Inspection history · 85
14 September 2021
Administrative Inspection · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7312032
10 September 2021
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7309203
8 October 2020
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7101527
21 July 2020
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7012237
24 April 2020
Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6942768
9 July 2019
Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6720502
17 May 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6692725
2 April 2018
MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6380624
10 October 2017
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6286265
14 August 2017
Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6237417
10 August 2017
Administrative Inspection · Permit to Proceed
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6236699
2 February 2017
MTSA Verification · Examination of Repairs · MARPOL Annex I Examination · Cargo Tank Internal · COI Inspection · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6079905
15 December 2016
Damage Survey · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6060006
17 November 2016
Damage Survey · Examination of Repairs · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6042841
10 November 2016
Damage Survey
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6040880
3 October 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6014641
30 September 2016
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6013029
23 August 2016
COI Inspection · MARPOL Annex VI Survey · Deficiency Check · MTSA/ISPS Verification · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5976329
30 October 2015
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5754495
22 September 2015
MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5724479
9 August 2015
Deficiency Check · Permit to Proceed
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5210721
9 August 2015
Permit to Proceed · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5212030
21 May 2015
Examination of Repairs · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5118299
24 December 2014
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5040246
11 December 2014
MTSA/ISPS Verification · MARPOL Annex I Examination · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5036038
4 November 2013
Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4740347
19 October 2012
Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4465463
8 May 2012
Drydock Exam · Internal Structural Exam · Cargo Tank Internal
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4305596
27 February 2012
Damage Survey · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4251893
22 November 2011
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4193736
13 October 2011
COI Inspection · MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4166296
17 June 2011
Damage Survey · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4047971
16 June 2011
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4047630
6 December 2010
Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3902593
12 July 2010
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3796059
8 March 2010
Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3692009
15 January 2010
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3663481
6 January 2010
Annual Inspection · MTSA Verification · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3657687
3 November 2008
MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3354318
16 January 2008
Ballast Water Examination · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3130622
5 October 2007
Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3075975
25 September 2007
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3066457
21 March 2007
Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2891942
12 October 2006
COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2797665
30 November 2005
Periodic Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2543813
29 June 2005
Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2407739
24 May 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2367581
24 May 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2368638
18 November 2004
MARPOL Annex II Examination · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2243833
26 October 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2228552
17 June 2004
MTSA Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2110670
17 February 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2016373
28 December 2003
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1970656
12 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1980820
20 November 2003
Deficiency Check · Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1951683
7 October 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1923414
17 August 2003
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1878566
13 July 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1923319
23 January 2003
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1734518
13 September 2002
COI Inspection · Hull Examination · Cargo Tank Internal · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1658478
24 October 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 765653
21 October 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 189587
16 October 2001
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1073753
10 September 2001
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1072881
22 August 2001
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1071160
13 August 2001
Deficiency Check · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1426643
30 May 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 768455
29 May 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 199213
15 December 2000
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 188060
29 November 2000
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 824107
14 November 2000
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1055826
31 October 2000
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1471901
20 October 2000
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1057238
9 September 2000
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 822405
11 November 1999
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 806265
10 September 1999
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1391097
14 August 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 521991
21 June 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 139887
10 December 1998
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 509861
28 October 1998
Re-Inspection · Damage Survey
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1449113
1 October 1998
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 800954
13 March 1998
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 450003
31 October 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 500495
25 September 1997
Initial Certification · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1447733
7 July 1997
Construction Oversight
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1461807
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 14 September 2021
Resolved
Any International Oil Pollution Prevention certificate shall be issued to any oil tanker 150 gross tonnage and any other ships of 400 fross tonnage and above which are engaged in voyages to port or offshore terminals under the jurisdicition of parties to the present convention.
The vessel does not have a valid IOPP.
MARPOL I/7(1)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 14 October 2021
Resolved 15 September 2021
Resolution: Received provisional IOPP
01 - Certificates & Documentation › 011 - Ships Certificates › International Air Pollution Certificate (IAPP)
Issued 14 September 2021
Resolved
An IAPP shall be issued to any ship of 400 gross tonnage and above engaged in voyages to port or offshore terminals under the Jurisdiction of other parties.
The vessel does not have a valid IAPP.
