel and corrected the problem w/ CG MI on board. Heat detector was re-tested satisfactorily and the faults cleared out. Technician's report attached to this activity.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 5 July 2023 Resolved
Each towing vessel operating north of lat. 32 degrees N. or south lat 32 degrees S. must carry the number of immersion suits as prescribed. The COI requires six immersion suits, and the vessel was short one. Company representative brought on another immersion suit in the presence of the attending CG Marine Inspector. 46 CFR 141.350(a)
Action required: 10 - Deficiency Rectified
Due 5 July 2023
Resolved 5 July 2023
Resolution: Company representative brought on another immersion suit in the presence of the attending CG Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 July 2023 Resolved
Each lifejacket must have a lifejacket light approved under approval series 161.012 or 161.112 securely attached to the front shoulder area of the jacket. One lifejacket had dead batteries. Batteries replaced w/ correct type and tested in presence of CG Marine Inspector. 46 CFR 141.340(g)(1)
Action required: 10 - Deficiency Rectified
Due 5 July 2023
Resolved 5 July 2023
Resolution: Batteries replaced w/ correct type and tested in presence of CG Marine Inspector.
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 5 July 2023 Resolved
The officer in charge of a navigational watch must conduct a navigation assessment for the intended route and operations prior to getting underway. The captain was not aware he had to fill out navigation assessments prior to getting underway and file them as part of the vessel records. The Captain and company representative were educated on the requirements for filling out navigation assessments. 46 CFR 140.635(a)
Action required: 10 - Deficiency Rectified
Due 5 July 2023
Resolved 5 July 2023
Resolution: The Captain and company representative were educated on the requirements for filling out navigation assessments.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 5 July 2023 Resolved
Each liferaft must be arranged for float free launching. The arrangement must ensure that the liferaft, when released and inflated, are not dragged under by a sinking vessel. The painted was not connect to the hydrostatic release correct, preventing it from inflating. The painter was fixed in the presence of a CG Marine Inspector. 46 CFR 141.310/46 CFR 199.130(c)(7)
Action required: 10 - Deficiency Rectified
Due 5 July 2023
Resolved 5 July 2023
Resolution: The painter was fixed in the presence of a CG Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 July 2023 Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. (c) The valve must be installed in the fuel piping directly outside of the fuel oil supply tank. The valve must be operable from a safe place outside the space where the valve is installed. All three remote fuel shut off valves were inoperable. Crew cleaned up the shut downs and re-tested satisfactorily in the presence of the CG Marine Inspector. 46 CFR 143.260(b-d)
Action required: 10 - Deficiency Rectified
Due 5 July 2023
Resolved 5 July 2023
Resolution: Crew cleaned up the shut downs and re-tested satisfactorily in the presence of the CG Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 July 2023 Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford protection against hazards to life, property, and the environment. The STBD propeller shaft seal was leaking excessively. Crew tightened packing gland, reducing leak in the presence of a CG Marine Inspector. 46 CFR 140.205(a)
Action required: 10 - Deficiency Rectified
Due 5 July 2023
Resolved 5 July 2023
Resolution: Crew tightened packing gland, reducing leak in the presence of a CG Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 5 July 2023 Resolved
Each escape hatch and emergency exit used as a means of escape must be marked on both sides in clearly legible letters at least 2 inches high "EMERGENCY EXIT, KEEP CLEAR". The emergency escape hatch from the chart room to the deck below is not marked accordingly. 46 CFR 144.160(f)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 August 2023
Resolved 10 July 2023
Resolution: Received objective evidence via photos signs were posted above and below the emergency egress hatch.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 25 May 2023 Resolved
Vessels must be manned in accordance with the Certificate of Inspection. The Certificate of Inspection requires one licensed Master and one licensed mate on voyages over 12 hours. The licensed mate departed the vessel, leaving the vessel without a licensed mate as prescribed on the Certificate of Inspection. Vessel is restricted to 12 hour operation only until a licensed mate is provided by the owner/operator of the vessel. Provide evidence that a licensed mate is onboard to the OCMI prior to operating on voyages over 12 hours.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 August 2023
Resolved 31 May 2023
Resolution: Owner/operator provided vessel with properly licensed mate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 July 2022 Resolved
Valve on cross connect on fuel piping is leaking. Repair IAW 46CFR142.229(a).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 August 2022
