Records from 1994 to 2025. Most recent: inspection, 10 October 2025.
Inspection history · 26
10 October 2025
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8250425
30 July 2025
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8198874
15 January 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8064478
8 August 2024
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7977174
19 July 2024
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7960380
21 May 2024
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7888141
7 September 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7786343
3 May 2022
Initial Certification · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7442151
29 October 2021
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7341920
17 September 2013
Administration
Administrative · USCG East District (dp) · USCG East District (CGD-E) · Activity 4716839
12 August 2013
Administration
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 4682606
29 April 2008
DAPI Audit
Administrative · USCG East District (dp) · USCG East District (CGD-E) · Activity 3195248
11 October 2007
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3078476
1 December 2006
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2833664
11 August 2005
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2464174
1 May 2005
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2347182
7 October 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2216602
30 September 2003
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1917607
20 November 2001
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 115351
1 August 2001
Uninspected Towing Vessel
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1075043
2 March 1999
Uninspected Towing Vessel
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 799041
13 November 1998
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 43929
7 February 1997
Uninspected Towing Vessel
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1106112
16 October 1996
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1097870
3 January 1996
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 37606
12 October 1994
Type not recorded
No type recorded · District 5 (B) · USCG East District (CGD-E) · Activity 660834
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 July 2024
Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. Vessel has installed an air conditioner unit from the engine room to the galley.
Condition: Design Flaw
Action required: 60 - Rectify deficiencies prior to movement
Due 19 July 2024
Resolved 23 July 2024
Resolution: Vsl removed AC unit and welded a steal plate in its place. See photo attached to def.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 19 July 2024
Resolved
46 CFR 144.405: Each vessel must be designed and constructed to minimize fire hazards insofar as reasonable and practicable. Vessel has wiring routed through vent/air duct system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2024
Resolved 23 July 2024
Resolution: Wires removed.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 19 July 2024
Resolved
46 CFR 144.830: Each exhaust pipe from an internal combustion engine which is within reach of personnel must be insulated or otherwise guarded to prevent burns. STBD engine exhaust has an exposed section of exhaust pipe
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2024
Resolved 7 August 2024
Resolution: Insulation instatalled over exposed STBD exhaust piping. Def cleared.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 19 July 2024
Resolved
46 CFR 144.320: Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. These devices must be suitable for the expected route. The head on the 02 deck STBD side head has a broken window.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2024
Resolved 23 July 2024
Resolution: Window glass replaced.
10 - Safety of Navigation › N/A - No Subsystem › Navigation records
Issued 19 July 2024
Resolved
46 CFR 140.635: The officer in charge of a navigational watch must conduct a navigation assessment for the intended route and operations prior to getting underway... At a minimum, this assessment must consider...Vessel navigation assessment only indicates completion of navigation assessment, it does not log the status of the minimum required considerations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2024
Resolved 16 August 2024
Resolution: Proof of nav assessment sent in. Recent assessments attached to documents.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 19 July 2024
Resolved
46 CFR 141.245(b): Inspections and tests of lifesaving equipment must be recorded in the TVR, official logbook, or in accordance with any TSMS applicable to the vessel. The following minimum information is required….The dates when inspections and tests were performed, the number or other identification of each unit inspected and tested, the results of the inspections and tests, and the name of the crewmember, surveyor or auditor and any others conducting the inspections and tests; and….Receipts and other records documenting these inspections and tests must be retained for at least 1 year after the expiration of the COI and made available upon request.
Vessel logs do not contain inspections and tests of vessel lifesaving equipment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2024
Resolved 7 August 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 July 2024
Resolved
46CFR 143.245: Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. The tests required by this section must be recorded in accordance with part 140 of this subchapter. Vessel does not have record of pressure vessel relief valve test
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2024
Resolved 7 August 2024
Resolution: Test completed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 19 July 2024
Resolved
46CFR 141.360(b): Each lifebuoy on a towing vessel must…Be approved under approval series 160.050 or 160.150;
03 life rings were observed to have unsatisfactory retro-reflective material.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2024
Resolved 23 July 2024
Resolution: New retro tape affixed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 September 2023
Resolved
Electrical components that pose an electrical hazard must be in an enclosure. MI observed exposed dead end wires underneath wheelhouse console.
