Inspection history · 106
28 January 2026
Deficiency Check · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8302591
17 October 2025
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8253668
30 July 2024
Periodic Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7966087
13 June 2024
Examination of Repairs · Deficiency Check · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7934499
28 April 2024
Explosive Handling Operation-Military
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7904082
27 April 2024
Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7907685
18 February 2024
Explosive Handling Operation-Military
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7868885
17 February 2024
Explosive Handling Operation-Military
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7866388
10 October 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7806410
1 October 2023
Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7807755
30 September 2023
Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7798378
9 July 2023
Explosive Handling Operation-Military
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7742030
8 July 2023
Explosive Handling Operation-Military
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7736831
29 April 2023
Explosive Handling Operation-Military
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7678020
3 October 2022
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7569635
24 April 2022
Explosive Handling Operation-Military
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7438651
23 April 2022
Explosive Handling Operation-Military
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7438019
27 February 2022
Explosive Handling Operation-Military
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7406035
26 February 2022
Explosive Handling Operation-Military
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7403520
1 September 2021
Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7300435
25 June 2021
Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7271714
9 May 2021
Explosive Handling Operation-Military
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7195625
11 October 2020
Explosive Handling Operation-Military
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7085419
10 October 2020
Explosive Handling Operation-Military
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7085436
4 October 2020
Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7073407
3 October 2020
Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7072677
13 September 2020
Explosive Handling Operation-Military
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7064520
12 September 2020
Explosive Handling Operation-Military
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7064509
15 July 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7007165
11 July 2020
Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7005791
19 July 2019
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6761112
18 June 2019
Drydock Exam · Periodic Inspection · Administrative Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6714215
25 September 2018
Administrative Inspection · MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6515289
10 October 2017
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6284657
22 September 2017
Administrative Inspection · Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6271793
15 August 2016
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5973769
19 July 2016
Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5946338
29 June 2016
Administrative Inspection · Deadweight Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5947670
17 June 2016
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5910748
10 June 2016
Internal Structural Exam · Drydock Extension · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5902883
11 May 2016
Drydock Extension
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5874838
1 December 2015
Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5773473
22 November 2015
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5773441
21 November 2015
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5774965
2 November 2015
Administrative Inspection · Examination of Repairs · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5756786
17 October 2015
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5753070
16 October 2015
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5747047
11 October 2015
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5742119
10 October 2015
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5741446
2 October 2015
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5753990
28 October 2014
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5027294
27 October 2014
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5013228
25 October 2014
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5013203
23 October 2014
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5010948
14 September 2014
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4984338
13 September 2014
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4984349
6 August 2014
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4978068
17 July 2014
Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4925608
23 June 2014
Internal Structural Exam · Periodic Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4885320
3 June 2014
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4878958
27 May 2014
Spot Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4871588
27 May 2014
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4878563
3 September 2013
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4704649
26 August 2013
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4714379
9 August 2013
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4687243
23 July 2013
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4677826
14 November 2012
Examination of Repairs · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4483421
24 July 2012
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4385231
2 August 2011
Internal Structural Exam · Administrative Inspection · Hull Examination · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4103062
8 July 2011
COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4074260
7 September 2010
Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3844671
31 August 2010
Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3838803
24 May 2010
Administrative Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3746654
28 September 2009
Periodic Inspection · MTSA Verification
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3604717
