Inspection history · 20
28 January 2026
Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8296925
24 April 2025
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8118336
29 January 2025
Deficiency Check · COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8069079
1 August 2024
Drydock Exam · In-Service Inspection · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7973064
25 July 2022
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7516232
18 July 2022
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7510501
18 July 2022
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7511248
31 January 2022
Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7388546
1 May 2020
Administrative Inspection · Initial Certification
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6948125
21 February 2020
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6913016
2 May 2017
Industry Initiated Exam
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6137470
18 September 2014
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4989412
25 January 2012
Industry Initiated Exam · DAPI Audit
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4232450
1 January 2012
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4219668
17 February 2010
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3681296
9 January 2010
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3663135
17 February 2000
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 75266
13 January 2000
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 148480
24 May 1999
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 429105
20 March 1999
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 426760
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 January 2026
Resolved
All portable fire extinguishers, semi-portable fire extinguishing systems, fire-detection systems… must be inspected or tested at least once every 12 months…
There was no evidence onboard that the fire detection system had been inspected within the past 12 months.
Hourly rounds must be conducted while the vessel is operating to check for fire until the fire detection system is inspected by an approved fire inspection agency.
46 CFR 142.240(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2026
Resolved 25 February 2026
Resolution: Fire detection system inspected and certified.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 28 January 2026
Resolved
Towing vessels must be equipped with the following equipment…Illuminated magnetic compass or an illuminated swing-meter (Western Rivers vessels only). The compass or swing-meter must be readable from each operating station.
Compass not installed at operating station.
46 CFR 140.725 (d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2026
Resolved 25 February 2026
Resolution: Compass was installed and the Captian told me that he swung it as well.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 January 2026
Resolved
Each lifejacket must have a lifejacket light approved under approval series 161.012 or 161.112 securely attached to the front shoulder area of the lifejacket.
The lights on all the lifejackets were expired.
46 CFR 141.340 (g)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2026
Resolved 25 February 2026
Resolution: New, approved PFD lights installed on all life jackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 January 2026
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel…
Coolant was leaking from the starboard aft coolant expansion tank located above the starboard main diesel engine.
46 CFR 143.205 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2026
Resolved 25 February 2026
Resolution: The leak was fixed, it was a loose pipe fitting.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 January 2026
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions.
Portable, non-marine-grade space heaters and a power strip were in the pilothouse. Remove these items.
46 CFR 143.205 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2026
Resolved 25 February 2026
Resolution: Power strips and space heaters were removed.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 28 January 2026
Resolved
Means must be provided…for closing, in case of fire, each doorway, ventilator, and annular space around funnels…
The closures on the outside of the funnels were not airtight when closed.
46 CFR 144.610
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2026
Resolved 25 February 2026
Resolution: Gasket material was applied to make the dampers more airtight.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 28 January 2026
Resolved
The emergency duties and duty stations…must be posted at each operating station and in a conspicuous location in a space commonly visited by crewmembers.
The muster list was not posted in the pilothouse.
46 CFR 140.405 (c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2026
Resolved 25 February 2026
Resolution: A muster list was posted in the Pilothouse.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 28 January 2026
Resolved
Sufficient lighting suitable for the marine environment must be provided within crew working and living areas.
Multiple light fixtures were missing their protective covers in the engine room.
46 CFR 143.410 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2026
Resolved 25 February 2026
Resolution: Covers were replaced on lights.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 29 January 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons. Exhaust leak on port main.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2025
Resolved 11 February 2025
Resolution: Witnessed no exhaust leak.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 August 2024
Resolved
Regardless of the option chosen to obtain a COI, upon obtaining a COI each towing vessel must then undergo a dry dock and internal structural examination...
