MAURY USCG vessel records
← All vessels

DOUBLE SKIN 57

Built
2004
Last inspected
6 November 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 6 November 2025
…with no type recorded9
Operational controls None recorded without a removal date
Years with a record 21 calendar years (2004–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

670861
Flag
UNITED STATES
Maury page id
psix-670861

Documentation record

Registered dimensions (L × B × D)362.5 ft × 62.0 ft × 24.0 ft
Registered tonnagegross 4,530 / net 4,530
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFBOAT LLC · JEFFERSONVILLE, IN, UNITED STATES · built 2004
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portBALTIMORE, MD
Endorsements, as the file codes themcw_un, reg_nfv
DocumentationValid · issued 14 November 2025 · expires 31 October 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it4530 - Simplified, Gross Ton
4530 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 45 inspections, each with its date, unit and type; 20 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 5 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 5

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

PENN NO. 92 Tank Barge · MISLE 936872 · 31 January 2023 · activity 7631262RTC 106 Tank Barge · MISLE 1167279 · 2 May 2022 · activity 7446554ANACOSTIA Towing Vessel · MISLE 967536 · 12 December 2010 · activity 3909239NANTICOKE Towing Vessel · MISLE 731283 · 19 July 2009 · activity 3541269CHOPTANK Towing Vessel · MISLE 852361 · 15 February 2008 · activity 3152435

Inspection history · 45

6 November 2025 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8264999
20 December 2024 COI Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8046629
25 October 2024 Cargo Tank Internal · Internal Structural Exam · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8024623
18 October 2024 Damage Survey · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8020918
14 July 2024 Bulk Liquid Transfer Monitor
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7957798
14 February 2024 MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7862847
17 May 2023 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7690877
21 February 2023 Administrative Inspection · MTSA Verification · Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7639616
31 January 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7631262
15 November 2022 Internal Structural Exam · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7594970
2 May 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7446554
17 February 2022 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7397893
20 July 2021 Bulk Liquid Transfer Monitor
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7261750
5 March 2021 Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7150939
9 January 2020 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6886375
9 December 2019 MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6869848
7 November 2019 Drydock Exam · Internal Structural Exam · Cargo Tank Internal
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6851148
16 November 2018 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6583571
15 November 2017 Internal Structural Exam · Periodic Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6307097
27 February 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6097644
20 December 2016 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6060220
3 December 2015 Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5774421
5 June 2015 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 5144933
3 December 2014 Internal Structural Exam · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5034672
17 October 2014 MTSA Verification · COI Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5006207
15 January 2014 COI Inspection · MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4778703
29 November 2012 Annual Inspection · SIP Inspection/Audit · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4492493
16 October 2012 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4465505
27 October 2011 MTSA Verification · Annual Inspection · SIP Inspection/Audit
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4177173
12 December 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3909239
3 November 2010 MTSA Verification · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3882610
19 July 2009 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3541269
18 November 2008 Annual Inspection · MTSA Verification · SIP Inspection/Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3365236
15 February 2008 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3152435
6 December 2007 SIP Initial Entry
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3176070
6 November 2007 Internal Structural Exam · MTSA Verification · SIP Inspection/Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3093932
27 July 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3008986
8 May 2007 SIP Initial Entry
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3176008
5 December 2006 MTSA Verification · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2865846
12 July 2006 SIP Initial Entry
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3175944
22 November 2005 SIP Initial Entry · MTSA Verification · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2539278
24 March 2005 MTSA Verification
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2322820
25 February 2005 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2301181
4 November 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2235033
28 October 2004 Hull Examination · Internal Structural Exam · Cargo Tank Internal · Initial Certification · MTSA Verification
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2229833