10 February 2009
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3415332
28 July 2008
Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3282174
17 June 2008
MTSA Verification · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3240780
28 May 2008
Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3220532
31 May 2007
Annual Inspection · MTSA Verification
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2975950
31 August 2006
COI Inspection · MTSA Verification
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2765144
17 February 2006
Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2602421
12 May 2005
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2356221
2 May 2005
Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2347448
7 September 2004
MTSA Verification · Internal Structural Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2185754
2 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1957675
30 September 2003
Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1917627
16 September 2003
Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1907265
27 January 2003
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1743859
24 October 2002
Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1694360
25 March 2002
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1650533
20 November 2001
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1076161
28 September 2001
COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1370426
19 September 2000
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1054112
5 September 2000
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1393519
27 March 2000
Excursion Permit
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1047700
20 January 2000
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 815154
18 November 1999
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 812489
17 October 1999
Hull Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1361198
23 March 1999
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 776518
29 October 1998
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 805055
22 September 1998
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1454606
20 May 1998
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 67561
12 November 1997
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1372034
28 July 1997
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 59036
30 October 1996
Initial Construction-Excluding Oversight · Initial Certification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1380971
10 October 1996
Deadweight Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1161407
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 17 October 2025
Resolved
The means for securing and maintaining weathertightness shall be to the satisfaction of the assigning authority. The arrangements shall ensure that the tightness can be maintained in any sea conditions. The pump room quick acting water tight hatch gasket securing arrangement is corroded/wasted. Repair or replace the quick acting water tight hatch gasket securing arrangement in accordance with the original equipment manufactures instructions to the satisfaction of the attending USCG Marine Inspector. 46 CFR 42.15-30 (c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 December 2025
Resolved 30 January 2026
Resolution: Pump room quick acting watertight hatch was replaced, all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 10 October 2023
Resolved
It shall be the responsibility of the master to assure himself that all exposed cargo hatches and other openings in the hull of his vessel are closed, made properly watertight by the use of tarpaulins, gaskets or similar devices, and in all respects properly secured for sea before leaving protected waters. 02 hatch covers for the fore rake were deteriorated, as well as 01 hatch cover on the port side. Install new gaskets on the hatch covers.
46 CFR 97.15-20(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2023
Resolved 11 October 2023
Resolution: Received photos from operator with replaced gaskets. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 June 2021
Resolved
At each inspection for certification, periodic inspection and at other times necessary, the inspector will determine that all fire-extinguishing equipment is in suitable condition and may require any tests necessary to determine the condition of the equipment. Generator flat portable fire extinguisher bracket wasted. Replace with approved bracket.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2021
Resolved 17 August 2021
Resolution: Port engineer provided photgraph of the new approved bracket installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 June 2021
Resolved
Shutoff valves. Shutoff valves shall be installed in the fuel supply lines, one as close to each tank as practicable. Shutoff valve installed so as to close against the fuel flow fitted in the fuel supply line at the engine failed to stop fuel flow by not completely closing. Adjust valve and prove proper operation to the satisfaction of the attending MI.
Action required: 10 - Deficiency Rectified
Due 4 August 2021
Resolved 4 August 2021
Resolution: On site CAT techs drilled another cable locating hole in valve handle for more leverage. Valve operation and closing was satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 15 July 2020
Resolved
The means for securing and maintaining weathertightness shall be to the satisfaction of the assigning authority. Hatch cover for 1S Ballast Tank is missing one dog.
46 CFR 42.15-30(c)(1)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 22 July 2020
Resolution: Vessel rep submitted photographic evidence of replacement of missing dog.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 18 June 2019
Resolved
No repairs or alterations affecting the safety of the
vessel with regard to the hull, machinery, or equipment,
shall be made without the knowledge of the Officer in
Charge, Marine Inspection. Submit repair proposal to
address No. 3-6 tripped vertical stiffeners in the port
stern rake.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2019
Resolution: Approved repair proposal, witnessed fit-up, back gouge, and final of repairs to 4 vertical stiffeners in the port stern rake, all sat.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 18 June 2019
Resolved
No repairs or alterations affecting the safety of the
vessel with regard to the hull, machinery, or equipment,
shall be made without the knowledge of the Officer in
Charge, Marine Inspection. Submit repair proposal to
address wasted triangular bracket in way of connection
of the main deck, aft transverse bulkhead, and the No. 1
