MAURY USCG vessel records
← All vessels

EBS 14

Built
2014
Last inspected
7 January 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 7 January 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2015–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1250140
Flag
UNITED STATES
Maury page id
psix-1250140

Documentation record

Registered dimensions (L × B × D)160.0 ft × 40.0 ft × 8.7 ft
Registered tonnagegross 467 / net 467
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJAMES BUILT LLC · CALVERT CITY, KY, UNITED STATES · built 2014
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portMEMPHIS, TN
Endorsements, as the file codes themcw_un
DocumentationValid · issued 2 June 2026 · expires 31 July 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it467 - Simplified, Net Ton
467 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 13 inspections, each with its date, unit and type; 5 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 24 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 24

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CE-58 Tank Barge · MISLE 41049 · 7 March 2017 · activity 6101440MGI-F3 Tank Barge · MISLE 45685 · 7 March 2017 · activity 6101440MIDSTREAM FUELER 17 Tank Barge · MISLE 53382 · 7 March 2017 · activity 6101440FUELER NO. 3 Tank Barge · MISLE 54715 · 7 March 2017 · activity 6101440BILLIE D MILLER Towing Vessel · MISLE 72980 · 7 March 2017 · activity 6101440DENNY ANGEL Towing Vessel · MISLE 78107 · 7 March 2017 · activity 6101440MTC 103B Freight Barge · MISLE 83752 · 7 March 2017 · activity 6101440AGS 667B Freight Barge · MISLE 122480 · 7 March 2017 · activity 6101440TOM ZUPAN Towing Vessel · MISLE 130686 · 7 March 2017 · activity 6101440VL 7755 Freight Barge · MISLE 148512 · 7 March 2017 · activity 6101440VL 81231 Freight Barge · MISLE 190667 · 7 March 2017 · activity 6101440RAYMOND GRANT ECKSTEIN Towing Vessel · MISLE 195098 · 7 March 2017 · activity 6101440CHUB MORRIS Towing Vessel · MISLE 205635 · 7 March 2017 · activity 6101440MM 57B Tank Barge · MISLE 560944 · 7 March 2017 · activity 6101440SCF 2566 B Freight Barge · MISLE 726021 · 7 March 2017 · activity 6101440SCF 2565 B Freight Barge · MISLE 726022 · 7 March 2017 · activity 6101440SCF 2572B Freight Barge · MISLE 743320 · 7 March 2017 · activity 6101440WOOD RIVER CREWBOAT Passenger (Uninspected) · MISLE 991339 · 7 March 2017 · activity 6101440ESRT 102 Freight Barge · MISLE 1033850 · 7 March 2017 · activity 6101440ESRT 201 B Freight Barge · MISLE 1033851 · 7 March 2017 · activity 6101440EBS 11 Tank Barge · MISLE 1048522 · 7 March 2017 · activity 6101440AO&R 235 Industrial Vessel · MISLE 1441407 · 7 March 2017 · activity 6101440MTC 6351 Freight Barge · MISLE 1441408 · 7 March 2017 · activity 6101440JEM 360 Freight Barge · MISLE 1441413 · 7 March 2017 · activity 6101440

Inspection history · 13

7 January 2025 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8059491
17 April 2024 Drydock Exam · COI Inspection · Administrative Inspection · Internal Structural Exam · Cargo Tank Internal
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7896821
10 January 2024 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7851831
22 September 2023 Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7796711
11 August 2022 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7530258
10 August 2021 Periodic Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7272755
16 July 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7007952
30 July 2019 Internal Structural Exam · MTSA Verification · COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6767348
23 August 2018 MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6517725
22 August 2017 Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6243900
7 March 2017 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6101440
25 July 2016 Administrative Inspection · Periodic Inspection · MTSA/ISPS Verification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5940535
26 June 2015 Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5164247

Deficiency record · 5

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 January 2025 Resolved
The following plans, if applicable to the particular vessel, must be submitted for Coast Guard review in accordance with § 110.25-3: (a)Elementary one-line wiring diagram... Plan submitted to fulfill this requirement: Marine Solutions Dwg. No. 051301EL-1(Rev0): Electrical Arrangement (1Sht) The plan has not been approved and as of this date the status of the plan remains the same as stated in letter dated 11/20/2013, Serial E2-1303955, "Returned for Revision". The outstanding requirement as noted in letter, "Ground detection system is not shown on the drawing per 46 CFR 111.05-21." Re-submit referenced plan with required revision for MSC approval.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 January 2025
Resolution: Required plan submitted for MSC approval this date.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 17 April 2024 Resolved
Cargo pump relief valves shall be tested at least once each year to determine that they function satisfactorily at the pressure at which they are set to open. Set seal was found broken on cargo pump relief valve, and setting appeared to have been altered. Prove the relief valve is set to the correct pressure relief setting and reseal.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2024
Resolved 1 July 2024
Resolution: Received report attesting to the cargo pump relief valve being satisfactorily tested at it set pressure of 125psi at the last annual testing.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 11 August 2022 Resolved
Barge cargo hose #10 was cracked and showing signs of bulging due to the braided wire rusting. Remove hose from service and replace with new.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2022
Resolved 11 August 2022
Resolution: The deficiency was cleared to the satisfaction of an USCG Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 August 2019 Resolved
Install shut off valve in cargo pump engine fuel supply line.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2019
Resolved 20 August 2019
Resolution: Valve installed as required.
Electrical › Electric Supply System (service) › Cable
Issued 22 August 2017 Resolved
Unapproved use of temporary flexible cord (extension cord) used in lieu of fixed wiring for permanent circuit and receptacle. NFPA NEC 400.8(1), incorporated by 46 CFR 111.60-13(b)(1), prohibits flexible cord as a substitute for fixed wiring. Extension cord installed from ship service generator through overhead race to provide a receptacle at crew work station.
Action required: 705 - Other - as specified
Due 22 August 2017
Resolved 22 August 2017
Resolution: Temporary flexible cord removed from vessel.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.