46 CFR 143.400(g)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2023
Resolved 8 September 2023
Resolution: Capped off dead end wires.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 September 2023
Resolved
All fire hoses must be inspected for excessive wear, and subjected to a test pressure equivalent to the maximum service pressure. All fire hoses which are defective and incapable of repair must be destroyed. MI observed 01 Fire Hose with a pin-hole in it.
46 CFR 143.240(a)(7)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2023
Resolved 8 September 2023
Resolution: Purchased new fire hose.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 7 September 2023
Resolved
Each life raft must be arranged to permit it to drop into the water from the deck on which it is stowed. MI observed a life raft that could not easily be dropped into the water from the deck in which it was stowed. Provide means to meet the regulations at next dry dock.
46 CFR 199.130(c)(3)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2025
Resolved 31 July 2025
Resolution: Liferaft stowed correctly
10 - Safety of Navigation › N/A - No Subsystem › Navigation records
Issued 7 September 2023
Resolved
The officer in charge of a navigational watch must conduct a navigation assessment for the intended route and operation prior to getting underway. Vessels current pre-underway checklist did not include the required items as described in 46CFR140.635.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2023
Resolved 8 September 2023
Resolution: Provided new list for nav assessment.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 May 2022
Resolved
Each towing vessel must have a fire-detection system installed to detect engine room fires. The owner or managing operator must ensure the system is arranged and installed so a fire in the engine room automatically sets off alarms on a fire detection control panel at the operating station; fire detection panel showing faults and unable to reset; repair/replace to the satisfaction of the OCMI.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2022
Resolved 12 May 2022
Resolution: Observed crew test the heat sensor in engine room and confirmed the fire detection control panel operated properly and was able to clear any faults.
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 3 May 2022
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided: auxiliary generator engine high cooling water temperature; stbd audible/visual alarms at the operating station inop; repair/replace to the satisfaction of the OCMI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2022
Resolved 11 May 2022
Resolution: High water cooling water temperature was installed on auxiliary generator engine. STBD Visual and audible alarms are working properly.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 3 May 2022
Resolved
All pressure vessels must have their MAWP indicated by stamp, name plate, or other means visible to the crew; MAWP not demonstrated on pressure vessel in the machinery space; repair to satisfaction of OCMI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2022
Resolved 11 May 2022
Resolution: Data plate was found painted over on the pressure vessel in machinery space, paint was removed and MIs were able to verify the MAWP.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 May 2022
Resolved
A 40-B portable fire extinguisher must be located near the storage room or cabinet housing flammable or combustible products; fire extinguisher not present.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2022
Resolved 11 May 2022
Resolution: O/O installed new A-60 B:C fire extinguisher on top deck.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 3 May 2022
Resolved
The master or officer in charge of the watch must ensure all hatches, doors, and other openings designed to be watertight or weathertight function properly; portlight missing dead cover and glass is broken; repair/replace to the satisfaction of the OCMI.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2022
Resolved 12 May 2022
Resolution: Observed new hatch cover installed over port light in galley space.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 24 April 2008
Resolved
EAP Requirements- Training is required for Supervisory positions on the Vessel. Supervisor receive 1 hour EAP training needed
Due 14 May 2008
Resolved 12 May 2008
Resolution: [name withheld], Vulcan’s, Manager, Safety Health and Environmental submitted necessary documentation with plan of action for future program management.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 24 April 2008
Resolved
Record keeping- Company did not do DOT required background check in the past on new employees, representative DER at the audit was under the impression that having new employees take a pre-employment drug test fulfilled the requirements. Was told by DAPI that all employees need to have a background check done who were there latest hires.
Due 14 May 2008
Resolved 12 May 2008
Resolution: [name withheld], Vulcan’s, Manager, Safety Health and Environmental submitted necessary documentation with plan of action for future program management.
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 24 April 2008
Resolved
Company did not show proof of Alcohol Testing Kits. DER and Safety person showed a sample of a drug
Testing kit that would be used for a serious marine incident testing, not incompliance with the applicable regulations.
Due 14 May 2008
Resolved 12 May 2008
Resolution: [name withheld], Vulcan’s, Manager, Safety Health and Environmental submitted necessary documentation with plan of action for future program management.