underdeck longitudinal counting inboard from starboard
sideshell, found in the starboard forward ballast tank.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2019
Resolution: Verified repairs were made IAW approved repair proposal, all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 18 June 2019
Resolved
All exposed openings in the hull shall be made properly
watertight by the use of gaskets or similar devices, and
in all respects properly secured for sea before leaving
protected waters. Renew gasket on hatch covers to both
port forward and port aft ballast tanks.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2019
Resolution: Verified new gaskets were installed on the hatch covers to port forward and port aft ballast tanks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 June 2019
Resolved
Shutoff valves shall be installed in the fuel supply
lines, one as close to each tank as practicable, and one
as close to each fuel pump as practicable. Valves shall
be accessible at all times. Provide operational
arrangements for shutoff valve at the tanks from outside
the compartment in which they are located. The operating
gear for the shutoff valves at the tanks shall be
accessible at all times and shall be suitably marked.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2019
Resolution: Verified new fuel oil shutoff had been installed with proper markings.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 18 June 2019
Resolved
All exposed openings in the hull shall be made properly
watertight by the use of gaskets or similar devices, and
in all respects properly secured for sea before leaving
protected waters. Renew/replace damaged hinged hatch
cover and gasket to the starboard aft ballast tank.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2019
Resolution: Examined new hatch and gasket. Conducted NDT air lance on weld, all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 18 June 2019
Resolved
All exposed openings in the hull shall be made properly
watertight by the use of gaskets or similar devices, and
in all respects properly secured for sea before leaving
protected waters. Make repairs to damaged hatch leading
to the port side pump room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2019
Resolution: Area around hatch had been repaired, conducted visual examination.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 June 2019
Resolved
No repairs or alterations affecting the safety of the
vessel with regard to the hull, machinery, or equipment,
shall be made without the knowledge of the Officer in
Charge, Marine Inspection. Submit repair proposal to
address hole found in starboard skeg.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2019
Resolution: Verified repairs made to starboard skeg, sat air test was conducted on both skegs, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 September 2018
Resolved
Wires must be in an enclosure. Found improper dead end wire located in 02 deck port side aft. Remove or properly repair.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 October 2018
Resolution: Wires removed satisfactorily.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 25 September 2018
Resolved
Means for securing watertight scuttles shall consist of gaskets and clamping devices. QAWTS leading to ballast pump room missing securing device. Provide device.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 October 2018
Resolution: Installed securing device satisfactorily.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 September 2018
Resolved
Bilge and ballast piping systems must be so arranged as to prevent oil or water from the sea or ballast spaces from passing into cargo holds or machinery spaces, by the appropriate installation of stop and non-return valves. Prove proper operation of remote operating sea valve for ballast SW supply
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 October 2018
Resolution: Remote valve tested SAT.
Documentation › Certificates/Documents › Stability Letter
Issued 8 July 2016
Resolved
IAW the temporary loading authorization, serial: C1-1602432 issued by the USCG Marine Safety Center, the vessel is permitted to carry cargo under the operating restrictions listed on the temporary loading authorization until 31 August 2016. In order for the vessel to continue cargo operations after 31 August 2016, a new stability letter must be issued by the USCG Marine Safety Center.
Action required: 705 - Other - as specified
Due 31 August 2016
Resolved 22 September 2017
Resolution: Verified stability letter.
Construction/Loadline › Hull › Transverse Frame
Issued 10 June 2016
Resolved
Submit repair proposal and crop and renew fractured section of #1 transverse web frame and fractured section of connected vertical web frame.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 June 2016
Resolved 17 June 2016
Resolution: Received confirmation from ABS that the web frame in the port forepeak has been repaired and the fit-up, root pass and final weld inspections were all sat.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 10 June 2016
Resolved
Adjust watertight door to pump room and replace gasket. Conduct chalk test for tightness.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 June 2016
Resolved 19 July 2016
Documentation › Certificates/Documents › Stability Letter
Issued 10 June 2016
Resolved
Due to addition of 715 long tons of concrete over main deck, vessel is restricted from carrying cargo until vessel stability has been reviewed and approved by the Marine Safety Center
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2016
Resolved 8 July 2016
Construction/Loadline › Hull › Hull Plating
Issued 2 November 2015
Resolved
Crop and renew fractured plating in Void 02S and Void 03S to the satisfaction of class and CG.
Condition: Damaged By Earlier Event
Due 2 November 2015
Resolved 6 November 2015
Resolution: Repairs made to the satisfaction of the attending CG Marine Inspector.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 2 October 2015
Resolved
Repair or replace ground detection lamps for 240volt and 120volt systems.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 November 2015
Resolved 1 December 2015
Resolution: Received email from port engineer with photos showing new ground detection lamps installed and working.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 2 October 2015
Resolved
Repair or replace Ammeter and Frequency meter on main switchboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 November 2015
Resolved 1 December 2015
Resolution: Received email with photos from port engineer showing new ammeter and frequency meter installed and working.
