Records from 1994 to 2025. Most recent: inspection, 20 August 2025.
Documentation record
Registered dimensions (L × B × D)82.8 ft × 33.0 ft × 13.0 ft
Registered tonnagegross 147 / net 100
ITC dimensions (L × B × D)82.8 ft × 33.0 ft × 13.0 ft
ITC tonnagegross 265 / net 79
BuilderNORTH AMERICAN SHIP BUILD · LAROSE, LA, UNITED STATES · built 1994
Hull materialSteel
PropulsionDiesel
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGALLIANO, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 22 July 2026 · expires 31 August 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it265 - Convention (Subpart B), Gross Ton
147 - Regulatory (Subpart C or D), Gross Ton
79 - Convention (Subpart B), Net Ton
100 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 23
20 August 2025
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8214630
16 May 2025
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8137428
14 January 2025
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8063400
15 August 2024
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7982107
25 July 2024
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7966611
28 August 2023
Annual Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7778816
13 July 2023
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7741877
16 September 2022
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7560617
3 August 2022
Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7523897
8 September 2021
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7307307
28 January 2021
Special Consideration · Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7132430
10 June 2020
Initial Certification · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6987676
11 December 2013
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4824310
16 December 2010
MTSA Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3911921
10 June 2010
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3762845
6 May 2010
Industry Initiated Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3735895
21 May 2007
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2993895
18 October 2006
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3077148
11 October 2006
Uninspected Other · MTSA Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2800061
11 July 2005
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2422796
6 August 1997
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 93553
6 August 1997
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 179908
26 July 1994
Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 868726
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 July 2024
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid. MI found a fitting on the starboard Z-Drive unit that was weeping hydraulic oil. Fix leak at upcoming dry-dock scheduled for August 13, 2024 as discussed.
46 CFR 143.220
50 - Rectify deficiencies w/in 30 days
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2024
Resolved 1 August 2024
Resolution: Received video and photos that the starboard steering leak had be fixed. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 August 2023
Resolved
The crew of each towing vessel must demonstrate the ability to operate the primary and auxiliary machinery and electrical systems for which they are responsible, and to do so under normal and emergency conditions. This includes, but is not limited to, responses to alarms and restoration of propulsion and steering in the event of failure. Crew needs to demonstrate proper operation of the bilge pump and system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2023
Resolved 31 August 2023
Resolution: Witness satisfactory bilge pump test
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 September 2022
Resolved
A towing vessel subject to this subchapter and choosing the Coast Guard inspection option, or required to have the Coast Guard inspection option, must undergo an annual inspection within 3 months before or after the COI anniversary date. Vessel failed to obtain an annual inspection within the alloted time frame.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 September 2022
Resolution: Vessel completed annual inspection
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 June 2020
Resolved
Each towing vessel must be equipped with Navigation lights IAW COLREGs or 33 CFR 84 as appropriate for its area of operations. Vessel has 01 inoperable yellow light. Repair IAW Rule 24, pushing ahead/alongside.
Prior to night operations or reduced visibility.
Action required: 705 - Other - as specified
Resolved 23 June 2020
Resolution: Received pictures of lights on.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 June 2020
Resolved
Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve. Correctly label all breakers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2020
Resolved 23 June 2020
Resolution: Pictures received of all 4 panel markings.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 10 June 2020
Resolved
A record of the type, size and service of towline and spring line used must be available to CG for review. Provide records of towing lines for review and maintain in Towing Vessel Records. Ensure future examinations meet minimum requirements.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2020
Resolved 23 June 2020
Resolution: Received statement from Master that towline inspection form is updated in HELM system to be updated weekly.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 June 2020
Resolved
Flammable or combustible products must be in a designated room free of ignition sources or dedicated flammable locker. Remove flammable products from machinery spaces.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2020
Resolved 23 June 2020
Resolution: Received statement from Master that all flammable/combustible stores removed from vessel and placed in shoreside flammable locker.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 June 2020
Resolved
Electrical connections must be suitably installed. Properly install cable on winch motor in Mach Shop.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2020
Resolved 23 June 2020
Resolution: Received pictures.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 June 2020
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid into the machinery space. Fuel filters are leaking from pet cock. Make filters leak free.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2020
Resolved 23 June 2020
Resolution: Pictures of new petcock installed.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 June 2020
Resolved
Port side waste oil line is wrapped in oil soaked rags with bucket full of oil tied off to the line. Make line leak free and remove oil soaked rags and bucket of oil. Steering Transfer Hydraulic Oil on starboard side in engine room has temporary epoxy repair. Properly repair.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2020
Resolved 23 June 2020
Resolution: Received picture of new 45* elbow installed.