SUN FIGHTER

SUN FIGHTER is a 1978 passenger vessel (inspected). The Coast Guard has recorded 23 inspections since 2016, most recently in April 2026, along with 38 deficiencies and 3 casualty investigations between 2010 and 2019.

Records from 2010 to 2026. Most recent: inspection, 30 April 2026.

Built
1978
Last inspected
30 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 30 April 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WYB6722
Flag
UNITED STATES
Maury page id
psix-49782

Documentation record

Registered dimensions (L × B × D)61.3 ft × 17.0 ft × 7.7 ft
Registered tonnagegross 54 / net 36
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY-CRAFT, INC. · LOREAUVILLE, LA, UNITED STATES · built 1978
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBURAS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 21 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it54 - Regulatory (Subpart C or D), Gross Ton
36 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 23

30 April 2026 Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8332924
15 April 2025 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8123562
26 March 2025 Internal Structural Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8099851
3 April 2024 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7889319
16 January 2024 COI Inspection · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7849745
1 February 2023 Deficiency Check · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7630578
15 April 2022 Internal Structural Exam · Annual Inspection · Deficiency Check · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7420550
2 December 2021 Damage Survey
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7363502
26 November 2021 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7362109
9 March 2021 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7144953
21 February 2020 Internal Structural Exam · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6913120
6 January 2020 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6883309
17 September 2019 Deficiency Check · Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6814284
12 September 2019 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6827364
10 April 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6660033
22 January 2019 COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6610539
23 October 2018 In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6567221
11 June 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6440851
7 June 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6442354
9 April 2018 Drydock Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6385834
27 January 2017 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6075233
7 April 2016 Internal Structural Exam · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5846690
15 January 2016 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5798438