Construction/Loadline › Structures › Rake
Issued 23 June 2014
Resolved
Provide repair proposal for #1 STBD bow rake 3-6 in. crack outboard on frame 2 3/4
Action required: 705 - Other - as specified
Due 23 July 2014
Resolved 1 December 2015
Resolution: Received class report showing these repairs were corrected and verified by ABS on 01AUG2014
Construction/Loadline › Structures › Rake
Issued 23 June 2014
Resolved
Provide repair proposal for fractured plate and weld at inboard frame 1 at longitudinal bulkhead (bottom of ladder) #1 STBD bow rake
Action required: 705 - Other - as specified
Due 23 July 2014
Resolved 1 December 2015
Resolution: Received class report showing that repairs were made and approved by ABS on 01AUG2014
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Overspeed Device
Issued 24 July 2012
Resolved
Prove proper operation of the low lube oil alarm and trip and the over speed shutdown for the main diesel ship service generator.
Action required: 705 - Other - as specified
Due 7 August 2012
Resolved 31 July 2012
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 8 July 2011
Resolved
Renew main deck port side fire extinguisher bracket. Bracket is severely corroded and is no longer mounted to bulkhead.
Action required: 705 - Other - as specified
Due 11 August 2011
Resolved 23 October 2011
Resolution: Fire extinguisher bracket renewed.
Electrical › Electric Supply System (service) › Cable
Issued 31 August 2010
Resolved
Remove or properly dead end wires located above generator motor. Replace wire strap located above generator motor.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 September 2010
Resolved 7 September 2010
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 31 August 2010
Resolved
Provide rubber matting for electrical panel located near generator.
Action required: 705 - Other - as specified
Due 30 September 2010
Resolved 7 September 2010
Fire Fighting › Portable CO2 Fire Extinguisher › Discharge Hose/Tube
Issued 31 August 2010
Resolved
Hose on #5 CO2 is wasted. Replace hose.
Action required: 705 - Other - as specified
Due 30 September 2010
Resolved 7 September 2010
Engineering › Fuel Oil Service System › Valve, Control
Issued 31 August 2010
Resolved
Stencil emergency F/O shutoff valve.
Action required: 705 - Other - as specified
Due 30 September 2010
Resolved 7 September 2010
Operations/Management › Pollution › Control of Discharge of Oil
Issued 31 August 2010
Resolved
Provide documentation for SOPEP required by CG letter to meet requirements of VRP IAW IMO Annex 8.
Action required: 705 - Other - as specified
Due 30 September 2010
Resolved 7 September 2010
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 22 December 2008
Resolved
-The SOPEP must amend all references to Regulation 26 of Annex I, to reference Regulation 37 of Annex I of the International Convention for the Prevention of Pollution from Ships.
Due 22 January 2009
Resolved 14 May 2009
Resolution: Deficiency addressed and SOPEP amended accordingly. SOPEP approval expires 11/14/2011.
Construction/Loadline › Hull › Longitudinal Frame
Issued 19 September 2004
Resolved
#5 Straboard ballast tank: C/R sidelong #3 @ forward bulkhead from bulkhead to seam about 3 feet.
Condition: Damaged By Earlier Event
Due 20 October 2004
Resolved 22 October 2004
Construction/Loadline › Hull › Bracket
Issued 19 September 2004
Resolved
#5 Stbd ballast tank: C/R gusset 2, 3 and 4 in outboard forward corner.
Condition: Damaged By Earlier Event
Due 20 October 2004
Resolved 22 October 2004
Construction/Loadline › Structures › Transverse Bulkhead
Issued 19 September 2004
Resolved
#5 Stbd ballast tank: C/R forward bulkhead between horizontals #1 - #4.
