Records from 2003 to 2026. Most recent: inspection, 11 July 2026.
Inspection history · 70
11 July 2026
Examination of Repairs · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8435095
25 August 2025
Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8210680
4 June 2025
Deficiency Check · In-Service Inspection · Administrative Inspection · Periodic Inspection · Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8151620
13 March 2025
Examination of Repairs · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8093476
31 October 2024
Examination of Repairs · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8027504
31 October 2024
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8043943
12 July 2024
Administrative Inspection · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7956517
11 September 2023
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7790157
25 July 2023
Examination of Repairs · Administrative Inspection · Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7751536
9 January 2023
Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7618473
3 January 2023
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7615699
23 November 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7599438
9 August 2022
COI Inspection · MTSA Verification · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7522032
15 April 2022
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7433052
8 February 2022
Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7391123
31 January 2022
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 7396467
30 January 2022
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 7387961
23 December 2021
Examination of Repairs · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7371710
12 July 2021
Examination of Repairs · Deficiency Check · Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7253229
14 May 2021
Damage Survey · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7197012
23 October 2020
MTSA Verification · Examination of Repairs · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7082852
8 October 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7073758
17 April 2020
Administrative Inspection · Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6940518
3 April 2020
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6944646
28 March 2020
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6936917
15 November 2019
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6856579
8 October 2019
Administrative Inspection · Examination of Repairs · MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6830842
30 August 2019
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6799147
7 January 2019
Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6608147
11 December 2018
Damage Survey · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6596089
13 September 2018
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6539679
17 March 2018
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6574995
18 August 2017
Cargo Tank Internal · COI Inspection · MTSA Verification · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6242277
11 July 2017
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6207465
1 May 2017
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6133540
13 June 2016
MTSA Verification · COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5906175
19 June 2015
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5157823
18 June 2015
Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5157831
9 June 2015
Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5148666
22 May 2015
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5129523
3 December 2014
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5035101
30 September 2014
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5176597
22 May 2014
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4865639
29 September 2013
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4726050
11 December 2012
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4500341
22 May 2012
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4321693
7 May 2012
Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4304388
1 March 2012
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4254600
8 April 2010
MTSA Verification · Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3711843
26 February 2010
Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3686678
22 April 2009
Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3458093
23 October 2008
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3350603
16 October 2008
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3345678
25 February 2008
Internal Structural Exam · COI Inspection · MTSA Verification
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3150621
27 August 2007
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3039766
25 March 2007
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2896962
15 March 2007
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2889308
1 February 2007
Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2865808
18 December 2006
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2842246
23 May 2006
MTSA Verification · Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2657615
6 March 2006
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2598513
27 July 2005
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2441692
29 April 2005
MTSA Verification · Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2345448
18 February 2005
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2323990
8 October 2004
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2216790
3 September 2004
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2185229
28 April 2004
Annual Inspection · Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2053934
21 October 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1950261
17 April 2003
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1783832
28 February 2003
Internal Structural Exam · Deadweight Survey · Initial Certification · COI Inspection · Cargo Tank Internal · Hull Examination · Construction Oversight
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 1736836
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 23 June 2025
Resolved
Scantlings, material, and workmanship, subdivision of cargo spaces, fitting of cofferdams, and testing of tanks shall be at least equivalent to the requirements of the American Bureau of Shipping or other recognized classification society.
Marine Inspectors discovered extensive amounts of pitting and wastage throughout the walking deck.
Vessel shall enact repairs and renew all wasted plate identified prior to departure to the satisfaction of a Coast Guard Marine Inspector.
46 CFR 32.60-1(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 July 2025
Resolution: Completed repairs of wasted deck locations identified by USCG MI's. Repairs tested satisfactorily.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 June 2025
Resolved
Any tank vessel which is equipped with an internal combustin engine driven cargo pump on the weather deck shall be provided with a minimum of one remote manual shutdown station, conspicuously marked, and located at the midpoint of such vessel, or 100 feet from the engine.
Vessel unable to start the starboard side prime mover and satisfactorily test the remote manual shutdown station.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 June 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 June 2025
Resolved
Thermal fluid heaters are examined by a marine inspector at the inspection for certification, periodic inspection and when directed by the Officer in Charge, Marine Inspections, to determine that the complete unit is in a safe and satisfactory condition.
Vessel unable to start the generator powering the thermal fluid heater.