Deficiency record · 38

02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 22 April 2025 Resolved
All vessels except non-self-propelled vessels shall be provided with suitable steering apparatus. MI observed the vessel's hydraulic steering ram leaking steering fluid at an approximate rate of 50 drips per minute. The leakage is active and substantial enough to degrade the performance and reliability of the steering system. 46CFR 182.30-1(a)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 April 2025
Resolution: Vessel provided video proof of newly installed steering ram working properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 22 January 2024 Resolved
Gauges to indicate engine cooling water discharge temperature and lubricating oil pressure shall be provided for all propulsion engines and located so to be in view of the operator. The starboard main engine cooling water gauge was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2024
Resolved 5 February 2024
Resolution: Verified proper operation of starboard main engine cooling water gauge.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 22 January 2024 Resolved
Vessel must comply with applicable requirements for any radio installation. MF/SSB radio installation on board vessel does not have Digital Selective Calling (DSC) capability IAW 47 CFR 80.905(a)(2). Vessel is restricted from operating more than 20 nm from shore until a MF-DSC transmitter and receiver is installed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 April 2024
Resolved 19 February 2024
Resolution: Received third party report attesting to installation of MF/HF DSC transmitter/receiver.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 16 January 2024 Resolved
Each survival craft on a vessel must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway. The starboard life float was in disrepair with significant wastage to the webbing attaching the grab lines to the body of the life float. Deficiency rectified prior to departure; vessel procured new life float prior to completion of inspection.
Action required: 10 - Deficiency Rectified
Due 22 January 2024
Resolved 22 January 2024
Resolution: Deficiency rectified prior to departure; vessel procured new life float prior to completion of inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 January 2024 Resolved
All cable and wire must be installed with metal supports spaced not more than 24" apart, and in such a manner as to avoid chafing and other damage. The use of plastic tie wraps must be limited to bundling or retention of multiple cable installations. Multiple cable runs throughout the engine room were hanging loose and minimally secured by plastic zip ties.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2024
Resolved 5 February 2024
Resolution: Verified proper securing of cables and wiring throughout engine room.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 16 January 2024 Resolved
Shutoff valves shall be fitted in the fuel supply lines and shall be operable from outside the tank compartment. The shutoff valve for the aft fuel tank was inoperable. Prior to completion of the inspection, the operator was able to troubleshoot and inspector witnessed proper remote operation of the valve.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 22 January 2024
Resolved 22 January 2024
Resolution: operator was able to troubleshoot and inspector witnessed proper remote operation of the valve.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 February 2023 Resolved
All vessels except non-self-propelled vessels shall be provided with suitable steering apparatus. MI observed hydraulic leaks in the steering system to include engine driven pump housing and associated piping from the pump to the steering ram. Operator to repair all leaks to the satisfaction of the attending MI. 46CFR182.30-1 60c.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 14 February 2023
Resolved 23 February 2023
Resolution: Attending MI witnessed successful test of Ships steering system with no hydraulic leaks.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 14 February 2023 Resolved
It shall be the duty of the master of any vessel to assure that all exposed hatches are properly secured before getting underway for a voyage on other than protected waters. MI observed that both main engine hatch covers and engine room entry hatch, in addition to steering gear space hatch cannot be secured due to failed/missing hardware. Operator to replace and or repair to the satisfaction of the attending MI. 46CFR185.20-15 60c.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 14 February 2023
Resolved 23 February 2023
Resolution: Witnessed proper operation of both engine room hatch covers and lazarette.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 14 February 2023 Resolved
Examine all accessible parts of the exterior and interior of the hull, watertight bulkheads: MI observed multiple unsealed bulkhead penetrations on the forward engine room bulkhead. Operator to reseal penetrations to the satisfaction of the attending MI. 46CFR176.25-5 16c.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2023
Resolved 23 February 2023
Resolution: Witnessed proper resealing of bulkhead penetrations in fwd engine room bulkhead.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 February 2023 Resolved
Protective gratings shall be provided at such locations where persons or gear might come in contact with the exhaust pipe. MI observed exhaust lagging not properly installed and secured on both main propulsion engines and generator. Operator to reinstall or replace exhaust lagging to the satisfaction of the attending MI 46CFR182.15-20 16c.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2023
Resolved 23 February 2023
Resolution: Witnessed proper reinstallation of exhaust lagging.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 14 February 2023 Resolved
Examine all accessible parts of the exterior and interior of the hull, watertight bulkheads: MI observed a cracked weld aft of the port main propulsion engine and a gouged/cut weld in the vertical seam below the failed weld. Operator to make repairs to the satisfaction of the attending MI 46CFR176.25-5 16c.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2023
Resolved 23 February 2023