A. In forward rake, replace all vertical truss frames that are bent.
B. In starboard side forward rake, weld upper transverse frames 1, 2, and 3, that are not welded to deck.
C. In center fuel tank on the port aft side, crop and renew inset.
D. In port and starboard fuel tanks on the outboard aft section on bilge turn, grind and re-weld insets.
E. In starboard aft lazarette, re-weld two gussets.
F. In port aft lazarette, replace stuffing tube packing.
G. Install shut off valve on all through hull keel cooler penetrations.
H. Fire main sea suction, remove overhead drain piping and cap to prevent water intrusion.
I. Replace all pressure regulator valves on air compressor.
J. Signs of exhaust leak on port and starboard generators. Repair to satisfaction of marine inspectors.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2025
Resolved 29 January 2025
Resolution: Completed all repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 25 July 2022
Resolved
Steering system required to be maintained and operational. Steering system inoperable. Determine cause of failure and provide repair proposal to Coast Guard. complete approved repairs prior to towing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 July 2022
Resolution: Inspected and tested steering system, sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 July 2022
Resolved
Steering system required to be maintained and operational. Steering system inoperable. Determine cause of failure and provide repair propossal to Coast Guard. complete approved repairs prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 July 2022
Resolution: Inspected new hydraulic hose installation, sat. Operationally tested steering system, sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 31 January 2022
Resolved
Vessel has not received annual inspection as required for the Coast Guard option.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 April 2022
Resolution: Completed inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 30 July 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Port gen was not working. Repair and test for proper operation as per 46cfr143.400
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 30 July 2020
Resolved 31 July 2020
Resolution: Received call that gen was back on line and working, fuel filters were changed out.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 July 2020
Resolved
A towing vessel must carry lifebuoys and be marked in block capital letters with the name of the vessel. The name of vessel is fading on lifebuoys. Correct as needed per 46cfr141.360(4)(b)(4)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2020
Resolved 15 April 2022
Resolution: Completed from earlier event.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 30 July 2020
Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. The door on STBD side had a cracked window. Repair as needed per 46cfr144.320
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2020
Resolved 15 April 2022
Resolution: Completed from earlier event.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 30 July 2020
Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. These devices must be suitable for the expected route. Port door to engine room not working properly. Repair as needed and per 46cfr144.320 (b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2020
Resolved 15 April 2022
Resolution: Completed from earlier event.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 July 2020
Resolved
Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve. Label missing or faded on some electrical panel breakers. Label each breaker with correct description. As per 46cfr143.400(d)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2020
Resolved 30 July 2020
Resolution: Labeling was corrected.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 30 July 2020
Resolved
Each device must have a placard suitable for posting on which is printed the operating instructions, safety precautions, and warnings pertinent to the device. The size of the letters printed on the placard must be one-eighth of an inch or larger. MSD was missing this placard, add per 33cfr159.59
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2020
Resolved 15 April 2022
Resolution: Completed from earlier event.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 July 2020
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards. Exhaust fans in engine room are dirty with black soot, clean as necessary. Per 46cfr142.220
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2020
Resolved 15 April 2022
Resolution: Completed from earlier event.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 30 July 2020
Resolved
Vessel is missing hailing port on stern. Label hailing port on stern as per 46cfr67.123.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2020
Resolved 15 April 2022
Resolution: Completed from earlier event.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 30 July 2020
Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. Shut off is located in engine room and not easy to shut off during engine room fire. Install a emergency shut off for ventalation fans to eliminate possible injury to person in event of fire. Per 46cfr140.510
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2020
Resolved 15 April 2022
Resolution: Completed from earlier event.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 30 July 2020
Resolved
Fire detection system did not have PE letter on board. Vessel missing PE letter. Owner/operator locate and provide approval PE letter for installed fire detection panel. Per 46cfr142.330(a)(1)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2020
Resolved 30 July 2020
Resolution: PE leter found and placed on boat.
Fire Fighting
Issued 20 March 1999
Resolved
PORTABLE FIRE EXTINGUISHER REQUIRED IN MACHINERY SPACE: ONE TYPE B-II SHALLBE CARRIED FOR EACH 1000 B. H. P. OF THE MAIN ENGINE. NEED AT LEAST ONE B- II PLACED IN THE ENGINE ROOM FOR 1200 B. H. P. ON THE MAVRICK.
Condition: Unknown
Due 22 March 1999
Resolved 22 March 1999
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 20 March 1999
Resolved
TWO ELECTRICAL BOXES LOCATED IN THE ENGINE ROOM ARE MISSING THE DOORS THAT COVER THE FUZE SWITCHES. JUST NEED TO ADD THE COVERS TO THE BOXES. THIS ISA CAPTAIN OF THE PORT (COTP) REQUIREMENT.
Condition: Unknown
Due 20 April 1999
Resolved 9 February 2006
Documentation › Markings/Placards › Warning Signs
Issued 20 March 1999
Resolved
POST A PLACARD WITH OPERATING INSTRUCTIONS, SAFETY PRECAUTIONS, AND WARNINGS PERTINTENT TO THE DEVICE. (FOUND IN 33 C.F.R. 159.59)
Condition: Unknown
Due 20 April 1999
Resolved 9 February 2006