MARPOL VI/6.1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 14 October 2021
Resolved 15 September 2021
Resolution: Received IAPP
01 - Certificates & Documentation › 013 - Documents › SOPEP
Issued 14 September 2021
Resolved
Every oil tanker of 150 gross tonnage and above and every ship other than an oil tanker of 400 gross tonnage and above shall carry on board a shipboard oil pollution emergency plan approved by the administration. The vessel does not carry a shipboard oil pollution emergency plan approved by the administration.
MARPOL I/37(1)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 14 October 2021
Resolved 15 September 2021
Resolution: Received provisional IOPP
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 September 2021
Resolved
No ship to which the present convetion applies shall proceed to sea on the international voyage unless it has been surveyd, marked, and provided with the international load line certificate. Vessek does not have a load line certificate.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 14 October 2021
Resolved 15 September 2021
Resolution: Received provisional Load Line
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Compliance (COC)
Issued 10 September 2021
Resolved
Certificates of Inspection will be issued for a period of 5 years; invalid COI. Vessel missed annual inspection.
Complete COI Inspection prior to conducting cargo operations.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 October 2021
Resolved 18 October 2021
Resolution: Vessel changed flag to Liberia, demonstrated approprate inspections conducted by flag state
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 July 2020
Resolved
Vessel must undergo a periodic inspection within three months before or after the second or third anniversary date of the vessel's COI. Vessel did not conduct satisfactory inspection within the allowable window. Conduct satisfactory operation to the satisfaction of the attending marine inspector prior to carrying cargo and/or conducting cargo operations.
46 CFR 31.10-17
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 October 2021
Resolution: Vessel changed flag to Liberia, demonstrated approprate inspections conducted by flag state
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 21 December 2016
Resolved
Vessel has a 1" crack in the #1 stbd cargo tank approx. 28' off of bottom plate, a 1" crack in the #1 port cargo tank approx. 32' off of bottom plate, & a 1" fracture in the #5 stbd cargo tank aft bulkhead. Vessel was issued a permit to proceed to Port Arthur, TX to effect permanent repairs. Prior to loading cargo, permanent repairs shall be tested in the presence of a Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 December 2016
Resolved 7 April 2017
Resolution: Vessel has completed major repairs of cargo and ballast tank.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 15 December 2016
Resolved
Vessel has a fracture in the floor of #4 stbd cargo tank in a weld seam at transverse frame #38 and longitudinal frame #10. Vessel has a hole between #4 and #5 ballast tanks.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2016
Resolved 21 December 2016
Resolution: Received tech report from Boland Marine attesting to repairs and certified by ABS Surveyor.
Construction/Loadline › Structures › Deck Plating
Issued 10 November 2016
Resolved
Submit repair plan for wasted metal under deckhouse on tank top hold #4 to OCMI in Tampa prior to repairs being made.
Action required: 705 - Other - as specified
Resolved 23 November 2016
Resolution: Deck plate under Port Engine House was replaced at Gulf Marine Repair in Tampa, Fl.
Deck/Cargo › Cargo Heating › General
Issued 30 September 2016
Resolved
Provide class report attesting to the satisfactory repair and operation of port and starboard thermal fluid heaters prior to conducting cargo operations requiring the use of thermal fluid heaters.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2016
Resolved 30 September 2016
Resolution: Received class report attesting to proper repairs and testing.
Deck/Cargo › Cargo Heating › General
Issued 23 August 2016
Resolved
Conduct all required thermal fluid heater test on both units in the presence of the attending USCG Marine Inspector prior to loading cargo that requires their use.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 August 2016
Resolved 24 August 2016
Resolution: All tests conducted.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 23 August 2016
Resolved
Prove proper operation of the starboard cargo pump shut down in the presence of the attending marine inspector prior to the discharge of cargo.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 August 2016
Resolved 24 August 2016
Resolution: Tested emergency shutdowns on both pumps.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 23 August 2016
Resolved
Clean or repair rising sticks so that they are readable prior to loading cargo.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 August 2016
Resolved 24 August 2016
Resolution: Meter sticks properly cleaned.