Resolved 5 August 2022
Resolution: Recieved video of valve not leaking.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 July 2022 Resolved
Life ring buoy on STBD side has wrong type of battery installed. Repair IAW 46CFR141.360(c)(2).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2022
Resolved 5 August 2022
Resolution: Batteries replaced with appropriate type.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 21 July 2022 Resolved
STBD Side Watertight door leading to engine room is damaged at the bottom portion of knife edge. Conduct repairs to satisfaction of attending Marine Inspector IAW 46CFR144.320(b).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2022
Resolved 18 August 2022
Resolution: recieved picture of knife edge repaired.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 July 2022 Resolved
Upper wheel house searchlight is inoperable. Repair or replace IAW 46CFR140.725(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2022
Resolved 18 August 2022
Resolution: recieved picture of operable searchlight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 30 April 2021 Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space. MI discovered a minor fuel leak on the diesel fuel sensor for the starboard generator. Fuel leak estimated to be less than one drip per minute. 46CFR143.220(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2021
Resolved 30 April 2021
Resolution: Sensor re-sealed and operationally tested with no leaks observed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 30 April 2021 Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. These devices must be suitable for the expected route. MI discovered fractured window in weathertight door located on the main deck into the galley, port side. 46CFR144.320(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2021
Resolved 12 May 2021
Resolution: The operator purchased a replacement in kind window and replaced the window on the weathertight door.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 30 April 2021 Resolved
Pressure vessels over 5 cubic feet in volume and over 15 pounds per square inch maximum allowable working pressure (MAWP) must be equipped with an indicating pressure gauge (in a readily visible location) and with one or more spring-loaded relief valves. The total relieving capacity of such relief valves must prevent pressure from exceeding the MAWP, as established by the manufacturer, by more than 10 percent. MI found the pressure vessels located in the engine room are stamped with a MAWP of 200 psi and fitted with a 250 psi relief valve, exceeding the 10 percent allowable maximum pressure. 46CFR143.300(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2021
Resolved 12 May 2021
Resolution: Pressure relief valves replaced with new relief valves rated for pressure relief at 175 psi.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 April 2021 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Installed electrical power source(s) must be capable of carrying the electrical load of the towing vessel under normal operating conditions. Port and Stbd generator windings found heavily oiled and with dirt/debris. Provide insulation resistance test with a megohmmeter conducted in accordance with manufacturer instructions. Test results must include the resistance measured between each winding and from each winding to ground. Include recommendations on whether windings shall be cleaned, rewound, or if they are within manufacturer insulation resistance specifications. Or replace generators in kind if desired. 46CFR 143.400(a)(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2021
Resolved 28 July 2021
Resolution: The operator replaced both of the ship's service generators in kind. Data sheets for the generators and motors are attached in documents.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 30 April 2021 Resolved
Immersion suits carried on towing vessels must meet the requirements of 199.70(c) and (d) of this chapter. MI found all six (6) immersion suits with expired lights. 46CFR141.350(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 May 2021
Resolved 12 May 2021
Resolution: The immersion suit lights were replaced with CG 199.70(c) approved lights.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 30 April 2021 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. MI identified two extension cords daisy chained together with two multi outlet surge protectors at the main operating station. The breaker for the use of this was incorrectly identified on the breaker panel. The 110 V conductor for this installation was found jumped at the double pole breaker identified for the 220V outlet in the pilot house. MI identified dust and dirt in the breaker panel when disassembled by the crew. The crew cleaned the breaker panel box and removed the 110 V conductor from the 220 V double pole breaker. 46CFR143.400(a)
Action required: 10 - Deficiency Rectified
Due 30 April 2021
Resolved 30 April 2021
Resolution: The operator disconnected the 110V conductor and added a 15 amp single pole breaker to the distribution panel. The 110 V conductor connected to an electrical outlet is now connected to the 15 amp breaker. All daisy chains removed.