Resolution: Witnessed proper rewelding of fractured weld and gouge in bulkhead.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 14 February 2023 Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment that will result in a vessel that is reasonably safe from fire caused by and/or originating in electrical equipment, and reasonably safe from electrical shock of personnel. MI observed multiple dead ended wires, exposed conductors, improperly secured connectors and, unlabeled disconnects. Operator is required to remove all abandoned cable and wiring, secure wire connections, and label electrical disconnects and panels as cited in this reference to the satisfaction of the MI. 46CFR183.01-5 16c.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2023
Resolved 23 February 2023
Resolution: Verified removal of dead ended wires and exposed conductors.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 February 2023 Resolved
Protection from mechanical damage shall be specially considered. Unsupported piping in regards to the bilge pump riser in the vicinity of the port main propulsion engine was noted by the [name withheld] to properly secure all loose piping. 46CFR182.40-1 16c.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2023
Resolved 23 February 2023
Resolution: Verified proper securing for bilge piping.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 February 2023 Resolved
The fixed power bilge pump shall be self-priming and may be driven off the main engine or other source of power. MI observed the electrically powered bilge pump housing dripping from the pump case while pump was secured. Operator to identify the source of the leak and make necessary repairs to the satisfaction of the MI. 46CFR182.25-5 16c.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2023
Resolved 23 February 2023
Resolution: Verified proper operation of bilge pump with no leaks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 February 2023 Resolved
Engine control mechanisms. Such mechanisms shall be tested by operation and examined, visually, through-out their length. MI observed port main propulsion engine transmission control cable severely chaffed due to contact with the engine driven bilge pump belt. Operator to replace cable and reroute to avoid future damage. 46CFR176.25-10 16c.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2023
Resolved 23 February 2023
Resolution: Cable was replaced and rerouted to avoid future damage.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 February 2023 Resolved
Batteries shall be located as high above the bilge as practicable and secured against shifting with motion of the boat. MI observed engine room batteries not secured. Operator to secure batteries to the satisfaction of the attending MI. 46CFR183.05-20 16c.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2023
Resolved 23 February 2023
Resolution: Verified proper securing of ships batteries.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 14 February 2023 Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. MI observed generator guard not installed satisfactorily. Operator to reinstall guard to the satisfaction of the attending MI. 46CFR177.35-15 16c.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2023
Resolved 23 February 2023
Resolution: Witnessed reinstallation of guard on generator.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 February 2023 Resolved
All vessels shall be provided with an approved adult type life preserver for each person carried. Vessel is certified for 30 life preservers and was missing 02. Add two approved adult life preservers to the satisfaction of attending MI. 46 CFR 180.25-5
Action required: 60 - Rectify deficiencies prior to movement
Due 14 February 2023
Resolved 23 February 2023
Resolution: Witnessed addition of 02 life jackets on board.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 14 February 2023 Resolved
Except as further modified in this section, where items of life-saving equipment is not required, but are installed, such equipment and its installation shall meet the requirements of this part. Vessel has rescue platform and did not have a harness. Provide a harness and a means of securing the rescue platform to the vessel to the satisfaction of the MI. 46 CFR 180.05-5
Action required: 60 - Rectify deficiencies prior to movement
Due 14 February 2023
Resolved 25 April 2023
Resolution: harness was added on board and platform is now able to be secured to the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 14 February 2023 Resolved
The life line shall be of a size and strength not less than 3/8-inch diameter. Life line has began to deteriorate. Replace life lines on life floats to the satisfaction of the attending MI. 46 CFR 180.15-5
Action required: 60 - Rectify deficiencies prior to movement
Due 14 February 2023
Resolved 23 February 2023
Resolution: Verified renewal of grab lines on lift float.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 14 February 2023 Resolved
The inspection shall be such as to insure that the arrangement, materials and scantlings of the structure. Starboard window on pilot house was broken. Replace starboard window to the satisfaction of attending MI. 46 CFR 176.05-5
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 14 February 2023
Resolved 13 March 2023
Resolution: Window replaced and sealed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 February 2023 Resolved
Interconnected detection and alarm system. (a) An interconnected detection and alarm system must: (1) Consist of multiple-station smoke detectors listed by an NRTL, or independent laboratory accepted by the Commandant according to 46 CFR subpart 159.010, as meeting UL 217 (incorporated by reference, see 46 CFR 175.600); (2) Be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas required by 46 CFR 181.405(c) or 118.400(d) to be protected by the interconnected detection and alarm system; (3) Contain an independent power source; and (4) Alarm on low power. All vessels regulated by Subchapter T (this includes OSV-T boats) that have overnight accommodations for passengers or are operating on a Coastwise or Oceans route must have an interconnected detection and alarm system that complies with 46 CFR 181.450. Provide to the satisfaction of the attending MI. 46 CFR 181.450