Vessel is restricted from conducting cargo operations with Grade E cargoes until this deficiency is rectified.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 June 2025
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 31 October 2024
Resolved
All tank vessels, the construction or conversion of which is started on or after July 1, 1951, shall conform to the requirements in this subpart in construction of hulls. Barge grounded on some rocks and flooded #1 STBD void. Vessel is authorized to complete transit to FMT Shipyard. vessel must submit damage assessment and repair plans prior to effecting permanent repairs. 60c. 46 CFR 32.60-1(a)
Action required: 60 - Rectify deficiencies prior to movement
Due 31 October 2024
Resolved 12 November 2024
Resolution: Attended vessel to witness permanent repair made on #1 Stbd void and NDT of repair. All sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 July 2024
Resolved
Scantlings, material, and workmanship, subdivision of cargo spaces, fittings of cofferdams, and testing of tanks shall be at least equivalent to the requirements of the American Bureau of Shipping or other recognized classification society. Vessel rep identified pinholes in cargo tank. Complete repairs to the satisfaction of the attending Marine Inspector prior to loading cargo.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 August 2024
Resolved 6 August 2024
Resolution: Vessel corrected pinholes located at top of 1-5 P/S cargo tanks.
02 - Structural Conditions › N/A - No Subsystem › Cargo area segregation
Issued 25 July 2023
Resolved
The hull and deckhouses shall be of steel or iron construction except that the pilothouse and decks over quarters may be constructed of wood. Scantlings, material, and workmanship, subdivision of cargo spaces, fitting of cofferdams, and testing of tanks shall be at least equivalent to the requirements of the American Bureau of Shipping or other recognized classification society. Received report of pinhole leak in the #5 port cargo tank. Prior to loading cargo, vessel must repair pinhole leak, and perform a vapor tightness test. 46 CFR 32.60-1(a)
Action required: 705 - Other - as specified
Resolved 1 August 2023
Resolution: Conducted satisfactory air test of #5 port cargo tank.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 23 November 2022
Resolved
Pinhole leak found on #5 Port Cargo Tank in the port forward machinery deck containment area. Vessel is authorized a one time transit from Intergulf Fleeting to Channelview Shipyard Lynchburg to enact permanent repairs to the satisfaction of a CG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 November 2022
Resolution: Repaired in kind. Plate Summary attached to documents.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 14 May 2021
Resolved
Reach rod pipe cracked.
Action required: 60 - Rectify deficiencies prior to movement
Due 1 June 2021
Resolved 25 May 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 October 2020
Resolved
Both prime moveres onboard GM 8301 need repairs.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 October 2020
Resolved 6 November 2020
Resolution: Witnessed satisfactory operation of both prime movers while onboard.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 7 January 2019
Resolved
Scantlings, material, and workmanship, subdivision of cargo spaces, fitting of cofferdams, and testing of tanks shall be at least equivalent to the requirements of the American Bureau of Shipping or other recognized classification society. Prior to departure, vessel will be attended by Coast Guard marine inspector and copies of all independent surveys relating to reported grounding and collision wil be provided to satisfaction of the attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 6 February 2019
Resolved 8 January 2019
Resolution: Surveyor completed survey. No apparent damage identified by surveyor or attending marine inspector.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 13 September 2018
Resolved
Remote quick acting manual shutdown shall be installed on the engines so as to provide a quick and effective means of stopping the engine.
Engines aboard vessels could not be started to prove proper operation of emergency shutdowns.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 September 2018
Resolution: Marine Inspectors witnessed satisfactoy test of emergency shutdown on cargo pump engines.
Construction/Loadline › Structures › Deck Plating
Issued 30 June 2017
Resolved
Provide non destructive gauging report of all areas identified during inspection of cargo tank top. These areas include deep pitting of greater than 1/8” found using a pit gauge. Prior to conducting cargo operations, to the satisfaction of attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 30 July 2017
Resolved 21 August 2017
Resolution: Recieved and reviewed gauging report from RIO marine
Construction/Loadline › Structures › Deck Plating
Issued 30 June 2017
Resolved
Provide repair plan for any wastage identified to be greater than 25% of original scantlings.
Action required: 705 - Other - as specified
Due 30 July 2017
Resolved 21 July 2017
Resolution: Recieved repair plan for GM 3801
Construction/Loadline › Structures › Deck Plating
Issued 1 May 2017
Resolved
Complete approved repairs as listed below prior to conducting cargo operations, 1) One cargo tank top insert 2’ X 2’ located in the # 2 starboard cargo tank close to the containment rail 2) One cargo tank top insert 2’ X 8’ located on the starboard side Machinery deck just outside the fuel tank 3) One cargo tank top insert 10’ X 37 located on the port side machinery deck.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 July 2017
Resolved 25 August 2017
Resolution: All repaires have been made to the satisfation of the attending Marine Inspaector
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 26 May 2015
Resolved
Sections of exhaust Lagging on Port and Starboard cargo pump engines and generator are missing, others are not secured. Vessel must install and properly secure lagging on pipes greater than 150F.
