Records from 1999 to 2025. Most recent: inspection, 22 October 2025.
Documentation record
Registered dimensions (L × B × D)100.0 ft × 40.0 ft × 17.2 ft
Registered tonnagegross 98 / net 67
ITC dimensions (L × B × D)100.0 ft × 40.0 ft × 17.2 ft
ITC tonnagegross 416 / net 124
BuilderBOLLINGER SHIPYARDS LLC · LOCKPORT, LA, UNITED STATES · built 1999
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 January 2026 · expires 28 February 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
416 - Convention (Subpart B), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
124 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 25
22 October 2025
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8257087
13 November 2024
Administrative Inspection · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8034407
21 August 2024
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7974978
21 July 2024
Damage Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7963286
21 July 2024
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7971471
2 June 2024
Damage Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7925340
31 January 2024
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7858623
27 February 2023
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7642633
18 March 2022
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7414235
4 February 2021
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7135819
16 January 2020
COI Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6890852
17 May 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6692725
22 January 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6613662
19 January 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6646722
18 January 2017
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6072869
5 June 2013
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4613907
6 May 2010
Industry Initiated Exam · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3743522
25 November 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3428649
1 September 2006
MTSA Verification · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2766065
24 July 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2723347
24 July 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2723382
10 January 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2283666
18 November 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1951432
30 November 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 770527
25 November 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 200821
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 2 December 2024
Resolved
Each towing vessel must have a reliable means to provide notification via a Low hydraulic steering fluid alarm. The alarm worked when manually activated, but the piping from the tank was mot installed. Install piping and open the valve leading to the alarm.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2025
Resolved 3 December 2024
Resolution: Vessel built to ABS Class standards.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 2 December 2024
Resolved
Each towing vessel must be equipped with gauges at the machinery location for Main engine cooling water temperature. Both Main engines gauges were INOP.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2025
Resolved 3 December 2024
Resolution: Murphy switched connected adn tested satisfacory.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 December 2024
Resolved
Electrical components that pose an electrical hazard must be in an enclosure. The forward port engine room bulkhead wiring to the electrical outlet was not in a junction box. The wire should be secured or removed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2025
Resolved 3 December 2024
Resolution: Tied into junction box.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 21 July 2024
Resolved
An existing vessel may be deemed by the OCMI to be in compliance with this subpart provided that either: (b) The vessel has both been in satisfactory service insofar as structural adequacy is concerned and does not cause the structure of the vessel to be questioned by the OCMI.
The VERA BISSO was involved in a marine casualty on 21JUL2024 and received damage to the bulwark, stiffeners/brackets, and 42inx42in deck area on the starboard aft quarter, and two starboard transverse frames inside the steering space as a result. Permanent repairs to be made to the satisfaction of an attending Marine Inspector.
The vessel is authorized a one-time transit to LMR MM106 repair yard as identified by O/O.
Action required: 705 - Other - as specified
Resolved 18 September 2024
Resolution: Received, reviewed, and accepted survey report from ABS attesting to the satisfactory repairs of damaged bulwark and deck area on starboard aft quarter.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 2 June 2024
Resolved
A towing vessel 26 feet or more in length and more than 600 horsepower, engaged in commercial service must have on board a properly installed, operational Coast Guard type-approved AIS Class A Device. The vessel's AIS is reported to not be functional.
Vessels is restricted to operate only within their operating zone of 3-4 miles of MM229.3. The VERA BISSO must communicate with VTS prior to making any vessel movements and make aware their intentions to any passing vessels.
Action required: 705 - Other - as specified
Due 9 June 2024
Resolved 2 June 2024
Resolution: Technician fixed AIS.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 March 2022
Resolved
Each towing vessel must have an alarm for low level in the fuel day tanks. Install low level alarms on fuel day tanks during next scheduled drydock.
Action required: 705 - Other - as specified
Due 17 January 2025
Resolved 21 March 2022
Resolution: Vessel provided evidence for being built to class, therefore IAW 46 CFR 143.215 they are in compliance.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 March 2022
Resolved
Electrical systems must minimize shock hazards. Install missing covers over open blanks in wheelhouse breaker panel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 April 2022
Resolved 27 April 2022
Resolution: Blank installed.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 18 March 2022
Resolved
Each ship subject to the Bridge-to-Bridge Act must have on board a radio operator who holds a restricted radio-telephone operator permit or higher class license. Master must obtain license as stated above.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 April 2022
Resolved 27 April 2022
Resolution: License obtained.
10 January 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 2283666
25 November 2008Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 3428649
5 June 2013Routine · role: Involved in a Marine Casualty · activity 4613907
19 January 2019Routine · role: Involved in a Marine Casualty · activity 6646722
17 May 2019Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6692725
21 July 2024Routine · role: Involved in a Marine Casualty · activity 7971471
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source:
IIR, through 2026.