Inspection history · 54
7 March 2017
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6101440
9 January 2015
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5050880
27 August 2014
Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4966842
20 June 2014
Administrative Inspection · Periodic Inspection · MTSA Verification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4894465
29 July 2013
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4668516
25 June 2013
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4631026
12 October 2012
Annual Inspection · Administrative Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4466758
19 July 2011
Internal Structural Exam · Cargo Tank Internal · Drydock Exam · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4097149
19 July 2010
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3787375
22 September 2009
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3604572
22 June 2009
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3510683
18 July 2008
MTSA Verification · Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3247932
19 March 2008
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3167763
24 July 2007
MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2976368
5 May 2006
Hull Examination · Administrative Inspection · COI Inspection · MTSA Verification · Cargo Tank Internal
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2641723
10 March 2005
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2307301
15 February 2005
MTSA Verification · Annual Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2286842
17 May 2004
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2070644
22 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1968392
15 May 2003
Periodic Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1791695
3 July 2002
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1640267
12 May 2001
Hull Examination · COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1405210
12 June 2000
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1412116
12 May 1999
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1471863
5 May 1998
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1470443
22 May 1997
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1108307
16 May 1997
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1392683
24 May 1996
Re-Inspection · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1442397
26 May 1995
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 872617
26 January 1995
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 657097
9 November 1994
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 508337
10 August 1994
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 531100
23 May 1994
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1018763
28 May 1993
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 825893
30 June 1992
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1256760
15 January 1992
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1265590
12 December 1991
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 657094
5 December 1991
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 657098
1 November 1991
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1248123
23 October 1991
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1244821
17 July 1991
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 939586
4 June 1991
Hull Examination · COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1233824
10 May 1990
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 916470
8 May 1990
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 917197
14 March 1990
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 915855
21 June 1989
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1199645
2 November 1988
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 890787
13 July 1988
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 897996
12 May 1988
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1195456
12 February 1988
MARPOL Annex II Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1021086
16 October 1987
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1322296
10 June 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1314290
5 May 1986
COI Inspection · Credit Drydock
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1001188
9 May 1985
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1289276
Electrical › Electrical Distribution System (service) › Cable
Issued 27 August 2014
Resolved
Propose method to comply with Class I/Div I electrical requirements for vessels that carry Grade D cargos.
Action required: 705 - Other - as specified
Due 27 September 2014
Resolved 27 August 2014
Resolution: O/O requested COI ammendment to carry Grade E cargo.
Electrical › Electric Generation Source (service) › Generator
Issued 12 October 2012
Resolved
Generator would not supply power.
Action required: 705 - Other - as specified
Due 12 November 2012
Resolved 5 November 2012
Resolution: Replaced relay from generator to main power panel
Deck/Cargo › Cargo Transfer (solid) › General
Issued 12 October 2012
Resolved
Found 2" nipple in cargo transfer line. Nipple was not welded.
Action required: 705 - Other - as specified
Due 12 November 2012
Resolved 5 November 2012
Resolution: Replaced threaded pipe nipple. Welded steel coupling in elbow.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Gaskets
Issued 19 July 2010
Resolved
Properly replace hatch gaskets on bow & stern voids and #3 starboard hatches.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 July 2010
Resolved 27 July 2010
Resolution: The bow, stern, and #3 starboard void hatch cover gaskets were replaced.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 18 July 2008
No resolution recorded
Transfer hose #1 had major kink in hose with abrassions in outer reinforcement and a possible leak.
Condition: Unknown
Due 18 July 2008 — due date passed with no resolution recorded
Resolution: The kinked section of the hose was removed and the hose was repaired and tested to 1.5 MAWP.
Electrical › Electric Generation Source (service) › Generator
Issued 18 July 2008
No resolution recorded
missing RPM gage for prime mover on generator
Due 18 July 2008 — due date passed with no resolution recorded
Resolution: Installed new gage parts receipt provided to CG.
Engineering › Fuel Oil Service System › Hose
Issued 19 March 2008
No resolution recorded
Prime mover fuel hose does not meet SAE J-1942 rating.
Action required: 705 - Other - as specified
Due 19 April 2008 — due date passed with no resolution recorded
Resolution: Prime mover fuel hoses have been replaced with the following qualified SAE J-1942 hoses:
Gates Rubber Co. Hose #: 6C5M 5/16 ID
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 15 February 2005
Resolved
Properly update transfer procedures to include internal cargo tanks
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 February 2005
Resolved 9 March 2005
Electrical
Issued 16 May 1997
Resolved
Properly secure electric cable for port outside light.
Condition: Unknown
Due 23 May 1997
Resolved 30 May 1997
Deck/Cargo
Issued 16 May 1997
Resolved
Replace flame screens on three goose neck vents on lube oil system.