Deficiency record · 20

14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 6 November 2025 Resolved
The remote quick acting manual shutdown shall be installed on the engine so as to provide a quick and effective means of stopping the engine (such as by cutting off the intake air). STBD cargo pump prime mover unable to effectively stop using remote shutdown. Repair to satisfaction of attending marine inspector prior to discharging or transferring cargo with the STBD Cargo Pump. 46 CFR 32.50-35 (a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 November 2025
Resolution: Received satisfactory video evidence.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 6 November 2025 Resolved
If installed after July 23, 1990, the high-level alarm and tank overfill alarm required by paragraph (a) of this section must - (2) activate an alarm in the event of loss of power to the alarm system. When tested, alarms were not present on the cargo deck. 46 CFR 39.2007 (b) (2)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 January 2026
Resolved 12 January 2026
Resolution: Report attached to docs tab outlining alarm servicing/testing. All sat.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 20 December 2024 Resolved
Each vessel vapor connection flange face must have a permanent stud projecting outward that has a 12.7 millimeter (0.5 inch) diameter and is at least 25.4 millimeters (1 inch) long. It must be located at the top of the flange face, midway between boltholes, and in line with the bolthole pattern. MI observed a VCS flange without a permanent stud. 46 CFR 39.2001(j)
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 20 December 2024
Resolved 2 January 2025
Resolution: O/O installed vapor line alignment stud.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 20 December 2024 Resolved
No person shall conduct an oil or hazardous material transfer operation unless the discharge containment required by §§ 154.530, 155.310, and 155.320 of this chapter, as applicable, is in place and periodically drained to provide the required capacity. MI observed current condition of discharge containment is not suitable for transfer operations. 33 CFR 156.120(n)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 December 2024
Resolved 2 January 2025
Resolution: O/O removed equipment from containment drainage.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 December 2024 Resolved
Each vessel must carry lifebuoys approved under approval series 160.150. MI observed 02 life rings missing retro-reflective tape. 46 CFR 199.70(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 January 2025
Resolved 2 January 2025
Resolution: O/O replaced retro-reflective tape.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 October 2024 Resolved
The Coast Guard may re-inspect at any time any vessel subject to inspection under 46 USC. During re-inspection if any defects or imperfections are discovered or when repairs become necessary the Coast Guard will notify the master and state what is required. The Duty Marine inspector received report from Vessel Traffic Service the Barge was soft aground IVO Buoy 2 at PNCT. Barge required to remain at lay berth until Marine Inspectors conducts damage survey to determine seaworthiness. 46 CFR 2.01-10(b) - 701 (c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 October 2024
Resolution: MI observed no obivious damage to wing voids. No water ingress on Port and STBD sides.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 February 2024 Resolved
Electric installations on vessels must ensure protection of passengers, crew, other persons and the vessel from electrical hazards. Generators not intended to be operated in parallel, shall be electrically or mechanically interlocked to prevent accidental out of phase paralleling. Install mechanical interlock on switchboard to prevent accidental paralleling in accordance with the manufacture instructions.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 March 2024
Resolved 28 February 2024
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 May 2023 Resolved
While moored, vessel's hull was punctured by the dock in the forward rake stbd side 12' above the waterline. Vessel is to transit directly to Court St for permanent repairs.
Action required: 705 - Other - as specified
Due 17 May 2023
Resolved 22 May 2023
Resolution: Passed final weld and NDT for 24" x 24" insert. All sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 February 2023 Resolved
All tank vessels, except unmanned tank barges, contracted for on or after July 1, 1969, shall have efficient guard rails or bulwarks on decks and bridges. The height of rails or bulwarks shall be at least 39-1/2 inches from the deck except that where this height would interfere with the normal operation of the vessel, a lesser height may be approved by the Commandant. At exposed peripheries of the freeboard and superstructure decks the rails shall be in at least three courses including the top. The opening below the lowest course shall not be more than 9 inches. The courses shall not be more than 15 inches apart. 03 courses of chain are missing from the STBD aft quarter. 46 CFR 32.02-10
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 March 2023
Resolved 24 February 2023
Resolution: Operator installed chains.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 21 February 2023 Resolved
Operational tests and checks of all safety and limit controls, combustion controls, programming controls, and safety relief valves must be conducted by the owner, chief engineer, or person in charge at the inspection for certification, periodic inspection, and when directed by the Officer in Charge, Marine Inspection, to determine that the control components and safety devices are functioning properly and are in satisfactory operating condition. The system must be locked-out in order to prevent operation in lieu of required tests. Marine inspector discovered system was not properly tagged out. 46 CFR 61.30-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 March 2023
Resolved 24 February 2023
Resolution: Operator disconnected fuel lines and tagged-out the system.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 November 2022 Resolved
Replace FWD most rail stanchion on STBD side
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 December 2022
Resolved 7 December 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 5 March 2021 Resolved
33CFR156.120(r): The emergency means of shutdown required by §§154.550 and 155.780 of this chapter, as applicable, is in position and operable. Aft pull station for Port transfer pump inoperable. Repair aft pump emergency shut down.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 March 2021
Resolved 5 March 2021
Resolution: MI received evidence of aft emergency pull station was working properly.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 5 March 2021 Resolved
Each cargo tank of a tank barge must have one of the following liquid overfill protection arrangements, a system meeting the requirements of 46 CFR 39.2007. Loss of power alarm to liquid overfill protection panel inoperable. Replace battery. 46CFR39.2009:
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 March 2021
Resolved 5 March 2021
Resolution: MI received evidence of panel operating during loss of power.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 December 2019 Resolved
Operational tests and checks of all safety and limit controls, combustions controls, programming controls, and safety relief valves must be conducted at the inspection for certification, periodic inspection, and when directed by the [name withheld] could not provide objective evidence that the thermal fluid heater safety relief valve had been tested since installation.
Action required: 10 - Deficiency Rectified
Resolved 10 December 2019
Resolution: Operator bench tested valve and provided certificate.
Construction/Loadline › Structures › Rake
Issued 15 November 2017 Resolved
See emailed and scanned worklist for items to be corrected prior to next credit dry dock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2019
Resolved 18 November 2019
Resolution: Completed all repairs
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 15 November 2017 Resolved
The bellows on both cargo pumps are not vapor tight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 16 November 2017
Resolution: Recieved pictures verifying replacement.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 30 January 2014 Resolved
Both port and starboard cargo pump shaft penetration through the bulkhead are not gas tight. IAW 46 cfr 32.50-1 where cargo pump shafts pierce gas tight bulkheads, stuffing boxes with readily accessible gas tight glands shall be provided.
Due 2 March 2014
Resolved 4 April 2014
Resolution: Verified proper gas tight penetration of shaft.
Electrical › Lighting (service) › Lighting Fixture
Issued 30 January 2014 Resolved
Both port and starboard flood lights above the cargo pump room are currently located within the hazardous location and do not meet the Class 1 Div 1 requirements. IAW 46 cfr 111.05-31(L)1 Lighting in hazardous areas are required to be intrinsically safe or explosion proof.
Due 2 March 2014
Resolved 4 April 2014
Resolution: Verified proper placement of lights, 10ft from cargo opening.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 15 January 2014 Resolved
High level alarm and tank overfill alarm must activate an alarm in the event of loss of power to the alarm system. 46 CFR 39.2007
Action required: 705 - Other - as specified
Due 29 January 2014
Resolved 29 January 2014
Resolution: Received email video of vessel representative conducting a satisfactory test of the High level/Tank overfill power failure alarm.
Deck/Cargo › Cargo Stowage › General
Issued 3 November 2010 Resolved
Wasted and loose mounting brackets pertaining to storage container on deck top.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 January 2011
Resolved 13 December 2010
Resolution: Witnessed the proper installation of mounting brackets for paint locker.