MAURY USCG vessel records Sign in
← All vessels

CHEM 3702

CHEM 3702 is a 2007 tank barge. The Coast Guard has recorded 22 inspections since 2007, most recently in February 2026, along with 7 deficiencies and 2 casualty investigations between 2009 and 2022.

Records from 2007 to 2026. Most recent: inspection, 5 February 2026.

Built
2007
Last inspected
5 February 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

878041
Flag
UNITED STATES
—
Maury page id
psix-878041

Inspections, by type

…with no type recorded4
Years with a record 13 calendar years (2007–2026)
The 22 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFBOAT LLC · JEFFERSONVILLE, IN, UNITED STATES · built 2007
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portJEFFERSONVILLE, IN
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 May 2026 · expires 31 May 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 7

Inspection history · 22

5 February 2026 Examination of Repairs · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8306550
24 October 2022 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7614281
6 October 2022 Examination of Repairs · COI Inspection · MTSA Verification · Drydock Exam · Cargo Tank Internal · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7568752
11 August 2019 Bulk Liquid Transfer Monitor
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6779770
7 September 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6537828
24 August 2017 Drydock Exam · Internal Structural Exam · COI Inspection · Cargo Tank Internal · Deficiency Check · Examination of Repairs · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6249276
23 July 2015 MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5191092
6 December 2014 Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5037999
26 August 2013 Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4699014
14 August 2012 Examination of Repairs · MTSA Verification · COI Inspection · Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4410456
2 June 2010 Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3755623
13 February 2010 Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3679577
20 May 2009 Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3480115
18 May 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3479356
15 May 2009 Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3475444
5 February 2009 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3412975
4 February 2009 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3412864
31 January 2009 Damage Survey
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3403409
16 January 2009 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3395386
1 August 2008 Administrative Inspection
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 3305643
30 May 2008 MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3222332
27 July 2007 Hull Examination · MTSA Verification · Initial Certification · Internal Structural Exam · Cargo Tank Internal · Initial Construction-Excluding Oversight
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3009264

Deficiency record · 7

Construction/Loadline › Hull › Double Hull
Issued 31 August 2017 Resolved
Stern void newly installed K members upper and lower gap between members and cargo tanks not within 1 inch minimum tolerance. K members 3 & 4, port side.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 August 2017
Resolved 8 September 2017
Engineering › Diesel Engine (auxiliary) › Turbocharger
Issued 31 August 2017 Resolved
While running cargo prime mover, MI witnessed exhaust leak between turbo and exhaust piping.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 August 2017
Resolved 6 September 2017
Construction/Loadline › Hull › Weld
Issued 31 August 2017 Resolved
Repair all unsatisfatory welds (crack, perosity) in spaces marked by MI: STBD #1 wing void, STBD #2 wing void, STBD #4 wing void.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 August 2017
Resolved 6 September 2017
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 31 August 2017 Resolved
Provide documentation for cargo piping tests IAW CFR.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 August 2017
Resolved 6 September 2017
Construction/Loadline › Hull › Double Hull
Issued 24 August 2017 Resolved
Bow void newly installed K members upper and lower gap between members and cargo tank not within 1 inch minimum tolerance. K members 4 & 6, starboard side.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 August 2017
Resolved 6 September 2017
Electrical › Electric Supply System (service) › Cable
Issued 1 August 2008 Resolved
Electronically controlled engine not in compliance with 46 CFR 111.105.31( l). Vessel operator given until 01JAN09 to correct IAW D8 policy guidance 01-2008 and their approved company compliance plan. ACL compliance plan and D8 compliance plan approval letter have been scanned into vessel documents. For additional information see CG Central/Communities/Domestic Vessel Inspections (Flag State
Action required: 705 - Other - as specified
Due 1 January 2009
Resolved 16 January 2009
Resolution: Vessel changed to non-electronically controlled Cummins 6CTA8.3-DM Marine diesel engine. Installation and performance check satisfactory.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 27 July 2007 Resolved
Owner shall prove that cargo pump engine unit is in complete compliance with 46 CFR 111.105-31(l).
Action required: 705 - Other - as specified
Due 1 August 2008
Resolved 30 May 2008

Casualty record · 2

18 May 2009Routine · role: Involved in a Marine Casualty · activity 3479356
24 October 2022Routine · role: Involved in a Marine Casualty · activity 7614281
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.