MAURY USCG vessel records
← All vessels

KUN PENG

Built
2005
Last inspected
14 May 2024
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 14 May 2024
…with no type recorded7
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9272503
744349
Flag
HONG KONG
Maury page id
psix-744349

Documentation record

Tonnage as PSIX records it45617 - Dead Weight, Metric Ton
54780 - Displacement, Metric Ton
28131 - Convention (Subpart B), Gross Ton
11696 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 16 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 4 other vessels inspected with it; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

POINT CLEAR Towing Vessel · MISLE 491887 · 21 February 2016 · activity 6091887LADY OF GUADALUPE Towing Vessel · MISLE 930844 · 21 February 2016 · activity 6091887KIRBY 30047T Tank Barge · MISLE 1278526 · 21 February 2016 · activity 6091887RENA MARIE Towing Vessel · MISLE 1327828 · 21 February 2016 · activity 6091887

Inspection history · 16

14 May 2024 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7912394
3 May 2024 PSC B · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7903563
2 December 2022 COC-TVE Annual
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7603060
29 November 2022 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7601328
30 July 2022 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7520281
21 January 2022 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7382152
10 September 2021 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7304479
20 June 2020 PSC B · COC-CHEM & TVE Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6981849
28 June 2019 COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6720086
3 September 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6530868
30 July 2018 ISPS II Exam · COC-CHEM Annual · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6487186
5 March 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6366257
21 October 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6292169
21 April 2017 ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6125478
19 June 2016 COC-CHEM & TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5911799
21 February 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6091887

Deficiency record · 6

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 3 May 2024 Resolved
Cargo tanks shall be fitted with a visual and audible high-level alarm which indicates when the liquid level in the cargo tank approaches the normal full condition. PSCO observed inoperable tank gauging for cargo tank #6 starboard in cargo control room.
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 May 2024
Resolution: Class report submitted.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 3 May 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the present regulations. PSCO observed approximately 04 malfunctioning pressure and temperature sensors in the cargo control room.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 May 2024
Resolution: Class report submitted.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 3 May 2024 Resolved
The company is responsible for ensuring that adequate resources and shore based support are provided to enable the designated person(s) to carry out their functions. Company failed to notify Class of the issues above. 74SOLAS(20) IX/3.1 ISM 3.3
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 May 2024
Resolution: Class report submitted.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 2 December 2022 Resolved
the condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects remain fit to proceed to sea without danger to the ship or persons on board. PSCO identified a leak in the emergency water line due to the corrosion.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2022
Resolved 11 December 2022
Resolution: ABS Certified repairs conducted.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 2 December 2022 Resolved
the condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects remain fit to proceed to sea without danger to the ship or persons on board. PSCO found leak on the hydraulic lin for deep well pump on cargo tank #1.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2022
Resolved 11 December 2022
Resolution: ABS Certified repairs conducted.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 19 June 2016 Resolved
1499 - other (prop. & aux machinery) - Shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum danger to persons on board. PSCO observed an exhaust leak in the edg room during testing. 74 SOLAS (04) II-1/26 17a
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2016
Resolution: Received class report attesting to replacement of exhaust gas silencer and subsequent testing.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.