Deck/Cargo › Cargo Stowage › General
Issued 30 October 2015
Resolved
Two cracks ID'd in #5 Cargo Tank bottom where it meets the aft bulkhead. Provide ABS approved repair plan and cognizant OCMI must witness repair test prior to sail/cargo.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 30 November 2015
Resolved 6 November 2015
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 9 August 2015
Resolved
Vessel has a 12" in fracture to the #2 Port Cargo tank in the deck weld location. Vessel has been issued a Permit to Proceed to Tampa, Fl after affecting temp repairs to offload cargo. Once offloaded vessel is to make permanent repairs using the guidance in NVIC 7-68 and have the repairs tested in the presence of a Marine Inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 28 August 2015
Resolution: Attended vessel for permanent crop and renew repair verification. Satisfactorily observed weld repairs in no.1 and no. 2 centerline Cargo Tanks, no. 1 and no. 2 starboard side wing voids, and deck around effected area. ABS also in attendance.
Deck/Cargo › Ballast › Tank
Issued 21 May 2015
Resolved
Make permanent repair to crack on tank side of #1 port ballast tank. 46 CFR 31.10-21
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2015
Resolution: Repairs made to the satisfaction of the attending MIs.
Deck/Cargo › Ballast › Tank
Issued 21 May 2015
Resolved
Provide gauging reports for pitting in bottom plating of #5 port ballast tank, bay #2 as well as vessel's original scantlings. 46 CFR 31.10-21
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2015
Resolution: POC provided gauging test report of suspect area. Report uploaded to this activity.
Deck/Cargo › Ballast › Tank
Issued 21 May 2015
Resolved
Repair cracked welds in #4 port ballast tank on tank side bulkheads in bays 1, 2, 4, & 6. 46 CFR 31.10-21
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2015
Resolution: Cracked welds repaired to satisfaction of attending MIs.
Deck/Cargo › Ballast › Tank
Issued 21 May 2015
Resolved
Repair cracked welds in #3 starboard ballast tank on tank side bulkheads in bays 4, 6, 7, & 8. 46 CFR 31.10-21
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2015
Resolution: Welds repaired to the satisfaction of the attending MIs.
Deck/Cargo › Ballast › Tank
Issued 21 May 2015
Resolved
Repair cracked weld on frame #25 in #2 starboard ballast tank. 46 CFR 31.10-21
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2015
Resolution: Frame weld repair made to the satisfaction of the attending MIs.
Deck/Cargo › Ballast › Tank
Issued 21 May 2015
Resolved
Repair cracked weld on Frame #23 in #2 starboard ballast tank. 46 CFR 31.10-21
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2015
Resolution: Weld repaired to the satisfaction of the attending MIs.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 21 May 2015
Resolved
Repair cracked weld on aft bulkhead of bow thruster room. 46 CFR 31.10-21
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 August 2015
Resolution: Repairs were made and attested to by attending ABS surveyors.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 21 May 2015
Resolved
Make repairs to exhaust lagging in bow thruster room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2015
Resolution: Repairs made to the satisfaction of the attending MIs.
Deck/Cargo › Cargo Heating › General
Issued 11 December 2014
Resolved
VSL crew could not demonstrate proper operation and required shutdowns for the port thermal fluid heater, TFH was having flame failures as well as not shuting down when conducting low air flow op test. Was unable to inspect internal combustion chamber due to crew working on system.
Action required: 705 - Other - as specified
Due 30 December 2014
Resolved 24 December 2014
Resolution: Conducted test of all required alarms and shutdowns.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 11 December 2014
Resolved
#3 Port Overfill/High Level alarm would not display and audible or visual indication during operational test.
Action required: 705 - Other - as specified
Due 30 December 2014
Resolved 11 December 2014
Resolution: Crew was able to repair high level indicating device while on board.
Fire Fighting › Portable CO2 Fire Extinguisher › Discharge Hose/Tube
Issued 13 October 2011
Resolved
13 Oct 2011: Type V fire extinguisher has a wasted hose.
Due 13 November 2011
Resolved 22 November 2011
Communications › Internal Communications System › Portable Radios
Issued 13 October 2011
Resolved
13 Oct 2011: The bow thuster is operated locally by radio communication with the tug. Instuctions need to be updated to reflect this.
Due 13 November 2011
Resolved 22 November 2011
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 13 October 2011
Resolved
13 Oct 2011: A calibration certificate needs to be provided for the cargo dishcharge gauges.
Due 13 November 2011
Resolved 22 November 2011
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 October 2011
Resolved
13 Oct 2011: Provide and install protective guard over flywheel for the bow thuster engine.
Due 13 November 2011
Resolved 22 November 2011
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 13 October 2011
Resolved
13 Oct 2011: The following hoses need to be renewed to meet SAE J1942 standards. #1 ship service generator blower oil hose, #3 Ship service generator fuel gauge hose, #1 Hydraulic engine fuel return hose, #2 hydraulic engine blower oil hose.
