Documentation record
Registered dimensions (L × B × D)60.0 ft × 22.0 ft × 8.0 ft
Registered tonnagegross 88 / net 70
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULFGATE SHIPYARD INC · PORT ARTHUR, TX, UNITED STATES · built 1980
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeBox
Hull configurationMonohull
Hailing portVICKSBURG, MS
Endorsements, as the file codes themcw_un
DocumentationExpired · issued 30 June 2004
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it88 - Simplified, Gross Ton
70 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 27 inspections, each with its date, unit and type; 18 deficiencies with the resolution recorded against each, 2 without one; operational controls, none recorded without a removal date; 15 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 27
15 November 2023
Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7841360
9 October 2022
Damage Survey
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7574067
8 October 2022
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7604407
27 July 2022
Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7517810
27 July 2022
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7525023
22 July 2022
Initial Certification · Deficiency Check
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7513459
20 July 2022
Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7511251
18 May 2022
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7453619
9 April 2021
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7171906
5 April 2021
Damage Survey
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7169199
2 February 2021
Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7220712
23 July 2019
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6760563
16 February 2019
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6634128
16 December 2018
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6601605
1 June 2018
MTSA Verification · Industry Initiated Exam
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6457656
21 May 2018
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6431514
7 September 2011
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4140091
27 July 2011
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4096242
7 July 2011
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4072731
27 October 2010
Administration · Industry Initiated Exam · MTSA Verification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3879669
20 January 2009
Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3397046
3 January 2009
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3389710
7 July 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2704573
8 June 2006
MTSA Verification
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2674837
30 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1982241
10 December 1997
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 410911
26 December 1991
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 659071
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 October 2022
No resolution recorded
Machinery must be maintained to provide for safe operation of towing vessel under normal operating conditions. While the vessel was moored at Riverside Construction, the starboard generator crankcase exploded, causing a fire. The subsequent fire cause damage to the generator and surrounding wire cable runs. Owner to assess damage and submit repair proposal to MSD Vicksburg.
Action required: 60 - Rectify deficiencies prior to movement
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 9 October 2022
No resolution recorded
All bilges and void spaces shall be kept free from accumulation of combustible and flammable liquids insofar as practicable. The engine room bilges have an excessive amount of oil in them.
Action required: 60 - Rectify deficiencies prior to movement
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 July 2022
Resolved
A power driven vessel when pushing ahead or towing alongside shall exhibit two masthead lights in a vertical line. The vessel only has 1 masthead light and it is inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2022
Resolution: Operator installed new masthead light.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 22 July 2022
Resolved
All bilges and void spaces shall be kept free from accumulation of combustible and flammable liquids insofar as practicable. There is excessive oil in the engine room bilges. Remove prior to operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 July 2022
Resolution: Received receipt of oily water discharge from bilge to vac truck.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 22 July 2022
Resolved
Towing vessels must be equipped with an illuminated magnetic compass or an illuminated swing-meter (Western Rivers vessels only). The vessel currently does not have a magnetic compass or illuminated swing-meter.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 July 2022
Resolution: Operator installed new swing meter.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 22 July 2022
Resolved
The operator must ensure that the towing vessel is in compliance with Sub-chapter M at all times. Vessel suffered impact damage to an approximate 8 foot long section of railing on the 2nd deck forward on starboard side.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2022
Resolved 5 August 2022
Resolution: Operator replaced section of railing.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 22 July 2022
Resolved
Each towing vessel must have visible and audible alarms at the operating station for low hydraulic steering fluid levels. The vessel currently does not have an alarm at the operating station for low hydraulic steering fluid levels.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2022
Resolved 5 August 2022
Resolution: Operator installed float gauge for low level hydraulic alarm.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 22 July 2022
Resolved
Each towing vessel must be fitted with a general alarm in the engine room or any other area where background noise makes a general alarm hard to hear, a supplemental flashing red light with sign that reads: "Attention General Alarm- When Alarm Sounds or Flashes Go To Your Station." Vessels engine room does not have a flashing red light for the general alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2022
Resolved 5 August 2022
Resolution: Operator installed flashing red light in engine room for general alarm.
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 22 July 2022
Resolved
High bilge level alarm must be visible and audible at each operating station. The bilge alarm is currently inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2022
Resolved 5 August 2022
Resolution: Tested bilge alarm, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 22 July 2022
Resolved
Exposed hazard such as gears and rotating machinery must be protected by a cover, guard or rail. The two main engines and two generators on board do not have any guards for protection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2022
Resolved 5 August 2022
Resolution: Operator installed guards on the main engines and generators.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 July 2022
Resolved
A 40-B portable fire extinguisher must be located near the flammable or combustible storage room or cabinet. There is no portable extinguisher located near the paint locker on aft 2nd deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2022
Resolved 5 August 2022
Resolution: Portable fire extinguisher placed near paint lockers.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 July 2022
Resolved
A towing vessel on a rivers route must carry 3 day and 3 night visual distressed signals, which can be either red flares approved under 160.021 or 160.121 OR rocket propelled parachute flares approved under 160.036 or 160.136. Vessel does not have approved distress signals.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 August 2022
Resolution: New approved distress signals were purchased by operator.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 22 July 2022
Resolved
Means must be provided for closing each ventilation opening for machinery spaces. There is no way to close the ventilation intake or discharge for the engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2022
Resolved 5 August 2022
Resolution: Operator installed ventilation closure for engine room.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 July 2022
Resolved
Electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety or persons onboard. The engine room alarm panel junction box has no cover and has exposed wiring inside.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2022
Resolved 5 August 2022
Resolution: Operator installed new cover for alarm panel junction box.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 22 July 2022
Resolved
The employer shall provide an Employee Assistance Program (EAP) to include the display of informational mater, display of community service hot line telephone for crewmember assistance and display of employers policy regarding drug and alcohol use in the workplace. The vessel has no EAP information posted for crewmembers on the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2022
Resolved 5 August 2022
Resolution: EAP information posted in the galley area.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 July 2022
Resolved
Pressure vessels over 5 cubic feet volume and 15 psi MAWP must be equipped with one or more spring loaded relief valves the prevent pressure from exceeding the MAWP by more than 10%. The relief valve on the pressure vessel in the engine room has been painted and the tag is unreadable. Verify relief valve capacity of relief valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2022
Resolved 5 August 2022
Resolution: Verified relief valve setting is 200 psi, the same as the MAWP of the pressure vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 July 2022
Resolved
All owners and operators of an existing towing vessel must have onboard a valid COI prior to the specified phase-in period. This vessel has not scheduled an inspection or obtained a valid COI. The Vessel shall be made available for a Coast Guard COI inspection immediately and the vessel may no longer be permitted to operate.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 22 July 2022
Resolution: Completed initial COI inspection and issued temp COI to the vessel.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 5 April 2021
Resolved
Piping and tanks exposed to the outside of the hull must be made of metal and maintained in a leak free condition. During a fuel transfer, diesel fuel discharged into a naviagable waterway from a crack in the starboard fuel tank, which is connected to the hull.
A 2" x 10" doubler was welded over fracture as a temporary repair. Permanent repairs must be made at next drydock and prior to initial COI issuance due by 19JUL21 to the satisfaction of a CG Marine Inspector.
Action required: 705 - Other - as specified
Due 9 April 2021
Resolved 22 July 2022
Resolution: Verified permanent repairs were completed on the starboard fuel tank.