MAURY USCG vessel records
← All vessels

MM 110

MM 110 is a 1998 tank barge. The Coast Guard has recorded 48 inspections since 1998, most recently in September 2025, along with 15 deficiencies — 1 with no resolution recorded —.

Records from 1998 to 2025. Most recent: inspection, 23 September 2025.

Built
1998
Last inspected
23 September 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 23 September 2025
…with no type recorded6
Operational controls None recorded without a removal date
Years with a record 25 calendar years (1998–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

472305
Flag
UNITED STATES
Maury page id
psix-472305

Documentation record

Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE INDUSTRIES · ASHLAND CITY, TN, UNITED STATES · built 1998
Hull materialSteel
PropulsionNone
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 6 January 2026 · expires 31 January 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Net Ton
1619 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 10

Inspection history · 48

23 September 2025 Periodic Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 8239484
15 October 2024 Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 8018930
6 November 2023 Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7798625
29 September 2022 Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7568441
20 January 2022 Periodic Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7383046
9 November 2020 Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7092152
20 November 2019 Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6858984
19 September 2019 Administrative Inspection
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6815975
23 July 2019 Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6760563
12 December 2018 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6596768
21 August 2018 Administrative Inspection
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6518822
7 November 2017 Cargo Tank Internal · COI Inspection · Drydock Exam · Examination of Repairs · MTSA Verification · Administrative Inspection · Internal Structural Exam · Damage Survey
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6302370
23 September 2016 Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6007626
4 December 2015 Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5775337
19 November 2014 Examination of Repairs · Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5026969
9 November 2014 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5021083
9 November 2014 Damage Survey · Permit to Proceed
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5022866
29 October 2014 Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5014493
1 October 2014 MTSA Verification · Periodic Inspection · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4996707
17 March 2014 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4817507
3 March 2014 MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4809264
17 October 2012 COI Inspection · Internal Structural Exam · Examination of Repairs · Administrative Inspection · MTSA Verification · In-Service Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4495698
18 July 2012 Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4383222
22 November 2011 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4195204
1 November 2010 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3889748
7 September 2010 Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3844113
22 February 2010 Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3684038
5 November 2008 MTSA Verification · Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3357792
2 October 2007 Cargo Tank Internal · Examination of Repairs · Administrative Inspection · Deficiency Check · MTSA Verification · Internal Structural Exam · COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3071510
10 July 2007 MTSA Verification · Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2995427
11 July 2006 MTSA Verification · Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2710233
5 May 2005 Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2350132
15 April 2005 MTSA Verification · COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2334563
11 February 2005 Examination of Repairs
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2292047
9 June 2004 Periodic Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2097754
8 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1997447
20 May 2003 Periodic Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 1797596
30 April 2003 Administrative Inspection
Administrative · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 1783494
17 July 2002 Periodic Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1647865
17 April 2001 Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1472555
18 April 2000 COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1415346
2 July 1999 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1092249
5 May 1999 Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1447945
12 March 1999 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 32846
12 March 1999 Damage Survey
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1432134
14 August 1998 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 769057
11 August 1998 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 210460
30 April 1998 Initial Certification · Hull Examination · Construction Oversight
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1419935

Deficiency record · 15

02 - Structural Conditions › N/A - No Subsystem › Cargo tank vent system
Issued 15 October 2024 No resolution recorded
The cargo tank safety relief valves shall be inspected at least once in every 2 years.(b) The safety relief valve discs must be lifted from their seats in the presence of a marine inspector by either liquid, gas, or vapor pressure at least once every 5 years to determine the accuracy of adjustment and, if necessary, must be reset. Vsl currently used for Grade D/E cargo and has gooseneck and flame screen ventilation installed. Prior to the carriage of any cargoes requiring the use of PV valves per this vsl's CAA inspected PV valves are to be installed and to the satisfaction of the Marine inspector. 46CFR38.25-10(a)(b)
Action required: 705 - Other - as specified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 January 2022 Resolved
All exposed and dangerous places such as gears and machinery shall be properly protected with covers, guards or rails in order that the danger of accidents may be minimized. The rotating equipment around the diesel engine jacket water cooling fan is not guarded. Install guards to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 February 2022
Resolved 2 February 2022
Resolution: MI accepted photos of guards in place.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 20 November 2019 Resolved
Vessel had previous company's transfer procedures and benzene plan onboard.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 November 2019
Resolved 20 November 2019
Resolution: New owner updated all documents before the end of the inspection
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 November 2019 Resolved
small smooth inset on the deck gunwhale of the #2 starboard cargo tank. Due to the size, barge can make repairs at next ISE.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 December 2022
Resolved 20 November 2019
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 20 November 2019 Resolved
Warning signs were heavily faded and you could not read them.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 November 2019
Resolved 20 November 2019
Resolution: Corrected prior to the end of the inspection
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 20 November 2019 Resolved
Containment under both cargo piping manifolds was full of product and not cleaned out.
Action required: 10 - Deficiency Rectified
Due 20 November 2019
Resolved 20 November 2019
Resolution: Cleaned out cargo contanment same day of inspection
Construction/Loadline › Hull › Side Shell
Issued 9 November 2014 Resolved
Barge authorized to transit to TT 237 Baton Rouge to offload and make permanent repairs. No additional cargo operations are authorized.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2014
Resolution: Barge arrived on a PTP w/ damage to the port bow head log and rake. Satisfactory repairs were made.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 3 March 2014 Resolved
Vessel rep was unable to demonstrate proper operation of high level/overfill alarms.
Action required: 705 - Other - as specified
Due 17 March 2014
Resolved 17 March 2014
Resolution: Tested overfill alarms. Test Sat.
Deck/Cargo › Cargo Heating › General
Issued 22 February 2010 Resolved
New steam lines not approved by MSC as required in 46 CFR 56.01-10. Vessel is restricted from carrying cargoes requiring steam lines to be used; other cargoes carried IAW COI as approved.
Action required: 705 - Other - as specified
Resolved 7 September 2010
Electrical › Electric Supply System (service) › Cable
Issued 2 October 2007 Resolved
Make permanent repairs to class 1/Div 1 electrical box for kim hotstart.
Condition: Improper/Lack of Maintenance
Due 5 November 2007
Resolved 5 November 2007
Resolution: Found correct.
Communications › Visual Communication › Warning Sign (gangway)
Issued 2 October 2007 Resolved
Renew faded warning sign.
Condition: Improper/Lack of Maintenance
Due 5 November 2007
Resolved 5 November 2007
Resolution: Found correct.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 2 October 2007 Resolved
Prove proper operation of emergency shut-down.
Condition: Improper/Lack of Maintenance
Due 5 November 2007
Resolved 5 November 2007
Resolution: Found correct.
Pollution Prevention/Response › Response Equipment › Non-sparking Hand Scoops/Shovels/Buckets
Issued 15 April 2005 Resolved
supply non-sparking shovel to spill kit
Condition: Unknown
Due 30 April 2005
Resolved 4 May 2005
Resolution: provided a non-sparking shovel in spill kit.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 15 April 2005 Resolved
label hoses "OIL SERVICE"
Due 30 April 2005
Resolved 4 May 2005
Resolution: Hoses were labled in white paint "OIL SERVICE"
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 15 April 2005 Resolved
make repairs to flange stud on vapor recovery piping
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 May 2005
Resolution: Removed vapor recovery valve and rewelded flang stud.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.