Lifesaving › Visual Distress Signals (General) › Not on Board
Issued 18 August 2006 Resolved
Vessel master could not show proof of any visual distress signals.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 January 2013
Resolution: Vessel is not required visual distress signals onboard due to route.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Pressure
Issued 18 August 2006 Resolved
Vessel needs more pressure in the fire system. During the inspection hoses could be squeezed by the hand.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 January 2013
Resolution: Vessel''s fire pump was able to produce sufficeint pressure at nozzles.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 18 August 2006 Resolved
Vessels life jackets and ring life buoys need to have the vessels name stenciled on both sides.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 January 2013
Resolution: Vessels name was stenciled on life buoys and life jackets.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 18 August 2006 Resolved
Vessel's EPIRB requires service.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 January 2013
Resolution: Vessel EPIRB was removed, not required for route of service.
Lifesaving
Issued 29 October 1996 Resolved
ALL OF THE VESSELS LIFEJACKETS WERE MISSING WHISTLES. THE CAPTAIN WAS GOINGTO GET SOME FROM THE OIL RIG WHEN THE VESSEL ARRIVES OFFSHORE.
Condition: Unknown
Due 5 November 1996
Resolved 3 February 1997
Fire Fighting
Issued 29 October 1996 Resolved
VESSEL WAS MISSING METAL INSPECTION TAGS ON ALL FIRE EXTINGUISHERS. THERE WAS NO DOCUMENTATION OF INSPECTIONS ONBOARD.
Condition: Unknown
Due 29 November 1996
Resolved 3 February 1997
Documentation
Issued 29 October 1996 Resolved
COULD NOT READ TANKERMANS LICENSE. PICTURE HAD BEEN TAPED IN PLACE AND INFORMATION ON CARD HAD BEEN WRITTEN OVER WITH AN INK PEN.
Condition: Unknown
Due 12 November 1996
Resolved 3 February 1997
Navigation
Issued 29 October 1996 Resolved
ALL NAVIGATIONAL LIGHTS ONBOARD HAD HOUSEHOLD BULBS INSTALLED.
Condition: Unknown
Due 29 November 1996
Resolved 3 February 1997
Engineering
Issued 16 December 1986 Resolved
VESSEL DID NOT HAVE A STANDARD DISCHARGE CONNECTION ON BOARD AS REQUIRED BY33CFR155.410(A)(3). VESSEL WAS CITED FOR THIS SAME VIOLATION 10JUN86; REF: PS86049041. COMPLIANCE DATE WAS 06JUL86, STILL NOT CORRECTED. LETTER DTD 02SEP86 FM OWNER STATED THIS ITEM CORRECTED, HOWEVER STILL PENDING TO DATE.
Condition: Unknown
Due 16 December 1986
Resolved 16 December 1986
Engineering
Issued 10 June 1986 Resolved
VESSEL DID NOT HAVE INSTALLED PIPING TO DISCHARGE OILY WASTE TO A RECEPTIONFACILITY AS REQUIRED BY 33CFR155.410(A)(1).
Condition: Unknown
Due 10 June 1986
Resolved 10 June 1986
Engineering
Issued 10 June 1986 Resolved
VESSEL DID NOT HAVE A STANDARD DISCHARGE CONNECTION ON BOARD AS REQUIRED BY33CFR155.410(A)(3).
Condition: Unknown
Due 10 June 1986
Resolved 10 June 1986

Recorded names · 1

TIM V. SETTOON (2014). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.