Records from 1999 to 2026. Most recent: inspection, 25 May 2026.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE SHIPYARD · MADISONVILLE, LA, UNITED STATES · built 1999
Hull materialSteel
PropulsionUnknown
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 12 May 2026 · expires 31 May 2027
Service, as the file records itTank Barge
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 42
25 May 2026
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8380103
5 November 2023
Administrative Inspection · Damage Survey · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7820483
17 March 2023
Internal Structural Exam · Drydock Exam · COI Inspection · Examination of Repairs · Cargo Tank Internal
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7652469
29 August 2022
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7546564
25 January 2021
Periodic Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7117826
30 March 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6933699
28 March 2019
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6651413
10 September 2018
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6544302
20 June 2018
Examination of Repairs · Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6450980
28 December 2017
MTSA Verification · Internal Structural Exam · Examination of Repairs · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6323403
15 September 2017
Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6276618
7 December 2016
In-Service Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6054644
27 October 2016
In-Service Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6033028
7 October 2016
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6021254
28 October 2015
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5754405
7 October 2014
MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5002782
22 August 2014
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4965105
18 October 2013
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4736803
23 August 2012
Cargo Tank Internal · MTSA Verification · Drydock Exam · Internal Structural Exam · COI Inspection · Administrative Inspection · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4412031
1 December 2011
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4199576
16 December 2010
MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3911723
26 January 2010
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3671770
30 September 2008
Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3345145
25 May 2008
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3219361
1 October 2007
COI Inspection · Administrative Inspection · MTSA Verification · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3066811
6 December 2006
Annual Inspection
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2835272
6 December 2005
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2546714
27 June 2005
Periodic Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2405295
15 February 2005
Administrative Inspection
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2292882
8 December 2004
MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2255768
29 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978913
11 December 2003
Periodic Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1963219
29 October 2003
Examination of Repairs
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1937206
18 September 2002
Hull Examination · Internal Structural Exam · Cargo Tank Internal · COI Inspection · Examination of Repairs
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1646375
21 December 2001
Examination of Repairs
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1483470
25 October 2001
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 26650
21 September 2001
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 439796
12 March 2001
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1370037
18 January 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 43780
27 January 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 494423
8 January 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 10924
15 December 1999
Initial Certification · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1462046
12 - Dangerous Goods › N/A - No Subsystem › Dangerous goods / harmful substances in pack. form
Issued 25 May 2026
Resolved
No extensive alterations regarding the safety of a tank vessel either in regard to hull or machinery shall be made without the approval of the Commandant. Vessel opeator notified Sector Mobile of multple pinhole leaks on the cargo tank tops which resulted in vapors escaping the cargo tanks #1P, 1S, and 2S. Vessel must provide monitoring plan prior to conducting cargo operations, as well as install boom around the vessel.
46CFR31.10-25
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 May 2026
Resolution: Vessel provided risk assessment and installed boom
12 - Dangerous Goods › N/A - No Subsystem › Other (tankers)
Issued 25 May 2026
Resolved
No extensive alterations regarding the safety of a tank vessel either in regard to hull or machinery shall be made without the approval of the Commandant. Vessel opeator notified Sector Mobile of multple pinhole leaks on the cargo tank tops which resulted in vapors escaping the cargo tanks #1P, 1S, and 2S. Vessel must gas-free all cargo tanks, gauge cargo tanks tops to determine extent of wastage, and provide repair plan.
46CFR31.10-25
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2026
Resolution: Vessel provided repair proposal, unable to gas-free in Mobile, changed code to 15 to allow vessel to depart
12 - Dangerous Goods › N/A - No Subsystem › Other (tankers)
Issued 25 May 2026
No resolution recorded
No extensive alterations regarding the safety of a tank vessel either in regard to hull or machinery shall be made without the approval of the Commandant. Vessel opeator notified Sector Mobile of multple pinhole leaks on the cargo tank tops which resulted in vapors escaping the cargo tanks #1P, 1S, and 2S. Vessel must gas-free all cargo tanks, gauge cargo tanks tops to determine extent of wastage, and provide repair plan.
46CFR31.10-25
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 5 November 2023
Resolved
All tank vessels, the construction or conversion of which is started on or after July 1, 1951, shall conform to the requirements in this subpart in construction of hulls. The hull and deckhouses shall be of steel or iron construction except that the pilothouse and decks over quarters may be constructed of wood. Scantlings, material, and workmanship, subdivision of cargo spaces, fitting of cofferdams, and testing of tanks shall be at least equivalent to the requirements of the American Bureau of Shipping or other recognized classification society. Vessel was involved in a marine casualty resulting in a 12" horizontal crack w/ 1/4" opening on starboard stern quarter just below the top deck. Effect temporary repairs and proceed in accordance with your submitted plan to final destination to make permanent repairs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 November 2023
Resolution: Witnessed repair and final NDT.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 March 2023
Resolved
Except as provided in paragraphs (b) through (g) of this section, each tank vessel must undergo drydock, internal structural, and cargo tank internal examinations as follows: (2) Vessels that operate in fresh water at least six months in every 12 month period since the last drydock examination must be examined in accordance with the intervals set forth in table 31.10–21(b). The dry dock, internal structural exam and cargo tank internal exam was required to be completed in September 2022. The vessel had cargo residue in the cargo tanks between September 2022 until was not gas-freed until March 11, 2023. The dry dock exam was not completed until 21MAR2023, internal structural exam was completed 04APR2023, and the cargo tank internal exam was not completed until 17APR2023. 46 CFR 31.10-21(a)(2)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 17 April 2023
Resolution: All missed exams have been completed.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo Securing Manual
Issued 25 January 2021
Resolved
Prove proper operation of the remote manual shutdown prior to offloading cargo to the satisfaction of an attending USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 February 2021
Resolved 25 January 2021
Resolution: The deficiency was cleared to the satisfaction of an USCG Marine Inspector.
Construction/Loadline › Hull › Hull Plating
Issued 20 June 2018
Resolved
8" hole in stern caused by allision with piling.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 July 2018
Resolved 25 June 2018
Resolution: Repair of 3'x3' on stern void. Air tested. Cleared.
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 7 October 2016
Resolved
1 Meter Gauges color indication fading, almost indistinguishable (2S & 2P). Repair or replace prior to on-loading of next cargo. Offloading of current cargo permitted.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2016
Resolution: Replacement rising stick gauges received and scheduled to be installed.
Deck/Cargo › Vapor Control Systems › Flame Screens
Issued 11 December 2003
Resolved
Flame screen on vacuum side of the high velocity P-V valve had strands missing and look to be improperly repaired by covering up the holes with putty. LEGACY COMPONENT DESC: Flame Screens
Condition: Improper/Lack of Maintenance
Due 10 January 2004
Resolved 27 June 2005