Records from 2007 to 2025. Most recent: inspection, 3 January 2025.
Documentation record
Registered dimensions (L × B × D)80.6 ft × 30.0 ft × 11.0 ft
Registered tonnagegross 266 / net 181
ITC dimensions (L × B × D)80.6 ft × 30.0 ft × 11.0 ft
ITC tonnagegross 301 / net 90
BuilderJOHN BLUDWORTH SHIPYARD LLC · CORPUS CHRISTI, TX, UNITED STATES · built 2007
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHOUSTON, TX
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 17 February 2026 · expires 28 February 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it90 - Convention (Subpart B), Net Ton
181 - Regulatory (Subpart C or D), Net Ton
301 - Convention (Subpart B), Gross Ton
266 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 29
3 January 2025
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8048633
7 December 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7836263
22 May 2023
Type not recorded
No type recorded · Station Freeport · USCG Heartland District (CGD-H) · Activity 7694294
6 January 2023
Appeal
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7644701
2 December 2022
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7603267
8 November 2021
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7347292
21 October 2020
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7081857
1 October 2020
Administrative Inspection · Initial Certification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7017653
17 October 2018
Type not recorded
No type recorded · Station Lake Charles · USCG Heartland District (CGD-H) · Activity 6563470
4 November 2017
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6308892
10 June 2016
MTSA Verification · Industry Initiated Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5913515
9 February 2016
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5812216
28 January 2015
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5060448
20 March 2014
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 4822518
21 June 2013
Industry Initiated Exam · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4629929
13 May 2013
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4590557
12 September 2011
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4143289
9 August 2011
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4110650
26 December 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3922651
30 July 2010
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3810326
17 July 2010
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3798015
20 May 2010
Industry Initiated Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3743063
17 January 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3665952
12 September 2009
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3592428
23 May 2009
Damage Survey
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3482680
4 March 2008
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3159685
24 July 2007
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3008197
18 July 2007
Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2999815
14 May 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2930477
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 December 2022
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards.
MI observed both port and starboard generators windings excessively coated in an oily residue. Owner/operator to provide documentation of generator cleaned and source of accumulation identified and repaired if necessary to the satisfaction of attending MI.
46CFR143.400(a)
60c.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 8 December 2022
Resolved 9 December 2022
Resolution: Provided report detailing replacement of rear seal and cleaning of generator windings. See documents.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 December 2022
Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. MI observed both fuel shutoff valves not operating as required when operated by vessel crew. Owner/operator is required to utilize valves with the ability to close via remote shutoff and provide documentation of completed action to
the satisfaction of attending MI.
46CFR143.260(b)
60c.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 8 December 2022
Resolved 9 December 2022
Resolution: Unit recieved video of the valves operating post repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 December 2022
Resolved
Repairs and minor alterations to existing towing vessels must be made in accordance with this part. New installations that are not replacements in kind must comply with the requirements of subpart C of this part, if applicable. MI observed a temporary power cord ran from an outlet in the steering gear space through the bulkhead in the fiddley space, across the overhead and continuing down the stbd bulkhead of the fiddley space servicing a chest freezer. Owner/operator is required to remove unauthorized alteration of non permanent wiring to the satisfaction of the attending MI.
46CFR143.205(d)
16c.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2022
Resolved 22 December 2022
Resolution: Vessel representative removed temporary power cord and relocated appliance.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 8 December 2022
Resolved
Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve. MI observed multiple distribution panels with unlabeled breakers. Owner/operator is required to label all breakers as per cite to the satisfaction of the attending MI.
46CFR143.300(d)
16c
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2022
Resolved 22 December 2022
Resolution: Unit recieved pictures of breakers labeled with location served.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 December 2022
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure the following: (a) All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. (b) Storage areas are kept free from accumulation of combustible and flammable materials insofar as practicable. MI observed fifteen pails of lubricating oil stored in the aft port side of the engine room in addition to the engine room bilge containing a significant amount of imulsified oil and water. Owner/operator is required to store flammable or combustible products in accordance with 46CFR142.255. The engine room bilge must be cleaned to the satisfaction of the attending MI and maintained in such condition.
46CFR142.220(a)(b)
16c.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2022
Resolved 22 December 2022
Resolution: Unit recieved pictures of the bilge post cleaning.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 8 December 2022
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space and must be either: (1) Automatic, battery-operated with a duration of no less than 2 hours; or (2) Non-electric, phosphorescent adhesive lighting strips that are installed along escape routes and sufficiently visible to enable egress with no power. MI observed the cited requirement isn't met in the crew berthing spaces. Owner/operator to comply with above cited reference.
46CFR143.410(b)
16c.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2022
Resolved 22 December 2022
Resolution: Unit recieved pictures of newly installed battle lanterns .
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 December 2022
Resolved
Electrical conductors passing though watertight bulkheads must be installed so that the bulkhead remains watertight. MI observed forward storage compartment wiring passing through the aft bulkhead with no watertight provisions. Owner/operator to seal bulkhead penetration to the satisfaction of the attending MI.
46CFR143.400
16c.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2022
Resolved 22 December 2022
Resolution: Unit recieved picture of cable penetration sealed.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 2 December 2022
Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. These devices must be suitable for the expected route. MI observed the forward deckhouse storage room stbd water tight door degraded at the lower portion not allowing for intended down flooding protection. Owner/operator to replace door with approved type and condition to the satisfaction of attending MI.
46CFR144.320(b)
50c.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2023
Resolved 22 December 2022
Resolution: Unit recieved pictures of repaired door.