Condition: Unknown
Due 23 May 1997
Resolved 30 May 1997
Deck/Cargo
Issued 24 May 1996
Resolved
PROVIDE GUARD FOR EXHAUST IWO DIESEL GENERATOR.
Condition: Unknown
Due 27 June 1996
Resolved 27 June 1996
Engineering
Issued 24 May 1996
Resolved
REPLACE VALVE HANDLE IWO DIESEL FUEL DECK TANK.
Condition: Unknown
Due 27 June 1996
Resolved 27 June 1996
Deck/Cargo
Issued 4 June 1991
Resolved
RENEW CARGO TANK WARNING SIGNS AND REPAINT RED PENNANT.
Condition: Unknown
Due 4 June 1991
Resolved 4 June 1991
Construction/Loadline
Issued 4 June 1991
Resolved
WELD FROM INSIDE CARGO TANK PENETRATIONS AS FOLLOWS: (a). 8 IN EACH LUBE OIL TANK, (b). 10 IN PORT #1, (c). 8 IN STBD #1, (d). 10 IN PORT #2, (e). 5 IN STBD #2, (f). 7 IN PORT #3, (g). 11 IN STBD #3.
Condition: Unknown
Due 4 June 1991
Resolved 4 June 1991
Construction/Loadline
Issued 4 June 1991
Resolved
CROP AND RENEW APPROXIMATELY 18" X 36" UPPER OUTBOARD AFT BULKHEAD, IN WAY #2 PORT CARGO TANK, AS MARKED.
Condition: Unknown
Due 4 June 1991
Resolved 4 June 1991
Construction/Loadline
Issued 4 June 1991
Resolved
MAKE PERMANENT REPAIR FROM INSIDE TO FRACTURES, HEADLOG WRAPPER STARBOARD SIDE.
Condition: Unknown
Due 4 June 1991
Resolved 4 June 1991
Documentation
Issued 4 June 1991
Resolved
PRIOR TO OPERATION OF THE VESSEL PROVIDE ON BOARD CURRENT CERTIFICATE OF FININCIAL RESPONSIBILITY.
Condition: Unknown
Due 4 June 1991
Resolved 4 June 1991
Construction/Loadline
Issued 4 June 1991
Resolved
WELD APPROXIMATELY 18 PICK-UPS AS MARKED IN FORWARD RAKE, HEADLOG VERTICALSAND UPPER END OF BOTTOM LONGITUDINALS.
Condition: Unknown
Due 4 June 1991
Resolved 4 June 1991
Construction/Loadline
Issued 8 May 1990
Resolved
MAKE AND MAINTAIN TEMPORARY REPAIR TO 6" FRACTURE AT THE DECK KNUCKLE 6' AFT OF CAVEL OR STARBOARD SIDE FORWARD. PERMANENT REPAIRS TO BE MADE BY 05MAY91.
Condition: Unknown
Due 8 May 1990
Resolved 8 May 1990
Documentation
Issued 12 May 1988
Resolved
PROVIDE CERTIFICATE OF FINANCIAL RESPONSIBILITY PRIOR TO RELOADING BARGE BUT NOT LATER THAN 15JUN88.
Condition: Unknown
Due 12 May 1988
Resolved 12 May 1988
Deck/Cargo
Issued 12 May 1988
Resolved
TEST CARGO TRANSFER PIPING TO 225 PSI PRIOR TO RELOADING BARGE BUT NOT LATER THAN 15JUN88.
Condition: Unknown
Due 12 May 1988
Resolved 12 May 1988
Electrical
Issued 12 May 1988
Resolved
PROVIDE OVERSPEED TRIP ON GENERATOR PRIME MOVER NOT LATER THAN 15JUN88.
Condition: Unknown
Due 12 May 1988
Resolved 12 May 1988
Unknown
Issued 10 June 1987
Resolved
REPAIR ELECTRICAL INSTALLATIONS TO COMPLY WITH 46 CFR 111.105-31(K).
Condition: Unknown
Due 10 June 1987
Resolved 10 June 1987
Unknown
Issued 10 June 1987
Resolved
PROVIDE USCG INSPECTOR WITH CURRENT CERTIFIED FMC CERTIFICATE REFLECTING CORRECT OPERATOR.
Condition: Unknown
Due 10 June 1987
Resolved 10 June 1987
Unknown
Issued 10 June 1987
Resolved
OBTAIN AND PROVIDE TO USCG INSPECTOR, ORIGINAL COI OR A COPY CERTIFIED TO BE TRUE BY THE USCG.
Condition: Unknown
Due 10 June 1987
Resolved 10 June 1987
Unknown
Issued 10 June 1987
Resolved
PROVIDE USCG INSPECTOR WITH USCG APPROVED PLAN FOR INSTALLED SLOP TANK.
Condition: Unknown
Due 10 June 1987
Resolved 10 June 1987