LOW LAND 10 is a 1960 towing vessel. The Coast Guard has recorded 20 inspections since 1993, most recently in June 2026, along with 16 deficiencies and 4 casualty investigations between 2006 and 2023.

Records from 1993 to 2026. Most recent: inspection, 24 June 2026.

Built
1960
Last inspected
24 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 24 June 2026
…with no type recorded9
Operational controls None recorded without a removal date
Years with a record 16 calendar years (1993–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ6806
Flag
UNITED STATES
Maury page id
psix-77692

Documentation record

Registered dimensions (L × B × D)46.0 ft × 20.0 ft × 4.2 ft
Registered tonnagegross 25 / net 20
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLEVINGSTON SHPBLDG · ORANGE, TX, UNITED STATES · built 1960
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portHOUMA, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 14 May 2026 · expires 30 June 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it25 - Simplified, Gross Ton
20 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 8

Inspection history · 20

24 June 2026 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8413177
4 June 2025 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8149749
26 March 2024 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7829954
21 November 2023 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7828123
1 June 2023 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7778879
6 February 2023 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7700519
24 May 2022 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7458392
17 March 2021 Initial Certification
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7158084
10 December 2020 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7109768
13 February 2018 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6355235
1 August 2017 Deficiency Check · Industry Initiated Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6227009
31 January 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5934105
24 July 2014 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4936635
15 December 2009 Deficiency Check · Industry Initiated Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3650730
19 December 2006 Uninspected Other · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2843168
21 November 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2826512
25 October 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2825327
31 May 2001 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 1521797
11 April 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 173479
21 June 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 656222

Deficiency record · 16

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 June 2026 Resolved
Semi-Portable extinguisher out of hydro date.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2026
Resolved 14 July 2026
Resolution: 160-B replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 June 2026 Resolved
No drug testing program information on the vessel.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2026
Resolved 14 July 2026
Resolution: Program information placed on vessel.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 24 June 2026 Resolved
Valve at standpipe is made of plastic. Was not relaced in-kind with metal valve.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2026
Resolved 14 July 2026
Resolution: Plastic standpipe valve replace with metal valve.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 June 2026 Resolved
No current documentation of recent pressure relief valve testing on air recievers.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2026
Resolved 14 July 2026
Resolution: Valves tested.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 September 2025 Resolved
Each towing vessel certificated under the provisions of this subchapter must be in full compliance with the terms of the COI. Vessel was found operating commercially while not in full compliance with annual COI inspection.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 4 September 2025
Resolved 15 September 2025
Resolution: Vsl is now in compliance with COI.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 July 2025 Resolved
If the annual inspection reveals the need, the owner or managing operator must make any or all repairs or improvements within the time period specified by the OCMI. The OCMI may use Form CG-835, “Notice of Merchant Marine Inspection Requirements,” to record deficiencies discovered during the inspection. The OCMI will then give a copy of the completed form to the master of the vessel. Vessel failed to provide proof of deficiency corrections byt specified date on CG-835.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 5 July 2025
Resolved 15 September 2025
Resolution: Vsl made all appropriate repairs found from annual inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 June 2025 Resolved
A continuous supply of clean fuel must be provided to main propulsion engines. For the port and starboard main diesel engines, there were alarms indicating that water was in the fuel.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 July 2025
Resolved 5 June 2025
Resolution: Technician replaced faulty wiring on both MDEs.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 June 2025 Resolved
In the event of a serious marine incident, the marine employer is required to conduct testing within 2 hours of the incident of all individuals involved. Alcohol testing supplies were not present on board the vessel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2025
Resolved 5 June 2025
Resolution: Vessel procured alcohol testing strips.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 4 June 2025 Resolved
Testing for alarm set points are required to be completed twice every five years with no more than 3 years between each test. Testing of alarm set points on the engines were not being recorded and it has not been reported that they were done. 03SEP2025 Changed def. code to 60c
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 3 September 2025
Resolved 15 September 2025
Resolution: Received tech report for completion of required testing.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 4 June 2025 Resolved
Generators are required to have a gauge to indicate RPM. The starboard generator RPM indicator was found to be non-functioning. 03SEP2025 Changed def. code to 60c
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 3 September 2025
Resolved 15 September 2025
Resolution: Vessel replaced defective tachometer, provied photgraphic evidence of such.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 March 2021 Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is the only operating vessel in the fleet, and has not obtained a valid COI. A CG835V was issued by MSU Houma on 10DEC2020 authoring the vessel 90 days to obtain a CG COI. Prior to Movement, vessel is required to obtain a Coast Guard Certificate of Inspection (COI).
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 April 2021
Resolution: MSU Houma issued a Temp COI to the LOW LAND 5 meeting the 50% COI requirement for the company. The LOW LAND 10 is scheduled for a COI inspection 08 APR 2021.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 December 2020 Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is the only operating vessel in the fleet, and has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 90 days. If an inspection is not completed prior to this date, the action for this deficiency shall be changed to a 60(Rectify deficiencies prior to movement) and the vessel may no longer be permitted to operate.
Action required: 705 - Other - as specified
Due 10 March 2021
Resolved 17 March 2021
Resolution: Sector Corpus Christi issued a Prior to movement.
Fire Fighting › Fire Hoses › Condition
Issued 19 December 2006 Resolved
Fire hose inadequate as it was full of holes.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2006
Resolution: Fire hose was replaced prior to completion of examination.
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 19 December 2006 Resolved
Fire detection system not installed.
Due 19 January 2007
Resolved 4 January 2010
Resolution: Vessel was found with installed system
Fire Fighting › Remote Fuel Shutoff › General
Issued 19 December 2006 Resolved
Remote fuel shutoff not installed.
Due 19 January 2007
Resolved 4 January 2010
Resolution: Vessel was found with operating remote fuel shutoff.
Communications › Alarms/Indicators › General Alarm
Issued 19 December 2006 Resolved
General alarm not installed.
Due 19 January 2007
Resolved 4 January 2010
Resolution: Vessel was found with working general alarm

Casualty record · 4

25 October 2006Routine · role: Involved in a Marine Casualty · activity 2825327
31 January 2016Routine · role: Involved in a Marine Investigation (non-casualty) · activity 5934105
13 February 2018Routine · role: Involved in a Marine Casualty · activity 6355235
6 February 2023Routine · role: Sighted in Area · activity 7700519
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.