Records from 2003 to 2025. Most recent: inspection, 16 May 2025.
Documentation record
Registered dimensions (L × B × D)82.8 ft × 33.0 ft × 13.0 ft
Registered tonnagegross 147 / net 100
ITC dimensions (L × B × D)82.8 ft × 33.0 ft × 13.0 ft
ITC tonnagegross 265 / net 79
BuilderNORTHAMERICAN SHIPBLDG · LAROSE, LA, UNITED STATES · built 1994
Hull materialSteel
PropulsionDiesel
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGALLIANO, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 23 July 2026 · expires 31 August 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it147 - Regulatory (Subpart C or D), Gross Ton
265 - Convention (Subpart B), Gross Ton
100 - Regulatory (Subpart C or D), Net Ton
79 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 18
16 May 2025
Administrative Inspection · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8137475
14 January 2025
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8063367
17 July 2024
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7959726
19 March 2024
Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7882415
28 September 2023
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7800876
28 August 2023
Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7778866
13 July 2023
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7741895
28 September 2022
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7568019
26 July 2022
Administrative Inspection · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7517253
8 September 2021
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7307310
28 January 2021
Administrative Inspection · Special Consideration
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7132441
26 June 2020
Deficiency Check · Initial Certification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6987736
16 December 2010
MTSA Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3911951
22 April 2010
Industry Initiated Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3725697
21 May 2007
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2993895
27 September 2006
Deficiency Check · MTSA Verification · Uninspected Other
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2800157
11 July 2005
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2422818
25 June 2003
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1826809
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 July 2024
Resolved
Vessel fire pump remote start is in the same space as the fire pump. As per 46 CFR 142.325(a)(2) the remote start must be outside the space. Move remote start to a location outside the space no later than the vessels next dry-dock.
Action required: 705 - Other - as specified
Resolved 7 August 2024
Resolution: Received photo of remote start moved outside of space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 March 2024
Resolved
Vessel had a steering casualty. Make vessel available for inspection while hauled out at March 2024 dry docking. Identify cause of casualty and propose a repair plan if repairs are required.
Cite: 46 CFR 137.300(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 March 2024
Resolution: Received final tech report from company stating repairs were completed and tested. ALL SAT.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 28 August 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide tor safe operation of the towing vessel. Vessel POC reported issues with steering system. Submit repair proposal and repair steering with CG oversight.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2023
Resolution: Re-built Z drive, installed and performed sea trials.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 26 June 2020
Resolved
E lighting in ladder well from Navigation deck did not energize upon loss of ships power. Ensure all E lighting energizes when required.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 August 2020
Resolution: VERIFIED
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 26 June 2020
Resolved
Repair fire pump mechanical seal.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 August 2020
Resolution: Pump replaced
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 June 2020
Resolved
Properly wire all Raycor filter dirty fuel alarms, ensure connections are made inside of an enclosure.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 August 2020
Resolution: verified proper wiring
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 June 2020
Resolved
Replace all plastic waste bins with non combustible types.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 August 2020
Resolution: replaced with metal
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 26 June 2020
Resolved
Propulsion machinery and systems must be maintained to ensure proper operation. Repair forward operating station stbd thruster angle indicator to provide proper angle of thruster.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 August 2020
Resolution: Verified operational
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 26 June 2020
Resolved
VHF radios must be installed at each operating station and connected to a functioning batter back up. Properly connect aft operating station VHF radio to battery back-up.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 August 2020
Resolution: audit conducted
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 26 June 2020
Resolved
Provide vessel oil transfer procedures for bunkering and internal transfers.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 August 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 June 2020
Resolved
Machinery systems must be designed and maintained to provide for safe operation of the towing vessel. Return fuel line on the port main diesel engine is worn due to chafing on the nearby deck plate.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 August 2020
Resolution: chafing installed