Condition: Damaged By Earlier Event
Due 20 October 2004
Resolved 22 October 2004
Construction/Loadline › Hull › Longitudinal Frame
Issued 19 September 2004
Resolved
#5 Stbd ballast tank: C/R sidelong #2 about 7 feet at the orward bulkhead.
Condition: Damaged By Earlier Event
Due 20 October 2004
Resolved 22 October 2004
Construction/Loadline › Hull › Transverse Frame
Issued 19 September 2004
Resolved
#5 Stbd ballast tank: C/R vertical frame #4 in way of the deckline to midpoint of sidelongs 4 and 5, about 8 feet.
Due 20 October 2004
Resolved 22 October 2004
Construction/Loadline › Hull › Transverse Frame
Issued 19 September 2004
Resolved
#5 Stbd ballast tank: C/R sidelong #3 at vertical frame #4 from 1 foot forward of frame to about 4 feet aft.
Due 20 October 2004
Resolved 22 October 2004
Construction/Loadline › Hull › Transverse Frame
Issued 19 September 2004
Resolved
stbd ballast tank #1: C/R sideshell vertical frame #1 1/4 aft of forward bulkhead about a six foot section.
Due 20 October 2004
Resolved 22 October 2004
Construction/Loadline › Hull › Longitudinal Frame
Issued 19 September 2004
Resolved
stbd ballast tank #1: C/R sidelong #2 about 4 feet length in way of sideshell vertical frame # 1 1/4.
Due 20 October 2004
Resolved 22 October 2004
Construction/Loadline › Hull › Bracket
Issued 19 September 2004
Resolved
Stb ballast tank #1: C/R gusset #4 in aft corner at ladder.
Due 31 December 2004
Resolved 19 September 2004
Construction/Loadline › Hull › Longitudinal Frame
Issued 7 September 2004
Resolved
V/W the #8 Bottom Long between Frames 2 and 3 in the Port Forward Rake.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 September 2004
Resolved 14 October 2004
Resolution: Repair completed.
Construction/Loadline › Hull › Hull Plating
Issued 7 September 2004
Resolved
Crop and Renew 4 FT by 6 FT area in vicinity of hull set in at deck line head long between Frames 1 and 2 of port forward rake at next drydock examination.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 December 2004
Resolved 2 May 2005
Construction/Loadline › Hull › Bottom Plating
Issued 7 September 2004
Resolved
Dewater lower centerline corner of port forward rake.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 September 2004
Resolved 14 October 2004
Resolution: Dewatering completed
Construction/Loadline › Hull › Longitudinal Frame
Issued 7 September 2004
Resolved
Re-weld #6 bottom long between Frames 1 and 2 in port forward rake.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 September 2004
Resolved 14 October 2004
Resolution: Repair completed
Construction/Loadline › Hull › Longitudinal Frame
Issued 7 September 2004
Resolved
Investigate small inset (6 in diameter) between Frames 2 and 3 IVO bottom long #6 in port forward rake. Report results to USCG at next drydock.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 December 2004
Resolved 14 October 2004
Resolution: Investigation complete. No significant damage found.
Construction/Loadline › Hull › Bracket
Issued 7 September 2004
Resolved
Investigate the #3 sidelong between Frames 2 and 3 from the forward bulkhead in the #3 Port Void. Report results to USCG.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 September 2004
Resolved 14 October 2004
Resolution: Investigation complete. Repaired cracked weld.
Construction/Loadline › Penetrations › Weld
Issued 7 September 2004
Resolved
Crop and Renew welded bolts and fillet welds from stern light install in Port Aft Rake at next drydock.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 December 2004
Resolved 2 May 2005
Construction/Loadline › Hull › Bracket
Issued 7 September 2004
Resolved
Crop and Renew #3 bracket and 4 ft of sidelong at aft bulkhead of #4 stbd void at next drydock. Investigate bulkhead and report results to USCG at next drydock.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 December 2004
Resolved 2 May 2005
Accommodation/Occupational Safety › Ventilation › General
Issued 7 September 2004
Resolved
Replace deck vent screens.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 October 2004
Resolved 22 October 2004
Electrical › Lighting (service) › Lighting Fixture
Issued 7 September 2004
Resolved
Repair 2 lights on car deck.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 September 2004
Resolved 14 October 2004
Resolution: Lights repaired.