Due 13 November 2011
Resolved 20 October 2011
Resolution: Received receipt from vsl verifying that new hoses had been ordered and are onboard.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 17 June 2011
Resolved
The CG received notice that the ACADI has damage/cracks in the #5 cargo tank aft bulkhead. Vessel is to discharge cargo, gas free all compartments, tanks and voids in the area of the damage and make vessel availible for a Coast Guard Marine Inspector prior to departing the Port of Tampa.
Action required: 705 - Other - as specified
Due 17 June 2011
Resolved 20 June 2011
Resolution: Inspected
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 17 June 2011
Resolved
The crack leaking cargo in the #5 starboard cargo tank aft bulkhead (fr 50) at the tank bottom and the 1st swash bulkhead inboard from starboard and a crack leaking cargo in the #5 port cargo tank in way of an old repair (doubler) also located in the aft bulkhead (fr 50) at the tank bottom 4th swash bulkhead inboard from port. Crop & renew both areas.
Action required: 705 - Other - as specified
Due 20 June 2011
Resolved 26 June 2011
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 17 June 2011
Resolved
2 cracked and wasted welds on the 1st and 2nd swash bulkheads from the portside at the same level where the #5 port cargo tank bottom meets the aft bulkhead. Prior to loading cargo, make repairs.
Action required: 705 - Other - as specified
Due 20 June 2011
Resolved 26 June 2011
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 6 December 2010
Resolved
1. To be completed prior to 6 Jan 2011: Hose certificate on board for hose # SBHTA 225 0459 does not match the actual hose on board with a # SBHTA 225 0463. The two other hoses on board have matching certificates. Prior to using hose # SBHTA 225 0463 it must be properly tested and documented.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 January 2011
Resolved 10 December 2010
Resolution: Recieved via email a copy of the hose certificate for the hose on board with a # SBHTA 225 0463.
Construction/Loadline › Markings › Fresh Water Load Line
Issued 20 February 2010
Resolved
The load line trees do not reflect service marking iaw with ABS certificate. Vessel to permanently affix marking next dry docking.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2010
Resolved 14 April 2010
Deck/Cargo › Cargo Heating › General
Issued 7 January 2010
Resolved
There is two minute leaks on the port thermal fluid heater piping near the heater/boiler. It is suspected the leaks can be corrected by tightening with wrenches. Make proper repairs to all thermal fluid leaks in piping when lines are cool and before next cargo.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 January 2010
Resolution: The flange bolts were tightened and the pooling fluid was wiped up with rags. The repairs are satisfactory and approved by ABS and USCG Marine Inspector.
Deck/Cargo › Cargo Heating › General
Issued 7 January 2010
Resolved
The thermal fluid heater test procedures have been ammended due to upgrades in the control system. Barge tankerman have new procedures via manufacturer but they are not approved by Marine Safety Center. Sumbit procedures for proper approval and maintain copy o/b vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2010
Resolved 29 March 2010
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 7 January 2010
Resolved
An accumulation of hydraulic oil has built up in the bow thruster room bilges. Remove oil from bilges and remove potential source of leaking oil.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 January 2010
Resolved 22 January 2010
Resolution: The bow thruster rams were removed, renewed, and reinstalled. The oil in the bilge was removed. Repairs satisfactory to ABS and the USCG Marine Inspector.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 7 January 2010
Resolved
There is a temp repair made by the crew to the aft diesel fuel tank on barge. Tank serves all prime movers on barge. The repair is an unauthorized epoxy patch on an approx 18" crack. The fuel level is kept below the crack but still needs to be repaired via proper reporting and repair procedures.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2010
Resolved 14 April 2010
Stability › Watertight Integrity › General
Issued 7 January 2010
Resolved
Both the bow thruster room wtd and the aft rake wtd do not seal as designed. WTDs are heavily corroded allowing the door rubber seals to flip on edge and not seal properly. Repair/replace wtd and chalk test to prove adeqaucy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 January 2010
Resolved 22 January 2010
Resolution: The WTD''s rubber seals for the Bow Thruster compartment and Aft Rake were replaced. The WTD''s satisfactorily passed the chalk test for the ABS surveyor. All corroded WTD''s will be replaced or repaired during the barges scheduled drydock in April 2010.
