MAURY USCG vessel records
← All vessels

LADY OF GUADALUPE

Built
2007
Last inspected
19 April 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 19 April 2026
…with no type recorded28
Operational controls None recorded without a removal date
Years with a record 17 calendar years (2008–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDG2401
930844
Flag
UNITED STATES
Maury page id
psix-930844

Documentation record

Registered dimensions (L × B × D)74.5 ft × 30.0 ft × 10.0 ft
Registered tonnagegross 149 / net 119
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRODRIGUEZ BOAT BUILDERS INC · CODEN, AL, UNITED STATES · built 2007
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 12 December 2025 · expires 31 January 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it149 - Simplified, Gross Ton
119 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 38 inspections, each with its date, unit and type; 8 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 9 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 9

Inspection history · 38

19 April 2026 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8352383
19 April 2026 Administrative Inspection · In-Service Inspection · Deficiency Check · Vessel Attendance
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8353349
8 February 2026 Administrative Inspection · COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8307652
21 May 2024 Type not recorded
No type recorded · Station Freeport · USCG Heartland District (CGD-H) · Activity 7916813
7 October 2023 Type not recorded
No type recorded · Station Freeport · USCG Heartland District (CGD-H) · Activity 7805260
5 April 2023 Type not recorded
No type recorded · Station Freeport · USCG Heartland District (CGD-H) · Activity 7664488
13 November 2022 Type not recorded
No type recorded · Station Sabine · USCG Heartland District (CGD-H) · Activity 7593868
4 August 2022 Damage Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7524876
4 August 2022 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7528687
19 February 2021 Initial Certification
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7145699
25 March 2019 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6655806
17 July 2018 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6482222
28 November 2017 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6313927
20 July 2017 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6215341
24 October 2016 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6028815
26 August 2016 MTSA Verification · Industry Initiated Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5996496
4 August 2016 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5963305
21 February 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6091887
5 January 2016 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5791563
15 January 2015 Administration
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5053586
9 October 2014 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5014136
7 October 2014 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5000820
30 October 2013 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4744020
3 August 2013 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4675259
31 July 2013 Deficiency Check · DAPI Audit · MTSA Verification · Industry Initiated Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4683658
19 June 2013 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4625373
23 May 2013 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4603898
11 February 2013 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4533249
1 July 2012 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4364385
4 May 2012 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4302143
29 September 2011 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4160641
5 April 2011 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3981432
10 August 2010 MTSA Verification · Industry Initiated Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3820023
22 November 2009 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3660929
9 June 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3500197
21 May 2009 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3539979
21 April 2009 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3458188
24 July 2008 Uninspected Other
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3278534

Deficiency record · 8

Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pressure/Vacuum Relief Valve
Issued 11 February 2013 Resolved
46 CFR 55-25 (A) & 46 CFR 55-25 (B). SEE NARRATIVE FOR DETAILS
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 February 2013
Resolved 15 January 2015
Resolution: This deficiency was issued in error.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 25 July 2008 Resolved
Publications were not available.
Condition: Unknown
Due 26 July 2008
Resolved 5 November 2008
Resolution: Vessel was reinspected with new owners and item found to be corrected.
Fire Fighting › Fixed Fire Detection System › Approval
Issued 25 July 2008 Resolved
System was not certified.
Condition: Placed in Improper Service
Due 26 July 2008
Resolved 5 November 2008
Resolution: Vessel was reinspected with new owners and item found to be corrected.
Fire Fighting › Portable CO2 Fire Extinguisher › Marine Type Label
Issued 25 July 2008 Resolved
Extinguishers had no nameplates.
Condition: Placed in Improper Service
Due 31 July 2008
Resolved 5 November 2008
Resolution: Vessel was reinspected with new owners and item found to be corrected.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 25 July 2008 Resolved
Extinguishers were not serviced monthly.
Condition: Improper/Lack of Maintenance
Due 26 July 2008
Resolved 5 November 2008
Resolution: Vessel was reinspected with new owners and item found to be corrected.
Personnel › Training › Fire Fighting Basic
Issued 24 July 2008 Resolved
No proof of fire fighting training.
Condition: Unknown
Due 26 July 2008
Resolved 5 November 2008
Resolution: Vessel was reinspected with new owners and item found to be corrected.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 24 July 2008 Resolved
Vessel had no Discharge of Oil placard.
Condition: Unknown
Due 31 July 2008
Resolved 5 November 2008
Resolution: Vessel was reinspected with new owners and item found to be corrected.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 24 July 2008 Resolved
Transfer hose was not labeled tested or blanked.
Condition: Placed in Improper Service
Due 31 July 2008
Resolved 5 November 2008
Resolution: Vessel was reinspected with new owners and item found to be corrected.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.