MAURY USCG vessel records
← All vessels

MM-47B

MM-47B is a 1999 tank barge. The Coast Guard has recorded 40 inspections since 1999, most recently in July 2026, along with 14 deficiencies and 3 casualty investigations between 2007 and 2017.

Records from 1999 to 2026. Most recent: inspection, 7 July 2026.

Built
1999
Last inspected
7 July 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 7 July 2026
…with no type recorded7
Operational controls None recorded without a removal date
Years with a record 27 calendar years (1999–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

489926
Flag
UNITED STATES
Maury page id
psix-489926

Documentation record

Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS · ASHLAND CITY, TN, UNITED STATES · built 1999
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 2 April 2026 · expires 30 April 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 13

Inspection history · 40

7 July 2026 Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8425935
25 June 2025 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8165985
3 May 2024 Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7906292
5 July 2023 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7733368
10 May 2022 Periodic Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7444838
24 June 2021 Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7232168
12 June 2020 Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6974662
26 March 2019 Drydock Exam · Cargo Tank Internal · Examination of Repairs · MTSA Verification · COI Inspection · Internal Structural Exam · Damage Survey
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6649705
14 June 2018 MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6443752
16 May 2017 MTSA Verification · Periodic Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6146323
15 January 2017 Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6072943
17 February 2016 MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5817139
8 April 2015 Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5106764
18 March 2014 Internal Structural Exam · MTSA Verification · Administrative Inspection · In-Service Inspection · Examination of Repairs · COI Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4818530
26 July 2013 Examination of Repairs · Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4665257
5 July 2013 Damage Survey
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4643506
5 July 2013 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4656954
7 June 2013 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4616156
6 June 2012 Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4334656
4 March 2010 Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3690031
2 August 2009 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3554507
4 March 2009 Cargo Tank Internal · Drydock Exam · Administrative Inspection · COI Inspection · MTSA Verification · Internal Structural Exam
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3427434
17 January 2008 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3134196
8 October 2007 Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3077729
22 June 2007 Annual Inspection
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2970255
1 February 2007 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2870737
15 October 2006 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2800981
10 April 2006 MTSA Verification · COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2611427
17 February 2005 Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2294694
12 April 2004 Internal Structural Exam · Annual Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 2042651
8 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1997390
22 August 2003 Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 1883987
20 August 2003 Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 1923098
4 April 2003 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1768056
4 March 2003 Periodic Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1749183
25 June 2002 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1630629
12 April 2001 COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1422045
27 March 2000 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1047888
23 April 1999 Administrative
Administrative · MSO Paducah · USCG Heartland District (CGD-H) · Activity 790759
16 April 1999 Initial Certification · Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1464167

Deficiency record · 14

03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 23 June 2020 Resolved
#04 port wing void forward hatch cover dogging ear bent. Repair or place hatch cover to the satisfaction of the attending Coast Guard marine inspector.
Action required: 10 - Deficiency Rectified
Due 23 June 2020
Resolved 23 June 2020
Resolution: Hatch cover replaced with new cover.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 8 April 2015 Resolved
Renew draft marks to contrast with hull.
Action required: 705 - Other - as specified
Resolved 13 April 2015
Resolution: Vessel rep had fore and aft draft marks renewed.
Deck/Cargo › Cargo Heating › General
Issued 8 April 2015 Resolved
Repair visual alarm on thermal fluid heater. Indicator did not actuate when an alarm had tripped.
Action required: 705 - Other - as specified
Resolved 8 April 2015
Resolution: Vessel rep replaced the indicator and proved proper operation.
Construction/Loadline › Hull › Hull Plating
Issued 5 July 2013 Resolved
The Port #4 void sustained significant damage to side shell and internals due to an allision with lock wall in Alton, IL (ST Louis area) Upon cargo off load in Baton Rouge, LA make permanent repairs as necessary and to the satisfaction of the attending Marine Inspector before next cargo loading operation.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 19 July 2013
Resolved 5 August 2013
Resolution: All damage was cropped and renewed to the satisfaction of the attending marine inspector.
Deck/Cargo › Cargo Heating › General
Issued 22 June 2007 Resolved
Alarms were tested and they shut down the thermal fluid heater but the alarm circuit failed to operate. Prove proper operation of alarm and strobe to the satisfaction of local attending CG Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 July 2007
Resolved 27 June 2007
Resolution: Repaired.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 10 April 2006 Resolved
One of three portable fire exinguishers did not have mounting bracket.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 May 2006
Resolved 23 May 2006
Resolution: Mounting bracket installed.
Deck/Cargo › Cargo Stowage › General
Issued 10 April 2006 Resolved
#4 ullage opening hatch wasted and unable to adequately support hatch gasket.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 May 2006
Resolved 23 May 2006
Resolution: Hatch gasket adequately supported.
Deck/Cargo › Cargo Stowage › General
Issued 10 April 2006 Resolved
Eleven valve position indicators on cargo transfer system inoperable.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 May 2006
Resolved 23 May 2006
Resolution: All valve position indicators verified as operable.
Stability › Watertight Integrity
Issued 22 August 2003 Resolved
Unknown condition of internal structure, 6-8" in-set to stbd, stern at knuckle. Unable to enter void during preliminary damage survey. Make vsl available for internal damage survey by CG Marine Inspector. No cargo ops until, necessary repairs (if any) are completed to satisfaction of attendng [name withheld]: Internal Structure
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 28 August 2003
Stability › Watertight Integrity
Issued 22 August 2003 Resolved
Properly repair stern stbd knuckle and surrounding damage. Conduct air test on stern void after repairs are conducted. LEGACY COMPONENT DESC: Damage
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 August 2003
Resolved 29 August 2003
Resolution: Inspected repairs and witnessed air test. All sat.
Electrical › Lighting (service)
Issued 4 March 2003 Resolved
Properly terminate exposed dead-end wires on bow outlet box LEGACY COMPONENT DESC: Outlet Box
Condition: Unknown
Due 4 March 2003
Resolved 4 March 2003
Resolution: dead end wires removed by vsl rep during inspection
Deck/Cargo › Mooring/Anchoring
Issued 4 March 2003 Resolved
Renew horn of aft starboard timberhead.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 April 2003
Resolved 25 March 2003
Construction/Loadline › Structures
Issued 4 March 2003 Resolved
Repair dogs/ears on port #2 & #4 void space hatches. LEGACY COMPONENT DESC: Manhole
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 April 2003
Resolved 25 March 2003
Stability › Watertight Integrity
Issued 25 June 2002 Resolved
Make permanent repairs to port #2 aft void space hatch hinge next time vessel is gas freed for any reason to the satisfaction of the attending marine inspector. LEGACY COMPONENT DESC: Hatch Cover
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 26 June 2002
Resolution: Replaced Port #2 aft wing void hatch cover at Mike''s Inc. Drydock Facility on 26 Jun 02.

Casualty record · 3

8 October 2007Routine · role: Involved in a Marine Casualty · activity 3077729
5 July 2013Routine · role: Involved in a Marine Casualty · 1 injured · activity 4656954
15 January 2017Routine · role: Involved in a Marine Casualty · activity 6072943
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.