KATIE JO is a 1981 passenger vessel (inspected). The Coast Guard has recorded 12 inspections since 2016, most recently in August 2026, along with 8 deficiencies and 1 operational control.
Records from 2016 to 2026. Most recent: inspection, 19 August 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)40.0 ft × 14.1 ft × 6.1 ft
Registered tonnagegross 23 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY CRAFT INC · LOREAUVILLE LA, UNITED STATES · built 1981
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 30 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it23 - Simplified, Gross Ton 18 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
12 inspections, each with its date, unit and type; 8 deficiencies with the resolution recorded against each; 1 operational control with the dates imposed and removed; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
PlansSign in
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 19 August 2026Resolved
The discharge ends of vent pipes shall be fitted with removable flame screens or flame arresters. The flame
screens shall consist of a single screen of corrosion resistant wire of at least 30 x 30 mesh. The flame screens or flame arresters shall be of such size and design as to prevent reduction in the net cross sectional area of the vent pipe and permit cleaning or renewal of the flame screens or arrester elements. Fuel vent pipe was fitted to the compartment vent and fitted with no flame screen. Rectify deficiency within 7 days. 46 CFR 182.20-35(d)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 August 2026
Resolved 20 August 2026
Resolution: Fuel vent line connected to correct compartment vent. Pictures uploaded.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 23 July 2019Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. The vessels bilge alarms were inoperable and unable to alarm in case of an emergency.
Action required: 30 - Ship detained
Due 24 July 2019
Resolved 24 July 2019
Resolution: Deficiencies have been rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 23 July 2019Resolved
Lakes, bays, and sounds, and rivers routes. A vessel on a lakes, bays, and sounds, or rivers route must carry:
(1) Three hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter,
or other standard specified by the Commandant; signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant.02 distress flares exceeded the manufactures service date.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2019
Resolution: Deficiencies have been rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 July 2019Resolved
Suitable safety guards are installed
in way of rotating machinery, hazardous cable runs and at other appropriate locations. STBD MDE is missing guards around the rotating pulleys.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2019
Resolution: Deficiencies have been rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 July 2019Resolved
(3) The part of the exhaust system between the point of cooling water injection and the engine manifold must
be water-jacketed or effectively insulated and protected in compliance with §§ 177.405(b) and 177.970 of this chapter. Exhaust wrap missing on STBD MDE from the manifold to the point of water injection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2019
Resolution: Deficiencies have been rectified.
Each hatch exposed to the weather must be watertight;
Aft hatch is not functioning correctly allowing water to flood into the space causing a serious flooding and stability concern.
Action required: 30 - Ship detained
Resolved 24 July 2019
Resolution: Deficiencies have been rectified.
10 - Safety of Navigation › N/A - No Subsystem › Navigation bridge visibility
Issued 23 July 2019Resolved
Each vessel must be equipped with a sufficient amount operable portable battery lights. Portable light at the operating station not functioning.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2019
Resolution: Deficiencies have been rectified.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 17 October 2018Resolved
Discovered holes in air intake flexible hoses for port and starboard engines. Replace both flexible hoses to satisfaction of CG Marine Inspector. 46 CFR 176.800(a) 10c
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 17 October 2018
Resolved 17 October 2018
Resolution: Crew replaced both flexible hoses.