Inspection history · 47
4 June 2026
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8390985
20 March 2025
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8096442
27 March 2024
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7886002
7 April 2023
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7666398
6 February 2023
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7700519
18 May 2022
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7453971
15 April 2022
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7472171
5 February 2021
Administrative Inspection · Initial Certification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7136261
1 June 2015
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5141455
8 February 2013
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4530510
28 January 2013
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4524212
26 November 2012
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4490640
13 April 2012
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4286056
12 July 2010
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3793802
21 June 2010
Industry Initiated Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3772855
18 March 2007
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2889957
15 March 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2888736
26 February 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2878132
29 August 2006
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2764126
3 August 2006
MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2734830
29 December 2005
Type not recorded
No type recorded · USCG Heartland District (dpb) · USCG Heartland District (CGD-H) · Activity 2557639
22 April 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2490251
28 March 2005
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2322240
5 May 2004
Security Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2059748
9 January 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1982237
8 January 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1981988
7 January 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1982475
23 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978483
5 December 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1719797
4 December 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1717228
18 March 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1495953
25 January 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1484594
4 March 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 50011
4 March 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1487926
23 January 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 108614
28 March 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 474313
11 March 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 11606
9 December 1995
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 134540
31 March 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 162392
8 March 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 668718
8 March 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 709617
4 February 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 213171
4 February 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 213423
4 February 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 213453
4 October 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 668719
30 June 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 60660
8 October 1991
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 668720
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 February 2021
Resolved
A fixed fire pump must be capable of delivering water from the two highest hydrants . . . at a pilot-tube pressure of at least 50PSI and a flow rate of at least 80 gallons per minute.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 February 2021
Resolved 8 February 2021
Resolution: Fire pump was repaired and tested sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 February 2021
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid. The fuel filter for the starboard generator must have installed the required plug at the bottom end of the filter casing equipment.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 February 2021
Resolved 8 February 2021
Resolution: Installed plug, all sat
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 5 February 2021
Resolved
The remote fuel shutoff valve must be installed in the fuel piping directly outside of the fuel oil supply tank. The vessel must install a mechanism that allows for the shutoff valve directly outside the fuel tank to be operated remotely.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2021
Resolved 10 February 2021
Resolution: Yard installed valve and tested pull, all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 5 February 2021
Resolved
Closure devices must be provided for deckhouse hull penetrations, which open to the exterior of the vessel
and which may allow water to enter the vessel. Vessel
must ensure all doors/hatches to enter the machinery
space and the galley are watertight and/or weathertight,
as applicable for the space.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2021
Resolved 10 February 2021
Resolution: Removed door and made straight, installed and tested sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 February 2021
Resolved
Piping and machinery components that exceed 220 C, including . . . exhaust manifolds, and turbochargers, must be insulated. Vessel's exhaust manifolds on both generators were not properly insulated. vessel must have protective insulation installed around exposed areas of the exhaust manifold.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2021
Resolved 10 February 2021
Resolution: Installed exhaust wrap on all exposed parts.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 5 February 2021
Resolved
A record of the type, size, and service of each towline, face wire, and spring line, used to make the towing vessel fast to her tow, must be available to the Coast Guard or third-party auditor for review. The following minimum information is required in the record: The dates when examinations were performed, the identification of each item of towing gear examined, and the name(s) of the person(s) conducting the examinations.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2021
Resolved 12 March 2021
Resolution: Reviewed logs for history and accuracy. All new forms and logs are now in compliance.