Stability › Weathertight Integrity › General
Issued 7 January 2010
Resolved
Several weather tight doors throughout the barge are heavily corroded and do not seal appropriately. Make repairs to all weather tight doors throughout the barge so they seal as designed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2010
Resolved 14 April 2010
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 7 January 2010
Resolved
The aft rake space has numerous full paint cans and fuel and cargo samples stored. In order to store these items the space must have fixed fire fighting, structural fire protection and approved ventilation system. Remove all paint supplies and samples from space or submit plans to MSC to certify space for such hazmat storage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 January 2010
Resolved 22 January 2010
Resolution: The paint cans were removed from the space and satisfactorily inspected by the USCG Marine Inspector.
Electrical › Electrical Distribution System (service) › Cable
Issued 7 January 2010
Resolved
There is a dead end wire where the aft rake heater used to be before the space flooded. Remove dead end wire or replace the old space heater.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 January 2010
Resolved 22 January 2010
Resolution: The dead end wires were placed in a junction box, which was to the satisfaction of the ABS surveyor and USCG Marine Inspector.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 7 January 2010
Resolved
Conduct hydrostatic test on diesel fuel hose (3 inch) as required by 33 CFr 156.170. The hose is to be tested once a year to 1.5 MAWP. Also label hose for oil service as required.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 January 2010
Resolved 22 January 2010
Resolution: The vessel conducted a hydrostatic test on the diesel oil transfer line and was supplied with a new transfer hose with applicable certificates to verify test at 225psi. Test was satisfactory to the USCG Marine Inspector.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 7 January 2010
Resolved
The #3 cargo tank hi level indicator is inoperative. Make repairs to indicator/sensor in order to alarm at 95% and 98% tank capacity as designed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2010
Resolved 29 March 2010
Deck/Cargo › Cargo Heating › General
Issued 7 January 2010
Resolved
Replace temp copper line on port thermal fluid heater. Copper line rerplaced an original stainless steel line which provides measurement of differential pressure of heated oil.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 14 January 2010
Resolved 22 January 2010
Resolution: The temporary copper differential pressure pipe was replaced with a new stainless steel pipe and inspected by ABS and USCG Marine Inspectors. Repairs satisfactory.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 6 January 2010
Resolved
The J box for the Omni Bow Thruster is corroded heavily and will not close/protect as designed. Door is held shut by string. Replace J box by upcoming ddx.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2010
Resolved 14 April 2010
Deck/Cargo › Cargo Heating › General
Issued 6 January 2010
Resolved
During examination of test procedures the combustion air switch on the port heater appeared to be inconsistent in operation on shutdown mode. There is confusion as to whether the switch only works in low fire situation but the procedures do not reflect this. Vessel to repair switch or amend test procedures to make correct.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2010
Resolved 29 March 2010
Resolution: Combustion air switch only works in low fire mode. Test procedures have been amended to reflect this.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 16 January 2008
Resolved
Failure to conduct annual or periodic inspection of a tank vessel, 1600 GT or more. Annual inspection was conducted 4 days after the 3 month COI anniversary date window.
Due 16 January 2008
Resolved 16 January 2008
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 11 May 2007
Resolved
Provide USCG/ABS approval letter/approved plans for the new liquid level gauging system on this barge
Due 11 June 2007
Resolved 12 October 2007
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 11 May 2007
Resolved
Provide ABS dry dock /cargo tank internal exams report
Due 11 June 2007
Resolved 12 October 2007
Engineering
Issued 20 November 2003
Resolved
Repair or replace inoperative supply fans in generator deck house.
Due 20 December 2003
Resolved 1 December 2003
Engineering › Thrusters › Motor
Issued 20 November 2003
Resolved
Repair/ replace/ remove bow thruster prime mover.
Action required: 705 - Other - as specified
Due 12 August 2007
Resolved 12 October 2006
Resolution: Observed proper operation of bow thruster
Engineering › Generator (propulsion/auxiliary-electric)
Issued 13 September 2002
Resolved
Test #3 generator low lube oil shut down to the satisfaction of cognizant [name withheld]: low lube shutdown
Due 11 October 2002
Resolved 23 January 2003
Documentation › Safety/Response Plans/Programs
Issued 13 September 2002
Resolved
Provide proof of SOPEP annual review was conducted and provide copy of letter to MSC. LEGACY COMPONENT DESC: SOPEP
Due 27 September 2002
Resolved 23 September 2002
Resolution: Received fax of Penn Maratime Inc. letter dated 1 September, 2002 (Certiying Statement of Compliance.)
