MAURY USCG vessel records Sign in
← All vessels

CHRIS PIKE

CHRIS PIKE is a 2006 towing vessel. The Coast Guard has recorded 24 inspections since 2006, most recently in June 2026, along with 1 deficiency and 5 casualty investigations between 2008 and 2026.

Records from 2006 to 2026. Most recent: inspection, 10 June 2026.

Built
2006
Last inspected
10 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD2269
818086
Flag
UNITED STATES
367113150
Maury page id
psix-818086

Inspections, by type

…with no type recorded10
Years with a record 14 calendar years (2006–2026)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)85.8 ft × 32.0 ft × 10.0 ft
Registered tonnagegross 280 / net 177
ITC dimensions (L × B × D)85.8 ft × 32.0 ft × 10.0 ft
ITC tonnagegross 341 / net 102
BuilderEASTERN SHIPBUILDING GROUP INC · PANAMA CITY, FL, UNITED STATES · built 2006
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 November 2025 · expires 30 November 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it341 - Convention (Subpart B), Gross Ton
280 - Regulatory (Subpart C or D), Gross Ton
102 - Convention (Subpart B), Net Ton
177 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD2269MMSI 367113150 · active · compulsorily equipped · granted 18 February 2026, expires 10 May 2036
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 9

Inspection history · 24

10 June 2026 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8397277
10 June 2026 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8433660
14 October 2025 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8251748
26 August 2024 MTSA Verification · Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7953891
10 May 2024 Type not recorded
No type recorded · Station Freeport · USCG Heartland District (CGD-H) · Activity 7910228
9 January 2023 TPO Audit · Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7851509
20 October 2022 Type not recorded
No type recorded · Station Freeport · USCG Heartland District (CGD-H) · Activity 7583881
23 September 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7565071
22 April 2022 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7436242
22 April 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6942498
8 July 2019 Initial Certification · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6742033
9 May 2019 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6680666
9 May 2019 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6683070
7 August 2015 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5209748
1 October 2012 Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 4455039
17 April 2012 MTSA Verification · Industry Initiated Exam · MARPOL
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4288817
2 March 2010 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3688781
3 April 2009 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3445961
3 October 2008 Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3340139
26 September 2008 Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3341600
26 September 2008 Annual Inspection · MTSA Verification
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3341655
5 April 2007 Uninspected Other
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2902547
27 November 2006 MTSA Verification · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2829444
25 May 2006 Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2658769

Deficiency record · 1

Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 5 April 2007 Resolved
Install U.S.C.G. approved mounting brackets for all portable fire extinguishers as required by 46 CFR 25.30-5.
Action required: 705 - Other - as specified
Due 5 May 2007
Resolved 17 April 2012
Resolution: all portable fire extingushiers are mounted in proper brackets.

Casualty record · 5

26 September 2008Routine · role: Involved in a Marine Casualty · activity 3341600
3 October 2008Routine · role: Moored/Anchored in Vicinity of Primary Subject · serious marine incident, as classified · at L&D PEORIA · activity 3340139
3 April 2009Routine · role: Involved in a Marine Casualty · activity 3445961
9 May 2019Routine · role: Involved in a Marine Casualty · activity 6683070
10 June 2026Routine · role: Involved in a Marine Casualty · activity 8433660
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.