MAURY USCG vessel records
← All vessels

FREEDOM

Built
2002
Last inspected
23 February 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 23 February 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 13 calendar years (2003–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ5439
567585
Flag
UNITED STATES
Maury page id
psix-567585

Documentation record

Registered dimensions (L × B × D)70.6 ft × 28.0 ft × 10.2 ft
Registered tonnagegross 184 / net 147
ITC dimensions (L × B × D)70.6 ft × 28.0 ft × 10.2 ft
ITC tonnagegross 98 / net 81
BuilderLA FORCE SHIPYARD INC. · BAYOU LA BATRE, AL, UNITED STATES · built 2002
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 4 May 2026 · expires 30 April 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it81 - Convention (Subpart B), Net Ton
147 - Simplified, Net Ton
184 - Simplified, Gross Ton
98 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 18 inspections, each with its date, unit and type; 2 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 9 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 9

Inspection history · 18

23 February 2026 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8318567
1 April 2025 Administrative Inspection · COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8103568
17 February 2023 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7638322
23 September 2022 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7566613
5 July 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7497460
10 May 2022 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7466655
13 October 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7075861
10 June 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6973032
2 March 2020 Initial Certification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6918768
15 February 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6653807
29 April 2014 Industry Initiated Exam · Deficiency Check · DAPI Audit · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4846353
7 April 2013 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4566097
5 April 2013 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4565495
12 July 2010 Industry Initiated Exam · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3796042
14 November 2008 Administration
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3362987
22 April 2005 Administrative Inspection
Administrative · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2340542
18 August 2004 MTSA Verification
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 2171427
8 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1961060

Deficiency record · 2

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 June 2020 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Vessel experienced a loss of propulsion when the STBD Main Diesel Engine shut down. Prior to movement provide TPO/Technician's report attesting to the satisfactory repairs and test of the STBD Main Diesel Engine to the attending USCG Marine Inspector. 46 CFR 143.205 (a)
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 11 June 2020
Resolved 10 June 2020
Resolution: Recieved TPO/Technician's report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 June 2020 Resolved
Fuel systems for towing vessel main engines and generators must have a documented maintenance plan to ensure proper operation of the system. This plan should be available to the DMI and/or attending Marine Inspectors to satisfy the material condition of filters, valves, and associated equipment. Additionally, spare filters must be available on board and replenished within the timelines laid out in the vessel’s TSMS or maintenance plan. Provide documented maintenance plan to USCG Marine Inspector. 46 CFR 143.255 (a)-(c).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 10 June 2020
Resolution: Submitted sat. tech report on the replacement of the filters

Ownership record