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2023
Resolved 25 April 2023
Resolution: new fire detection was added to meet new final rule. Tested new detection, test sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 May 2022 Resolved
Accessories, such as switches, fuses, and sockets shall be standard National Electrical Code types for the loads to be carried. The 12V system on the vessel was malfunctioning causing VHF radios, AIS, radars, engine room smoke detection system, and ship whistle to be inoperable. 46 CFR 183.05-35
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 May 2022
Resolution: Vessel rep discovered faulty wiring from 12VDC fuse box to starboard battery bank. Rep replaced wire in kind.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 May 2022 Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load. Marine Inspector observed significant oil leaks on the starboard main diesel engine mechanical governor box and aft end of the crank case causing a fire hazard. Vessel must determine the cause of the oil leakage and rectify. 46 CFR 182.05-5
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 May 2022
Resolution: Vessel rep discoved and replaced a worn gasket in governor box and installed a crank case breather tube directed towards the bilge.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 May 2022 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspections. The ship service diesel generator had significant oil leakage from the exhaust manifold flange causing a fire hazard. Vessel must determine the cause of the oil leakage and rectify. 46 CFR 183.01-15
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 May 2022
Resolution: Vessel rep discovered and replaced worn gaskets on the cylinder head cover and exhaust manifold flange connection.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 27 May 2022 Resolved
At each initial and subsequent inspection for certification and reinspection the marine inspector shall examine the bilges and other spaces to see that there is no accumulation of oil or other matter which might create a fire hazard. Marine Inspector observed excess amounts of oily water in the Engine Room bilge. 46 CFR 176.25-50
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 May 2022
Resolution: Bilges free and clear of oily water.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 27 May 2022 Resolved
Each vessel must meet the applicable requirements in Subchapter S of this chapter. MI observed three bulkhead penetrations in the forward bulkhead of the engine room that were not water tight. 46 CFR 177.13-1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 May 2022
Resolution: Bulkhead penetrations made water tight.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 September 2019 Resolved
The construction and arrangement of the vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. While transiting through mm 1 AHP, vessel ran aground. Vessel suffered damage to the port propeller, wheelhouse windows and wheelhouse switch panel. Prior to further operation owner shall make vessel available for inspection to verify proper installment of propeller, proper operation of switch panel, and weather test wheelhouse windows. 46 CFR 177.100
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 September 2019
Resolution: Conducted satisfactory repairs to the port propeller, pilothouse windows, and pilothouse switchpanel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 April 2019 Resolved
Vessels impeller for the port exhaust cooling failed causing the lagging for the engine to over heat and start smoking.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 May 2019
Resolved 12 April 2019
Resolution: Received satifactory report of repairs from company and video showing repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 October 2018 Resolved
all four GENSET mounting bolts found loose
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2018
Resolved 23 October 2018
Resolution: ALL bolts were tightened on the spot
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 October 2018 Resolved
02 PORT/STBD MDE's mount bolts (Aft/Inboard) found loose.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2018
Resolved 23 October 2018
Resolution: All loose bolts tightened.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 October 2018 Resolved
STBD MDE missing hose clamps on exhaust cooling system near overboard discharge.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2018
Resolved 8 November 2018
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 October 2018 Resolved
Fire station on main deck missing valve handle.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2018
Resolved 8 November 2018
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 October 2018 Resolved
Found wiring for stern light twisted together and not made with proper connections.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2018
Resolved 8 November 2018
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 23 October 2018 Resolved
Mount for ladder leading into engine room found broken.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2018
Resolved 8 November 2018
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 23 October 2018 Resolved
P/A speaker on top of cabin found broken and hanging by wire.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2018
Resolved 8 November 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 October 2018 Resolved
Bilge pump wiring not secured in tension clamp/stuffing tube.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2018
Resolved 8 November 2018
Construction/Loadline › Structures › Superstructure
Issued 11 June 2018 Resolved
Tear on the Port Bow bulward and railing. Repair to the satisfaction of Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2018
Resolved 18 June 2018
Resolution: Received photographs of NDT post approved repairs. All sat.

Casualty record · 3

24 January 2010Routine · role: Involved in a Marine Casualty · 1 injured · activity 3670057
7 June 2018Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 6442354
12 September 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 2 injured · activity 6827364
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.