Construction/Loadline › Hull › Hull Plating
Issued 7 September 2004
Resolved
Crop and Renew between sidelongs 2 and 3 and sidelongs 4 and 5 at Frame 11/sideshell vertical (4' X 18") at next drydock.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 December 2004
Resolved 7 September 2004
Deck/Cargo › Ballast › Tank
Issued 7 September 2004
Resolved
Make Ballast Tanks available for inspection.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 September 2004
Resolved 19 September 2004
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 7 September 2004
Resolved
Make Machinery available for inspection.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 September 2004
Resolved 14 October 2004
Resolution: Machinery Tested Sat
Construction/Loadline › Hull
Issued 16 September 2003
Resolved
Provide repair proposal for damage to frame 27 (watertight bulkhead) between #5 starboard ballast tank and #4 starboard void. Damage located at #3 - #4 sideshell longitudinals (2.5" - 3" inset).
Action required: 705 - Other - as specified
Due 25 September 2003
Resolved 23 September 2003
Construction/Loadline › Structures
Issued 16 September 2003
Resolved
Provide repair proposal for 2 areas presently weeping in watertight bulkhead at frame 27. Clean areas from both sides of the bulkhead and evaluate. LEGACY COMPONENT DESC: Transverse Bulkhead
Action required: 705 - Other - as specified
Due 25 September 2003
Resolved 23 September 2003
Construction/Loadline › Hull › Side Shell
Issued 16 September 2003
Resolved
Properly repair the damage to frame 27 (watertight bulkhead) between # 5 starboard ballast tank and # 4 starboard void. Damage located IWO # 3 side shell longitudinal (2 ½" - 3" inset).
Action required: 705 - Other - as specified
Due 31 October 2004
Resolved 2 May 2005
Construction/Loadline
Issued 5 September 2000
Resolved
Crop and renew 10 inch clad welded area (circle) located stbd side main deck 10 feet inboard of #2 ballast tank vent (IAW: procedurs outlined in NAVIC 7-68). Complete during next OCT01 DDX. IAW: 46 CFR 91-45-1, 91-45-5 AND NVIC 7-68.
Condition: Unknown
Due 5 September 2000
Resolved 5 September 2000
Electrical
Issued 5 September 2000
Resolved
Repair damaged lighting fixtures located throughout barge (replace damaged/missing covers). IAW: 46 CFR 111.75-20 (3) (b).
Condition: Unknown
Due 19 September 2000
Resolved 19 September 2000
Construction/Loadline
Issued 5 September 2000
Resolved
Paint loadline/draft marks (stbd side), ensure color is contrasting to hull. IAW: 46 CFR 97.40-10 (f).
Condition: Unknown
Due 19 September 2000
Resolved 19 September 2000
Construction/Loadline
Issued 17 October 1999
Resolved
Crop and renew buckled frame in the starboard #1 tank located 10' aft of watertight bulkhead outboard, IAW NVIC 7-68. (Deferred to the next dry- docking)
Condition: Unknown
Due 17 October 1999
Resolved 17 October 1999
Construction/Loadline
Issued 17 October 1999
Resolved
Renew missing under-deck longitudinal located in the #1 starboard void IWO the forward centerline bulkhead, IAW NVIC 7-68. (Deferred to the next dry- docking)
Condition: Unknown
Due 17 October 1999
Resolved 17 October 1999
Construction/Loadline
Issued 17 October 1999
Resolved
Crop and renew buckled side shell longs located IWO damaged areas describedin CG-835 #0006, (approx. 6' section) IAW NVIC 7-68. (Deferred to the next dry-docking)
Condition: Unknown
Due 17 October 1999
Resolved 17 October 1999
Construction/Loadline
Issued 17 October 1999
Resolved
Provide stitch welds as marked on 4-foot section of the #14 bottom longitudinal IWO the forward bulkhead in the #4 port void, IAW NVIC 7-68. (Deferred to the next dry-docking)
Condition: Unknown
Due 17 October 1999
Resolved 17 October 1999
Construction/Loadline
Issued 17 October 1999
Resolved
Clean and repaint plimsoll and draft markings as needed IAW 46CFR42.13-40 &46CFR97.40-10.
