Documentation record
Registered dimensions (L × B × D)52.8 ft × 22.0 ft × 7.5 ft
Registered tonnagegross 75 / net 51
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGREENVILLE · built 1982
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portST LOUIS, MO
Endorsements, as the file codes themcw_un
DocumentationValid · issued 6 July 2026 · expires 31 August 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it75 - Regulatory (Subpart C or D), Gross Ton
51 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 25 inspections, each with its date, unit and type; 19 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 41 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 25
24 November 2025
DAPI Audit
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8279225
22 September 2025
Annual Inspection · MTSA Verification · Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8228066
30 September 2024
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8004317
16 November 2023
Administrative Inspection · DAPI Audit
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7826098
22 September 2023
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7796713
11 August 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7530281
7 April 2021
Initial Certification · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7170710
19 January 2019
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6613220
7 March 2017
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6101440
15 July 2014
Industry Initiated Exam · Deficiency Check · MTSA Verification · Administration
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4923012
9 August 2013
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4683572
5 July 2013
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4656954
3 May 2013
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4585367
9 September 2011
Industry Initiated Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4138667
5 January 2007
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2850646
25 December 2006
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2849350
1 June 2006
MTSA Verification · Administrative Inspection · Uninspected Other
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2667118
22 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1968386
17 May 2001
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 124799
16 December 1999
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 435881
12 September 1997
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 412828
28 April 1996
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 53131
1 April 1993
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 357323
9 March 1993
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 356856
16 February 1988
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 321459
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 22 September 2025
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid. High pressure, fuel supply for starboard main diesel engine excessively leaking fuel. Deficiency to be corrected prior to operating engine and prior to vessel returning to commercial towing operation.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 October 2025
Resolution: High pressure fuel system delivery components (cylinder head delivery system fittings and most metalic tubing) replaced; engine operated with no observable active fuel leaks.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 September 2025
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Distribution panel located on engine room forward bulkhead is missing a blank exposing crew to a potential shock hazard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2025
Resolved 21 October 2025
Resolution: Blank installed in distribution panel.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 30 September 2024
Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces.
Port and Starboard side ventilation do not open and close as designed.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 October 2024
Resolution: Received videos of each side ventilation closures functioning properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 30 September 2024
Resolved
An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard or rail.
Port generator missing cover.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 October 2024
Resolution: Received a photo of new lagging placed over the generator manifold.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 September 2024
Resolved
Each towing vessel certificated under the provisions of this sub chapter must be in full compliance with the terms of the COI.
Rudder posts have play in them allowing water to come up on deck and make loud clanking when operating rudders. Operator is to come up with a plan to rectify issue due to dry dock not being until 2026 and present to the CG.
Action required: 705 - Other - as specified
Resolved 22 September 2025
Resolution: Witnessed proper operation of steering and flanking rudders.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 August 2022
Resolved
The fire detection system has not been serviced or maintained in accordance with the manufactures manual. Prove that the fire detection system is serviced and maintained annually.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 23 August 2022
Resolved 11 August 2022
Resolution: The deficiency was cleared to the satisfaction of an USCG Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 August 2022
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards. Both generator windings are dirty and oil soaked. Prove the windings have been cleaned to the satisfaction of a USCG Marine Inspector.
Due 18AUG2022.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 August 2022
Resolved 23 August 2022
Resolution: The deficiency was cleared to the satisfaction of a USCG Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 August 2022
Resolved
Machinery systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board. Two (02) steering hydraulic hoses located in the engine room are cracked, bulging and showing signs of severe corrosion. Replace both hoses to the satisfaction of the attending USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2022
Resolved 17 August 2022
Resolution: The deficiency was cleared to the satisfaction of an attending USCG Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 August 2022
Resolved
The engine room fuel tank is fitted with a primary fuel shutoff for all machinery. Prove the secondary emergency fuel shutoffs work for all engines.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 August 2022
Resolved 17 August 2022
Resolution: The deficiency was cleared to the satisfaction of an attending USCG Marine Inspector.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 8 July 2021
Resolved
Prove proper operation of the engine room general alarm prior to operations.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 July 2021
Resolution: The deficiency was cleared to the satisfaction of a USCG Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 July 2021
Resolved
Secure semi portable fire extinguisher.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2021
Resolved 9 July 2021
Resolution: The deficiency was cleared to the satisfaction of a USCG Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 8 July 2021
Resolved
Prove the secondary port engine emergency fuel shutoff operates properly.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2021
Resolved 3 August 2021
Resolution: The deficiency was cleared to the satisfaction of a USCG Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 8 July 2021
Resolved
Install and prove means to stop engine room fans.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2021
Resolved 3 August 2021
Resolution: The deficiency was cleared to the satisfaction of a USCG Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 7 April 2021
Resolved
Clean both oil covered generator windings.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2021
Resolved 23 August 2021
Resolution: The deficiency was cleared to the satisfaction of an attending USCG Marine Inspector.
Documentation
Issued 9 March 1993
Resolved
DOCUMENTATION CERTIFICATE NOT ONBOARD VESSEL.
Condition: Unknown
Due 1 April 1993
Resolved 1 April 1993
Navigation
Issued 9 March 1993
Resolved
COPY OF INLAND NAVIGATION RULES NOT ONBOARD VESSEL.
Condition: Unknown
Due 1 April 1993
Resolved 1 April 1993
Accommodation/Occupational Safety
Issued 9 March 1993
Resolved
NO MARPOL PLACARD ON BOARD VESSEL.
Condition: Unknown
Due 1 April 1993
Resolved 1 April 1993
Fire Fighting
Issued 9 March 1993
Resolved
MINIMUM NO. OF PORTABLE FIRE EXTINGUISHERS (2) NOT ON BOARD. ONLY ONE ON BOARD.
Condition: Unknown
Due 1 April 1993
Resolved 1 April 1993
Fire Fighting
Issued 9 March 1993
Resolved
MINIMUM NO. OF TYPE B-II FIRE EXTINGUISHER (2) NOT IN ENGINE ROOM. ONLY ONE IN ENGINE ROOM.
Condition: Unknown
Due 1 April 1993
Resolved 1 April 1993