Records from 1993 to 2026. Most recent: inspection, 24 March 2026.
Documentation record
Registered dimensions (L × B × D)48.3 ft × 19.9 ft × 6.0 ft
Registered tonnagegross 48 / net 32
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · OAKVILLE · built 1957
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 6 July 2026 · expires 31 August 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it48 - Regulatory (Subpart C or D), Gross Ton
32 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 15
24 March 2026
Administrative Inspection · Vessel Attendance
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8323107
23 July 2025
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8185848
23 October 2024
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8014040
28 July 2023
COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7753797
5 July 2023
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7733940
17 March 2022
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7401864
17 March 2021
Initial Certification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7115598
7 March 2017
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6101440
23 June 2016
Deficiency Check · MTSA Verification · Industry Initiated Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5916825
14 January 2014
Administration
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4782824
13 December 2008
Administration
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3379297
18 December 2006
Uninspected Other · MTSA Verification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2842783
22 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1968388
16 December 1999
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 435859
9 March 1993
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 356855
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 13 May 2026
No resolution recorded
A vessel that is exposed to salt water not more than 6 months in any 12-month period since initial certification must undergo a drydock (DD) and internal structural (IS) examination at least once every 5 years. IAW the vessel's COI, USCG Marine Inspector credit for DD & IS exams was required by 3/31/2026. Vessel attended by marine inspectors on 3/24/2026; however, repairs noted on that date and noted in Surveyor's report dated 3/23/2026 have not been verified as being completed. Required repairs include:
1. Steering gear, leaks, plating, & bearings repairs
2. Potable water tank sediment
3. Void bulkhead repairs
4. Railing repairs
5. Internal structural frame repairs
6. Hull plating, appendages, & weld seam repairs
7. Superstructure repairs
8. Provide hull gauging report (referenced in Surveyor's
notes)
(Detailed list of repairs provided to vessel rep.)
Credit for IS/DD exams not received by due date.
Code 705: Correct above prior to conducting operations which requires a certificate of inspection.
Action required: 705 - Other - as specified
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 23 October 2024
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided:(6) Low hydraulic steering fluid levels,(b) Alarms must:(1) Be visible and audible at each operating station.
During annual inspection it was noted that the Audible alarm for low hydraulic level was inoperable on Port Pump.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 October 2024
Resolution: received video evidence of proper operation of audible alarm.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 28 July 2023
Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Noted crack on handrails iwo stbd quarter.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2023
Resolved 28 August 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 July 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Noted exhaust leaks on inboard exhaust of both MDE.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2023
Resolved 28 August 2023
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 July 2023
Resolved
A towing vessel subject to this sub-chapter and choosing the Coast Guard inspection option, or required to have the Coast Guard inspection option, must undergo an annual inspection within 3 months before or after the COI anniversary date. The annual inspection was not completed during the six month window and the COI has lapsed. Submit a CG-3752 for renewal COI inspection prior to towing and or commercial service.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2023
Resolution: VSL completed COI inspection
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 17 March 2022
Resolved
An exposed hazard such as rotating machinery must be protected by a cover, guard or rail. Both engine room main propulsion shafts are exposed causing a hazard. Install a cover, guard or rail to protect against such hazards.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2022
Resolved 30 June 2022
Resolution: The deficiency was cleared to the satisfaction of an attending USCG Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 17 March 2022
Resolved
An exposed hazard such as rotating machinery must be protected by a cover, guard or rail. Both main engine vibration dampers are exposed causing a hazard. Install a cover, guard or rail to protect against such hazards.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2022
Resolved 30 June 2022
Resolution: The deficiency was cleared to the satisfaction of an attending USCG Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 March 2022
Resolved
The owner and managing operator must ensure that the towing vessel is in compliance with this sub-chapter and other applicable laws and regulations at all times. The aft steering ram has a leak with a bucket in place to catch the hydraulic oil. Replace or repair the steering ram leak.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2022
Resolved 30 June 2022
Resolution: The deficiency was cleared to the satisfaction of an attending USCG Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 March 2022
Resolved
Main engine and auxiliary machinery must be equipped with gauges in the machinery space. The port main engine RPM gauge is inoperative. Replace or repair the gauge and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 March 2022
Resolved 30 June 2022
Resolution: The deficiency was cleared to the satisfaction of an attending USCG Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 March 2022
Resolved
Personnel dispatched from the vessel or that are working in an area on the exterior of the vessel without rails and guards must wear a life jacket meeting the requirements in 46 CFR 141.340 or a work vest approved by the Commandant under 46 CFR 160.053. Vessel's crew were wearing TYPE III life jackets that don't meet the requirements outlined in 46 CFR Sub-chapter M. Prove to the attending USCG Marine Inspector that all crew are wearing the proper approved life jackets.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2022
Resolved 30 June 2022
Resolution: The deficiency was cleared to the satisfaction of an attending USCG Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 March 2022
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford protection against hazards. The starboard generator return fuel line was leaking. The vessel's crew tightened the fuel line union fitting. The deficiency was corrected on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 March 2022
Resolved 30 June 2022
Resolution: The deficiency was cleared to the satisfaction of an attending USCG Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 March 2021
Resolved
The vessels fire detection panel has a auxiliary strobe light mounted in the pilothouse potentially causing a hazardous situation either blinding the Master and/or the audio alarm noise level preventing clear communications during an emergency. Remove strobe light and any electrical hazards preventing shock.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2021
Resolved 18 March 2021
Resolution: Cleared to the satisfaction of a CG Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 March 2021
Resolved
Vessel is certificated to carry 08 people total. During initial COI inspection the vessel only has 04 life jackets on board. Provide an additional 04 type 1 life jackets. Vessel is restricted to carrying 04 (total) people on board until all type 1 life jackets are on board and in service in accordance with 46 CFR 141.340
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2021
Resolved 18 March 2021
Resolution: Cleared to the satisfaction of a CG Marine inspector.