Electrical
Issued 13 August 2001
Resolved
PROVE PROPER OPERATION OF #3 GENERATOR. (STARTING BATTERY WAS DEAD DURING INSPECTION)
Condition: Unknown
Due 13 September 2001
Resolved 13 September 2001
Deck/Cargo
Issued 13 August 2001
Resolved
REPAIR TACHOMETER ON CARGO PUMP ENGINE.
Condition: Unknown
Due 13 September 2001
Resolved 13 September 2001
Electrical
Issued 13 August 2001
Resolved
REPAIR OR REPLACE BROKEN TACHOMETER ON #2 GENERATOR
Condition: Unknown
Due 13 September 2001
Resolved 13 September 2001
Deck/Cargo
Issued 31 October 2000
Resolved
Make permanent repairs to leaky #2 cargo pump prior to use.
Condition: Unknown
Due 31 October 2000
Resolved 31 October 2000
Deck/Cargo
Issued 31 October 2000
Resolved
Repair or replace valve position indictors as needed for all cargo tank valves.
Condition: Unknown
Due 31 October 2000
Resolved 31 October 2000
Construction/Loadline
Issued 31 October 2000
Resolved
Make permanent repair to crack in #1 cargo tank, port side adjacent to #2 cleat. Vessel not to load any cargo in #1 tank closer than one (1) foot below level of tank crack.
Condition: Unknown
Due 31 October 2000
Resolved 31 October 2000
Lifesaving
Issued 31 October 2000
Resolved
Remove paint and thinners from non authorized paint locker storage areas ormodify to meet requirements of paint locker storage.
Condition: Unknown
Due 31 October 2000
Resolved 31 October 2000
Accommodation/Occupational Safety
Issued 31 October 2000
Resolved
Properly install MSD.
Condition: Unknown
Due 31 October 2000
Resolved 31 October 2000
Deck/Cargo
Issued 31 October 2000
Resolved
Prove proper operation of high temp alarm on thermal fluid heater.
Condition: Unknown
Due 31 October 2000
Resolved 31 October 2000
Deck/Cargo
Issued 31 October 2000
Resolved
Repair all inoperative gauges on both cargo pumps.
Condition: Unknown
Due 31 October 2000
Resolved 31 October 2000
Engineering
Issued 31 October 2000
Resolved
Label fuel shut-off valves to bow thruster.
Condition: Unknown
Due 30 November 2000
Resolved 1 November 2000
Engineering
Issued 31 October 2000
Resolved
Repair electrical contact box on prime mover to ensure complete closure.
Condition: Unknown
Due 30 November 2000
Resolved 1 November 2000
Engineering
Issued 31 October 2000
Resolved
Repair leaking salt water cooling line to bow thruster.
Condition: Unknown
Due 31 October 2000
Resolved 31 October 2000
Deck/Cargo
Issued 31 October 2000
Resolved
Secure port aft hydraulic lines to mounting bracket (capstan).
Condition: Unknown
Due 31 October 2000
Resolved 31 October 2000
Deck/Cargo
Issued 31 October 2000
Resolved
Repack #1 STBD cargo valve reach rod.
Condition: Unknown
Due 31 October 2000
Resolved 1 November 2000
Deck/Cargo
Issued 31 October 2000
Resolved
Repair leaking hydraulic line to capstan.
Condition: Unknown
Due 31 October 2000
Resolved 31 October 2000
Accommodation/Occupational Safety
Issued 31 October 2000
Resolved
Replace missing port aft safety railing.
Condition: Unknown
Due 31 October 2000
Resolved 31 October 2000
Navigation
Issued 10 September 1999
Resolved
REPAIR WHITE STERN LIGHT ON BARGE.
Condition: Unknown
Due 10 September 1999
Resolved 10 September 1999
Electrical
Issued 10 September 1999
Resolved
REPAIR EMERGENCY LIGHT IN BOW THRUSTER ROOM.
Condition: Unknown
Due 10 September 1999
Resolved 10 September 1999