Due 26 June 2015
Resolved 9 June 2015
Resolution: New exhaust lagging was in place and securely fastened.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 May 2015
Resolved
Vessel is often used as a head barge did not have navigation light screens installed.
Due 26 May 2015
Resolved 26 May 2015
Resolution: Properly painted navigation screens were installed during the inspection.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 May 2015
Resolved
Improperly terminated wiring. Wiring to removed deck floodlights and navigation light plugs was cut, wrapped in electrical take and placed in electrical piping on deck. Wires were still connected to circuit breakers in distribution panel allowing and could easily be accidently energized.
Condition: Improper/Lack of Maintenance
Due 26 May 2015
Resolved 26 May 2015
Resolution: Vessel removed all unneeded wire from distribution panel and deck.
Documentation › Markings/Placards › Capacity Marking
Issued 22 April 2009
Resolved
Label cargo hoses with service for which it is used and maximum allowable working pressure, prior to its use.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 April 2009
Resolved 22 April 2009
Resolution: Corrected on the spot.
Documentation › Markings/Placards › Capacity Marking
Issued 22 April 2009
Resolved
Remove test pressure marking off cargo hose.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 May 2009
Resolved 25 May 2011
Resolution: Hose inspected sat.
Deck/Cargo › Vapor Control Systems › Flame Screens
Issued 22 April 2009
Resolved
Replace flame screen on 1 STBD, 3 STBD, and 5 STBD Cargo Tank P/V's prior to loading cargo.
Action required: 705 - Other - as specified
Due 22 April 2009
Resolved 22 April 2009
Resolution: Corrected on the spot.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 13 August 2008
Resolved
Vessel resubmission is overdue. The TVRP must be amended to verify intended areas of operation/COTP zones, and identify contact information for border states before approval is granted.
Due 13 September 2008
Resolved 3 February 2009
Resolution: Vessel resubmission approved 2/3/2009 with revisions received 1/28/2009. New vessel VRP expiration date 2/28/2014.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Gaskets
Issued 28 April 2004
Resolved
Repack cargo valves as follows:
1. All valves for 5P/5S manifold
2. Four forward valves 4P/4S manifold
3. Four forward valves 3P/3S manifold
4. Suction valve 2S manifold
5. Suction valve 1P manifold
Action required: 705 - Other - as specified
Due 28 May 2004
Resolved 3 September 2004
Resolution: Valves repacked
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 28 April 2004
Resolved
Replace flame screen for 3P P/V valve
Action required: 705 - Other - as specified
Due 28 May 2004
Resolved 3 September 2004
Resolution: Flame screen has been replaced.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 28 April 2004
Resolved
Re-mark cargo hose with correct test date and MAWP.
Action required: 705 - Other - as specified
Due 28 May 2004
Resolved 3 September 2004
Resolution: Cargo hose stenciled with correct test date and MAWP.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Manifold
Issued 28 April 2004
Resolved
Remove marking from cargo pipeline. (incorrect date)
Action required: 705 - Other - as specified
Due 28 May 2004
Resolved 3 September 2004
Resolution: Corrected information stenciled cargo pipeline.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 28 April 2004
Resolved
Re-stencil all faded "Danger Keep Out" markings.
Action required: 705 - Other - as specified
Due 28 May 2004
Resolved 3 September 2004
Resolution: Danger Keep Out has been restenciled.
Electrical
Issued 28 April 2004
Resolved
Prove proper operation of generator 480V ground detection light.
Action required: 705 - Other - as specified
Resolved 28 April 2004
Electrical › Electric Generation Source (service) › Generator Cable
Issued 28 April 2004
Resolved
Renew cable jacket in between junction box and aft light stand.
Action required: 705 - Other - as specified
Due 28 May 2004
Resolved 3 September 2004
Resolution: Cable jacket between junction box and aft light stand has been replaced.
Engineering › Diesel Engine (auxiliary) › Pump, Positive Displacement
Issued 28 April 2004
Resolved
Prove level of coolant in stbd cargo pump engine sight glass.
Action required: 705 - Other - as specified
Due 28 May 2004
Resolved 3 September 2004
Resolution: Level of coolant has been corrected.
Deck/Cargo
Issued 28 April 2004
Resolved
Provide documentation of annual testing of cargo relief valve and cargo pressure gauge.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2004
Documentation › Certificates/Documents
Issued 28 February 2003
Resolved
Submitted to MSC 24FEB03. LEGACY COMPONENT DESC: Certificate of Financial Responsibility
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2003
Resolution: COFR verified/sighted.
Documentation › Safety/Response Plans/Programs
Issued 28 February 2003
Resolved
Submitted to MSC 21FEB2003 LEGACY COMPONENT DESC: Vessel Response Plan
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2003
Resolution: VRP approved ltr confirmed/sighted.