Records from 2003 to 2026. Most recent: operational control imposed, 30 July 2026.
Inspection history · 34
30 July 2026
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8450680
27 April 2026
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8355683
13 January 2026
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8295405
10 January 2026
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8294209
29 November 2025
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8274409
9 June 2025
Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8155582
22 May 2025
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8141316
18 May 2025
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8138347
9 November 2024
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8032618
8 March 2017
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6099475
28 February 2017
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6096495
6 July 2016
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5931927
2 July 2016
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 5926310
1 July 2016
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5926098
28 March 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5842102
14 March 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5833000
13 January 2016
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5796461
12 July 2011
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4078713
30 November 2010
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3900905
12 July 2008
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3265418
5 May 2008
PII Safety Exam · ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3196266
6 October 2005
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2509352
6 October 2005
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2509362
6 October 2005
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2511833
28 April 2005
PII Safety Exam · Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination · Random ISPS/MTSA/PSC
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2344654
16 November 2004
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2263269
15 November 2004
PII Safety Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2241031
25 August 2004
ISPS II Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2176442
8 June 2004
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2091971
19 March 2004
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2027647
16 March 2004
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2025258
1 October 2003
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1918793
28 January 2003
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1736246
27 January 2003
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1736199
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 January 2026
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service...Vessel reported fluctuations on main engine RPM gauges when in dead slow ahead. Vessel shall provide satisfactory class report attesting to repairs and/or cause of malfuntion and proposed repair plan to Coast Guard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 January 2026
Resolution: Provided satisfactory class report.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 18 May 2025
Resolved
Oil fuel pipes, which, if damaged, would allow oil to escape from a storage, settling, or daily service tank having a capacity of 500l and above situated above the double bottom, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the spaced concerned in the event of a fire occuring in the space in which such tanks are situated. PSCO observed an obstruction (bolt) improperly installed on the diesel oil service tank remote fuel shutoff valve in the purifier room, rendering inoperable.
74 SOLAS (04) II-2/2.2.3.4
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 May 2025
Resolution: Rectified during exam. Obstruction removed.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 18 May 2025
Resolved
The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant rules and regulations established by the company. The technical and operational nature of the deficiency noted above provides objective evidence of a serious failure of the implementation of the ISM code. An internal audit report satisfactory to the OCMI must be submitted within three months.
74 SOLAS (20) IX/3.1
ISM Part A/10.1
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 June 2025
Resolution: Provided internal audit report
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 8 March 2017
Resolved
74 Solas (2009) III/20.2 - 0610 - Starboard side survival craft's tiller would not maneuvor to port or starboard.
Action required: 705 - Other - as specified
Resolved 8 March 2017
Resolution: Chief Engineer changed out and replaced a pin that attached steering cable to the conning station.
Operations/Management › Pollution › Control of Garbage
Issued 12 July 2011
Resolved
Every ship 500 gross tons and above shall carry a garbage management plan that provides written procedures for collecting, storing, processing and disposing of garbage. the trash receptacles on board were found to be color coded and labeled, but no color coding is in the plan. The ship is also burning aerosol cans and metal in the incinerator, trash is being mixed in receptacles that are labeled.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 July 2011
Resolved 12 July 2011
Resolution: Ship has fixed their garbage stowage procedures to reflect the plan.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 12 July 2011
Resolved
Machinery shall be maintained for the purpose for which it is intended. The incinerator heat shielding is missing and falling into main body, causing a fire and safety hazard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 July 2011
Resolved 12 July 2011
Resolution: Ships company has been notified that heat shielding inside of incinerator needs to be replaced.
Lifesaving › Launching Appliances › Davit
Issued 28 January 2003
Resolved
The wire falls for lifeboats not seating squarely on the sheaves, wire rests against the walls on all the sheaves. Class to exam the way the wire lays is satisfactory, and vessel to send report to Coast Guard.
Action required: 705 - Other - as specified
Due 28 March 2003
Resolved 29 January 2003
Resolution: Cleared by fax from RINA
Lifesaving › Lifeboat › Propulsion Starting System
Issued 28 January 2003
Resolved
Vessel's crew not able to start lifeboats. Class to witness operational test of both lifeboat engines prior to the vessel departure from the Port of New York.
Action required: 705 - Other - as specified
Due 28 January 2003
Resolved 29 January 2003
Resolution: Cleared by fax from RINA