Condition: Unknown
Due 17 October 1999
Resolved 17 October 1999
Construction/Loadline
Issued 17 October 1999
Resolved
Replace missing securing bolts for the upper attachment of the forward ladder in the starboard #3 void.
Condition: Unknown
Due 4 December 1999
Resolved 1 December 1999
Construction/Loadline
Issued 17 October 1999
Resolved
Provide and install a pin for the lower universal joint on the outboard bilge eductor reach rod.
Condition: Unknown
Due 4 December 1999
Resolved 1 December 1999
Construction/Loadline
Issued 17 October 1999
Resolved
Properly gas free and ventilate the following tanks for CG inspection; Port& Starboard forward rake, Port voids #1-6.
Condition: Unknown
Due 4 November 1999
Resolved 5 November 1999
Construction/Loadline
Issued 17 October 1999
Resolved
Crop and renew lower 3-foot section of centerline bulkhead vertical post atframe #1 forward starboard rake, IAW NVIC 7-68.
Condition: Unknown
Due 18 November 1999
Resolved 22 November 1999
Construction/Loadline
Issued 17 October 1999
Resolved
Pickup welds in #1 port void at: lower end of outboard transverse diagonal at frame #4 & lower end of outboard vertical post at frame # 7, IAW NVIC 7-68. (Deferred to the next dry-docking).
Condition: Unknown
Due 17 October 1999
Resolved 17 October 1999
Construction/Loadline
Issued 17 October 1999
Resolved
Gouge and weld cracked weld of bottom long #8 between frames #1 & #2 in port rake, IAW NVIC 7-68. (Deferred to the next dry-docking)
Condition: Unknown
Due 17 October 1999
Resolved 17 October 1999
Construction/Loadline
Issued 17 October 1999
Resolved
Gouge and weld relief cut to bottom long #2 IWO frame #1 in port forward rake, IAW NVIC 7-68.
Condition: Unknown
Due 18 November 1999
Resolved 22 November 1999
Construction/Loadline
Issued 17 October 1999
Resolved
Make available for inspection, the topside of the insert located in the starboard #1 void overhead. Current insert appears to have a smaller insert within the larger insert.
Condition: Unknown
Due 19 October 1999
Resolved 5 November 1999
Construction/Loadline
Issued 17 October 1999
Resolved
Make the starboard forward rake available for inspection. Clean and inspect the aft watertight bulkhead at the noted deformity for structural soundness and watertight integrity.
Condition: Unknown
Due 4 November 1999
Resolved 5 November 1999
Construction/Loadline
Issued 17 October 1999
Resolved
Complete the installation of the deck insert in the after most section of the aft rake IWO stern log approx. 10' inboard of the port side-shell, IAW NVIC 7-68.
Condition: Unknown
Due 18 November 1999
Resolved 22 November 1999
Construction/Loadline
Issued 17 October 1999
Resolved
Reinstall the numeral "6" at the 16 foot draft mark located on the starboard bow IAW 46CFR97.40-10.
Condition: Unknown
Due 17 October 1999
Resolved 17 October 1999
Construction/Loadline
Issued 17 October 1999
Resolved
Gouge and reweld crack weld on bottom longitudinal IWO the forward outboardcorner of the sea chest IAW NVIC 7-68. (Deferred to the next dry-docking)
Condition: Unknown
Due 17 October 1999
Resolved 17 October 1999
Electrical
Issued 22 September 1998
Resolved
Prove water tightness of stern Nav light battery box.
Condition: Unknown
Due 22 September 1998
Resolved 22 September 1998
Electrical
Issued 22 September 1998
Resolved
Prove proper repair or replacement of broken light fixtures in forecastle.
Condition: Unknown
Due 22 September 1998
Resolved 22 September 1998
Construction/Loadline
Issued 22 September 1998
Resolved
Prove proper repairs to damaged and missing hand rails on loading ramp in forecastle.
Condition: Unknown
Due 22 September 1998
Resolved 22 September 1998